CO2 reduction on Cu/C used as a cathode in a polymeric electrolyte reactor - Fuel cell type

Author(s):  
Mariana Lima ◽  
Camila M. Godoi ◽  
Monique C.L. Santos ◽  
Julio Nandenha ◽  
Almir O. Neto ◽  
...  
ACS Omega ◽  
2020 ◽  
Vol 5 (26) ◽  
pp. 16003-16009 ◽  
Author(s):  
Luis M. S. Garcia ◽  
Sanil Rajak ◽  
Khaoula Chair ◽  
Camila M. Godoy ◽  
Araceli Jardim Silva ◽  
...  

2009 ◽  
Vol 30 (4) ◽  
pp. 329-336 ◽  
Author(s):  
Mia Kim ◽  
Moon Sik Hyun ◽  
Geoffrey M. Gadd ◽  
Gwang Tae Kim ◽  
Sang‐Joon Lee ◽  
...  

2004 ◽  
Vol 63 (6) ◽  
pp. 672-681 ◽  
Author(s):  
B. H. Kim ◽  
H. S. Park ◽  
H. J. Kim ◽  
G. T. Kim ◽  
I. S. Chang ◽  
...  

2011 ◽  
Vol 9 (2) ◽  
pp. 679-683 ◽  
Author(s):  
K. Mochizuki ◽  
A. Yamamoto ◽  
T. Kikuchi ◽  
M. Sudoh ◽  
Y. Gomi ◽  
...  

2013 ◽  
Vol 68 (9) ◽  
pp. 1914-1919 ◽  
Author(s):  
Gai-Xiu Yang ◽  
Yong-Ming Sun ◽  
Xiao-Ying Kong ◽  
Feng Zhen ◽  
Ying Li ◽  
...  

Microbial fuel cells (MFCs) are devices that exploit microorganisms as biocatalysts to degrade organic matter or sludge present in wastewater (WW), and thereby generate electricity. We developed a simple, low-cost single-chamber microbial fuel cell (SCMFC)-type biochemical oxygen demand (BOD) sensor using carbon felt (anode) and activated sludge, and demonstrated its feasibility in the construction of a real-time BOD measurement system. Further, the effects of anodic pH and organic concentration on SCMFC performance were examined, and the correlation between BOD concentration and its response time was analyzed. Our results demonstrated that the SCMFC exhibited a stable voltage after 132 min following the addition of synthetic WW (BOD concentration: 200 mg/L). Notably, the response signal increased with an increase in BOD concentration (range: 5–200 mg/L) and was found to be directly proportional to the substrate concentration. However, at higher BOD concentrations (>120 mg/L) the response signal remained unaltered. Furthermore, we optimized the SCMFC using synthetic WW, and tested it with real WW. Upon feeding real WW, the BOD values exhibited a standard deviation from 2.08 to 8.3% when compared to the standard BOD5 method, thus demonstrating the practical applicability of the developed system to real treatment effluents.


1997 ◽  
Vol 8 (1-3) ◽  
pp. 1077-1081 ◽  
Author(s):  
Leonid Rabinovich ◽  
Jenny Gun ◽  
Michael Tsionsky ◽  
Ovadia Lev
Keyword(s):  

2005 ◽  
Vol 106 (1) ◽  
pp. 35-42 ◽  
Author(s):  
W KIATKITTIPONG ◽  
T TAGAWA ◽  
S GOTO ◽  
S ASSABUMRUNGRAT ◽  
P PRASERTHDAM

2002 ◽  
Vol 5 (2) ◽  
pp. H1 ◽  
Author(s):  
Atsuko Hashimoto ◽  
Takashi Hibino ◽  
Mitsuru Sano
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document