Second-generation cryoballoon ablation for paroxysmal atrial fibrillation: Predictive role of atrial arrhythmias occurring in the blanking period on the incidence of late recurrences

Heart Rhythm ◽  
2016 ◽  
Vol 13 (4) ◽  
pp. 845-851 ◽  
Author(s):  
Giacomo Mugnai ◽  
Carlo de Asmundis ◽  
Burak Hünük ◽  
Erwin Ströker ◽  
Vedran Velagic ◽  
...  
2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Karapet V. Davtyan ◽  
Arpi H. Topchyan ◽  
Hakob A. Brutyan ◽  
Elena N. Kalemberg ◽  
Maria S. Kharlap ◽  
...  

Abstract Background Early recurrences of atrial arrhythmias (ERAA) after atrial fibrillation (AF) catheter ablation do not predict procedural failure. A well-demarcated homogeneous lesion delivered by cryoballoon is less arrhythmogenic, and the recommended three-months blanking period may not refer to cryoballoon ablation (CBA). Objective We aimed to evaluate the predictive role of ERAA after second-generation CBA using an implantable loop recorder. Methods This prospective observational study enrolled 100 patients (58 males, median age 58) with paroxysmal/persistent AF undergoing pulmonary vein (PV) CBA using second-generation cryoballoon with simultaneous ECG loop recorder implantation. The duration of follow-up was 12 months, with scheduled visits at 3, 6 and 12 months. Results 99 patients from 100 completed the 12-month follow-up period. ERAA occurred in 31.3 % of patients. 83.9 % of patients with ERAA also developed late recurrences. The 12-month freedom from AF in patients with ERAA was significantly lower than in those without ERAA (p < 0.0001). Non-paroxysmal AF and longer arrhythmia history were associated with increased risk of both early (HR 3.27; 95 % CI 1.32–8.08; p = 0.010 and HR 1.0147; 95 % CI 1.008–1.086; p = 0.015, respectively) and late recurrences (HR 3.89; 95 % CI 1.67–9.04; p = 0.002 and HR 1.0142; 95 % CI 1.007–1.078; p = 0.019, respectively) of AF. ERAA were another predictor for procedural failure (HR 15.2; 95 % CI (6.42–35.99; p = 0.019). Conclusions ERAA occurred in the third of the patients after PV second-generation CBA and are strongly associated with procedural failure. Longer duration of AF history and persistent AF are independent predictors of AF’s early and late recurrence.


2021 ◽  
Vol 77 (18) ◽  
pp. 324
Author(s):  
Abhishek Bose ◽  
Parag Anilkumar Chevli ◽  
Zeba Hashmath ◽  
Ajay K. Mishra ◽  
Gregory Berberian ◽  
...  

2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
K Ukita ◽  
A Kawamura ◽  
H Nakamura ◽  
K Yasumoto ◽  
M Tsuda ◽  
...  

Abstract Background Little has been reported on the outcome of contact force (CF)-guided radiofrequency catheter ablation (RFCA) and second generation cryoballoon ablation (CBA). Purpose The purpose of this study was to compare the outcome of CF-guided RFCA and second generation CBA for paroxysmal atrial fibrillation (PAF). Methods We enrolled the consecutive 364 patients with PAF who underwent initial ablation between September 2014 and July 2018 in our hospital. We compared the late recurrence of atrial tachyarrhythmia more than three months after ablation between RFCA group and CBA group. All RFCA procedures were performed using CF-sensing catheter and all CBA procedures were performed using second generation CB. Results There were significant differences in background characteristics: chronic kidney disease, serum brain natriuretic peptide level, and left ventricular ejection fraction. After propensity score matched analysis (Table), atrial tachyarrhythmia free survival was significantly higher in CBA group than in RFCA group (Figure). Conclusions Second generation CBA showed a significantly lower late recurrence rate compared to CF-guided RFCA. Kaplan-Meier Curve Funding Acknowledgement Type of funding source: None


2016 ◽  
Vol 27 (6) ◽  
pp. 677-682 ◽  
Author(s):  
VALENTINA DE REGIBUS ◽  
GIACOMO MUGNAI ◽  
DARRAGH MORAN ◽  
BURAK HÜNÜK ◽  
ERWIN STRÖKER ◽  
...  

2017 ◽  
Vol 49 (3) ◽  
pp. 329-335 ◽  
Author(s):  
Hugo-Enrique Coutiño ◽  
Juan-Pablo Abugattas ◽  
Moisés Levinstein ◽  
Giacomo Mugnai ◽  
Darragh Moran ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document