Dual chamber cardioverter-defibrillator used for His bundle pacing in patient with chronic atrial fibrillation

2015 ◽  
Vol 182 ◽  
pp. 395-398 ◽  
Author(s):  
Agnieszka Sławuta ◽  
Dariusz Biały ◽  
Joanna Moszczyńska-Stulin ◽  
Piotr Berkowski ◽  
Paweł Dąbrowski ◽  
...  
2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
A Ciesielski ◽  
A Slawuta ◽  
A Zabek ◽  
K Boczar ◽  
B Malecka ◽  
...  

Abstract   A single-chamber ICD is a standard method for primary SCD prophylaxis. In patients with chronic atrial fibrillation it does not contribute to the regularization of heart rate, which is crucial for proper treatment. Moreover, to avoid the deleterious effect of right ventricular pacing only minority of the patients with single chamber ICD get the appropriate, recommended dose of beta-blockers. The aim of our study was to assess the efficacy of direct His-bundle pacing in a population of patients with congestive heart failure and chronic atrial fibrillation using upgrade from single chamber to dual-chamber ICD and atrial channel to perform the His-bundle pacing Methods The study population included 39 patients (37 men, 2 women) aged 67.2±9.3 years, with CHF and chronic AF implanted primarily with single chamber ICD with established pharmacotherapy and stable clinical status. Results The echocardiography measurements at baseline and during follow-up were presented in the table: During short period (3–6 months) of follow-up the mean values of EF and LV dimensions significantly improved. This was also accompanied by functional status improvement. Conclusions His-bundle-based pacing in CHF-chronic AF patients contributes to significant echocardiographic and clinical improvement. Standard single-chamber ICD implantation in CHF-chronic AF patients yields only SCD prevention without influence on remodeling process. The physiological pacing contributes to better pharmacotherapy. Funding Acknowledgement Type of funding source: None


2019 ◽  
Vol 40 (Supplement_1) ◽  
Author(s):  
A Slawuta ◽  
K Boczar ◽  
A Zabek ◽  
A Ciesielski ◽  
J Hiczkiewicz ◽  
...  

Abstract The heart rate regularization is crucial for proper treatment of patients with atrial fibrillation and congestive heart failure. The standard resynchronization can be applied, but in patients with narrow QRS this procedure is of no use. The aim of our study is to assess the efficacy of direct His-bundle pacing in patients with congestive heart failure and chronic atrial fibrillation using dual chamber ICD implanted for prevention of sudden cardiac death. Methods The study population included 78 patients with CHF and chronic AF: group A - 56 pts treated with direct His-bundle pacing using atrial port of dual chamber ICD and group B - 22 patients implanted with single chamber ICD as recommended by the guidelines. The patients in group B constituting clinical controls were derived from the Heart Failure Outpatients Clinic with established clinical status and pharmacotherapy. Results The demographic data, clinical characteristics and echocardiography measurements at baseline and during follow-up were presented in the table: Table 1 Group A Group B P value Age (years) 69.7±6.9 66.7±11.3 n.s. Sex (% of male sex) 84.0 86.4 n.s. Ventricular pacing (%) – 46.3±31.2 – His-bundle pacing (%) 81.7±9.2 – – pre post pre post pre vs. post LVEDD (mm) 66.9±4.9 59.9±4.7 64.8±8.0 64.7±8.1 <0.01 n.s. EF (%) 29.6±3.8 43.6±5.9 28.1±6.1 28.8±7.3 <0.01 n.s. NYHA class 2.7±0.6 1.4±0.6 2.5±0.6 2.0±0.2 <0.05 n.s. B-blocker dose (metoprolol equivalent dose) 104.6±41.6 214.3±82.6 78.3±56.6 103.1±49.2 <0.001 <0.05 During 12-months of follow-up the mean values of NYHA functional class, EF and LV dimensions did not change in group B but significantly improved in group A. The physiological His-bundle based pacing enabled optimal beta-blocker dosing. The studied groups had no tachyarrhythmia at baseline so the presumable atrial fibrillation-related harm depends on the rhythm irregularity. Conclusions His-bundle-based pacing in CHF-chronic AF patients contributes to significant echocardiographic and clinical improvement. Standard single-chamber ICD implantation in CHF-chronic AF patients yields only SCD prevention without influence on remodeling process. The CHF-patients with narrow QRS and chronic AF benefit from substantially higher beta-blockade which can be instituted in His-bundle pacing group.


2019 ◽  
Vol 40 (Supplement_1) ◽  
Author(s):  
A Ciesielski ◽  
A Slawuta ◽  
K Boczar ◽  
A Zabek ◽  
B Malecka ◽  
...  

Abstract A single-chamber ICD is a standard method for primary SCD prophylaxis. In patients with chronic atrial fibrillation it dose not contribute to the regularization of heart rate, which is crucial for proper treatment. The aim of our study was to assess the efficacy of direct His-bundle pacing in patients with congestive heart failure and chronic atrial fibrillation using upgrade from single chamber to dual-chamber ICD. Methods The study population included 21 patients with CHF and chronic AF implanted primarily with single chamber ICD with etablished pharmacotherapy and stable clinical status. Results The echocardiography measurements at baseline and during ollow-up were presented in the table: Table 1 Baseline Follow-up p-value LVEDD (ms) 67.7±10.7 64.5±8.6 <0.05 EF (%) 27.0±4.8 33.2±6.9 <0.05 NYHA class 2.8±0.6 1.9±0,5 <0.05 During short 4-months of follow-up the mean values of EF and LV dimensions significantly improved. This was also accompanied by functional status improvement. Conclusions His-bundle-based pacing in CHF-chronic AF patients contributes to significant echocardiographic and clinical improvement. Standard single-chamber ICD implantation in CHF-chronic AF patients yields only SCD prevention without influence on remodeling process.


EP Europace ◽  
2012 ◽  
Vol 15 (1) ◽  
pp. 83-88 ◽  
Author(s):  
Rafael Barba-Pichardo ◽  
Ana Manovel Sánchez ◽  
Juan M. Fernández-Gómez ◽  
Pablo Moriña-Vázquez ◽  
José Venegas-Gamero ◽  
...  

Circulation ◽  
2015 ◽  
Vol 132 (suppl_3) ◽  
Author(s):  
Brian Olshansky ◽  
Mark Richards ◽  
Arjun D Sharma ◽  
Paul W Jones ◽  
Nicholas Wold ◽  
...  

Introduction: Recent remote follow-up data analysis suggests that Lower Rate Limit (LRL) programming at 40 beats per minute (bpm) is associated with lower mortality than higher LRL in patients receiving cardiac resynchronization defibrillators (CRT-d) devices. Purpose: We evaluated: 1. if LRL programming in CRT-d devices is based on implanting center or if it varies from patient-to-patient within centers and 2. if LRL programming is associated with survival. Method: The ALTITUDE remote follow-up database was analyzed for dual-chamber CRT-d devices implanted 2006-2011. LRL programming near implant was assessed. Patients were included if LRL remained constant during follow-up. Centers were included with >25 implants. Mortality was determined from the Social Security Death Index. Results: Of 64,482 patients receiving CRT-d devices (not in chronic atrial fibrillation), 56,501 were from centers implanting >25 devices. Of these, 4,683 were implanted in centers where most patients (>75%) received the same LRL (homogeneous); 51,818 were implanted in centers with variable LRL programming (heterogeneous). No difference in overall survival existed between the two approaches to LRL programming. However, in centers that varied LRL programming, LRL<60 bpm was associated with better 5-year survival (p<0.001) (figure). Conclusion: Most patients in the ALTITUDE database received CRT-D devices from centers that vary LRL programming. At these centers, LRL <60 bpm programming is associated with better survival but the mechanism of benefit is unknown. Alternatively, LRL <60 bpm programming for all patients does not confer survival benefit.


Sign in / Sign up

Export Citation Format

Share Document