The temperature and pressure jumps at the vapor–liquid interface: Application to a two-phase cooling system

Author(s):  
Elizaveta Ya. Gatapova ◽  
Irina A. Graur ◽  
Felix Sharipov ◽  
Oleg A. Kabov
1983 ◽  
Author(s):  
S. Ollendorf ◽  
F. A. Costello

Author(s):  
Oyuna Angatkina ◽  
Andrew Alleyne

Two-phase cooling systems provide a viable technology for high–heat flux rejection in electronic systems. They provide high cooling capacity and uniform surface temperature. However, a major restriction of their application is the critical heat flux condition (CHF). This work presents model predictive control (MPC) design for CHF avoidance in two-phase pump driven cooling systems. The system under study includes multiple microchannel heat exchangers in series. The MPC controller performance is compared to the performance of a baseline PI controller. Simulation results show that while both controllers are able to maintain the two-phase cooling system below CHF, MPC has significant reduction in power consumption compared to the baseline controller.


1983 ◽  
Author(s):  
Robert H. Hamasaki ◽  
Janet L. Abe ◽  
James L. Franklin

2021 ◽  
Author(s):  
Jackson Braz Marcinichen ◽  
Raffaele Luca Amalfi ◽  
Filippo Cataldo ◽  
John Richard Thome

2019 ◽  
Vol 163 ◽  
pp. 114338 ◽  
Author(s):  
Fengze Hou ◽  
Wenbo Wang ◽  
Hengyun Zhang ◽  
Cheng Chen ◽  
Chuan Chen ◽  
...  

1992 ◽  
Vol 114 (3) ◽  
pp. 290-299 ◽  
Author(s):  
C. O. Gersey ◽  
I. Mudawar

Boiling experiments were performed with FC-72 on a series of nine in-line simulated microelectronic chips in a flow channel to ascertain the effects of channel orientation on critical heat flux (CHF). The simulated chips, measuring 10 mm × 10 mm, were flush-mounted to one wall of a 20 mm × 5 mm flow channel. The channel was rotated in increments of 45 degrees through 360 degrees such that the chips were subjected to coolant in upflow, downflow, or horizontal flow with the chips on the top or bottom walls of the channel with respect to gravity. Flow velocity was varied between 13 and 400 cm/s for subcoolings of 3, 14, 25, and 36°C and an inlet pressure of 1.36 bar. While changes in angle of orientation produced insignificant variations in the single-phase heat transfer coefficient, these changes had considerable effects on the boiling pattern in the flow channel and on CHF for velocities below 200 cm/s,’ with some chips reaching CHF at fluxes as low as 18 percent of those corresponding to vertical upflow. Increased subcooling was found to slightly dampen this adverse effect of orientation. The highest CHF values were measured with near vertical upflow and/or upward-facing chips, while the lowest values were measured with near vertical downflow and/or downward-facing chips. These variations in CHF were attributed to differences in flow boiling regime and vapor layer development on the surfaces of the chips between the different orientations. The results of the present study reveal that, while some flexibility is available in the packaging of multi-chip modules in a two-phase cooling system, some orientations should always be avoided.


Author(s):  
Tie Jun Zhang ◽  
Yoav Peles ◽  
John T. Wen ◽  
Michael K. Jensen

Because of increasing power densities, refrigeration systems are being explored for two-phase cooling of ultra high power electronic components. Flow instabilities are potential problems in any two-phase refrigeration cooling system especially in transient applications. Oscillatory two-phase flow in a boiling channel can trigger transition to the critical heat flux (CHF). Active control methods can help better dynamic thermal management of electronic systems, even though transient two-phase boiling flow mechanisms are complicated. This paper presents a framework for the transient analysis and active control of pressure-drop flow instabilities under varying imposed heat loads. The first part of the paper is to study the external effects on boiling flow characteristics and the boiling oscillatory flow responses to transient heat load changes. Then based on the theoretical analysis of boiling flow oscillations, a set of active control schemes are developed and studied to suppress flow oscillations and, therefore, to increase the CHF. With the available control devices (i.e., inlet valve and supply pump), different active control schemes are studied to improve the transient two-phase cooling performance. Finally, a discussion is included to address potential future research.


2012 ◽  
Vol 41 ◽  
pp. 36-51 ◽  
Author(s):  
Jackson Braz Marcinichen ◽  
Jonathan Albert Olivier ◽  
John Richard Thome

Sign in / Sign up

Export Citation Format

Share Document