Addition of copeptin improves diagnostic performance of point-of-care testing (POCT) for cardiac troponin T in early rule-out of myocardial infarction — A pilot study

2015 ◽  
Vol 198 ◽  
pp. 26-30 ◽  
Author(s):  
Mehrshad Vafaie ◽  
Moritz Biener ◽  
Matthias Mueller ◽  
Haitham Abu Sharar ◽  
Oliver Hartmann ◽  
...  
2015 ◽  
Vol 187 (8) ◽  
pp. E243-E252 ◽  
Author(s):  
Tobias Reichlin ◽  
Raphael Twerenbold ◽  
Karin Wildi ◽  
Maria Rubini Gimenez ◽  
Nathalie Bergsma ◽  
...  

1999 ◽  
Vol 84 (11) ◽  
pp. 1281-1286 ◽  
Author(s):  
E.Magnus Ohman ◽  
Paul W Armstrong ◽  
Harvey D White ◽  
Christopher B Granger ◽  
Robert G Wilcox ◽  
...  

2019 ◽  
Vol 9 (1) ◽  
pp. 14-22 ◽  
Author(s):  
M Arslan ◽  
A Dedic ◽  
E Boersma ◽  
EA Dubois

Aims: The purpose of this study was to determine (a) the ability of serial high-sensitivity cardiac troponin T measurements to rule out acute myocardial infarction and (b) the ability of a single high baseline high-sensitivity cardiac troponin T measurement to rule in acute myocardial infarction in patients presenting to the emergency department with acute chest pain. Methods and results: Embase, Medline, Cochrane, Web of Science and Google scholar were searched for prospective cohort studies that evaluated parameters of diagnostic accuracy of serial high-sensitivity cardiac troponin T to rule out acute myocardial infarction and a single baseline high-sensitivity cardiac troponin T value>50 ng/l to rule in acute myocardial infarction. The search yielded 21 studies for the systematic review, of which 14 were included in the meta-analysis, with a total of 11,929 patients and an overall prevalence of acute myocardial infarction of 13.0%. For rule-out, six studies presented the sensitivity of serial measurements <14 ng/l. This cut-off classified 60.1% of patients as rule-out and the summary sensitivity was 96.7% (95% confidence interval: 92.3–99.3). Three studies presented the sensitivity of a one-hour algorithm with a baseline high-sensitivity cardiac troponin T value<12 ng/l and delta 1 hour <3 ng/l. This algorithm classified 60.2% of patients as rule-out and the summary sensitivity was 98.9% (96.4–100). For rule-in, six studies reported the specificity of baseline high-sensitivity cardiac troponin T value>50 ng/l. The summary specificity was 94.6% (91.5–97.1). Conclusion: Serial high-sensitivity cardiac troponin T measurement strategies to rule out acute myocardial infarction perform well, and a single baseline high-sensitivity cardiac troponin T value>50 ng/l to rule in acute myocardial infarction has a high specificity.


2017 ◽  
Vol 8 (4) ◽  
pp. 299-308 ◽  
Author(s):  
Martin B Rasmussen ◽  
Carsten Stengaard ◽  
Jacob T Sørensen ◽  
Ingunn S Riddervold ◽  
Troels M Hansen ◽  
...  

Objective: The purpose of this study was to determine the predictive value of routine prehospital point-of-care cardiac troponin T measurement for diagnosis and risk stratification of patients with suspected acute myocardial infarction. Methods and results: All prehospital emergency medical service vehicles in the Central Denmark Region were equipped with a point-of-care cardiac troponin T device (Roche Cobas h232) for routine use in all patients with a suspected acute myocardial infarction. During the study period, 1 June 2012–30 November 2015, prehospital point-of-care cardiac troponin T measurements were performed in a total of 19,615 cases seen by the emergency medical service and 18,712 point-of-care cardiac troponin T measurements in 15,781 individuals were matched with an admission. A final diagnosis of acute myocardial infarction was confirmed in 2187 cases and a total of 2150 point-of-care cardiac troponin T measurements (11.0%) had a value ≥50 ng/l, including 966 with acute myocardial infarction (sensitivity: 44.2%, specificity: 92.8%). Patients presenting with a prehospital point-of-care cardiac troponin T value ≥50 ng/l had a one-year mortality of 24% compared with 4.8% in those with values <50 ng/l, log-rank: p<0.001. The following variables showed the strongest association with mortality in multivariable analysis: point-of-care cardiac troponin T≥50 ng/l (hazard ratio 2.10, 95% confidence interval: 1.90–2.33), congestive heart failure (hazard ratio 1.93, 95% confidence interval: 1.74–2.14), diabetes mellitus (hazard ratio 1.42, 95% confidence interval: 1.27–1.59) and age, one-year increase (hazard ratio 1.08, 95% confidence interval: 1.08–1.09). Conclusions: Patients with suspected acute myocardial infarction and a prehospital point-of-care cardiac troponin T ≥50 ng/l have a poor prognosis irrespective of the final diagnosis. Routine troponin measurement in the prehospital setting has a high predictive value and can be used to identify high-risk patients even before hospital arrival so that they may be re-routed directly for advanced care at an invasive centre.


Sign in / Sign up

Export Citation Format

Share Document