Correction of FTIR acquired photodetector response spectra from mid-infrared to visible bands using onsite measured instrument function

2018 ◽  
Vol 92 ◽  
pp. 78-83 ◽  
Author(s):  
Yong-gang Zhang ◽  
Xiu-mei Shao ◽  
Yi-nan Zhang ◽  
Yi Gu ◽  
Xing-you Chen ◽  
...  
2005 ◽  
Vol 14 ◽  
pp. 337-342 ◽  
Author(s):  
M. Dolci ◽  
G. Valentini ◽  
O. Straniero ◽  
G. Di Rico ◽  
M. Ragni ◽  
...  

2018 ◽  
Author(s):  
Y. H. Kan ◽  
Changying Zhao ◽  
Zhuomin M. Zhang

2011 ◽  
Vol 28 (1) ◽  
pp. 33-48 ◽  
Author(s):  
Oto Hanuš ◽  
Václava Genčurová ◽  
Yunhai Zhang ◽  
Pavel Hering ◽  
Jaroslav Kopecký ◽  
...  

Milk acetone determination by the photometrical method after microdiffusion and via FT infra-red spectroscopyMilk acetone (AC) and betahydroxybutyrate (BHB) are important indicators of the energy metabolism of cows (ketosis occurrence) and an effective method for their determination, with reliable results, is of great importance. The goal of this work was to investigate the infrared method MIR-FT in terms of its calibration for milk AC and to develop a usable procedure. The microdiffusion photometric (485 nm; Spekol 11) method was used with salicylaldehyde as a reference (Re) and mid infrared spectroscopy FT (MIR-FT: Lactoscope FT-IR, Delta; MilkoScan FT 6000, M-Sc) as an indirect method. The acetone addition to milk had no recovery using MIR-FT (Delta). The reference AC set must have acceptable statistics for good MIR-FT calibration (M-Sc) and they were: 10.1 ± 9.74 at a geometric mean of 7.26 mg l-1, and a variation range from 1.98 to 33.66 mg l-1. The AC correlation between Re and MIR-FT (Delta) was low at 0.32 (P>0.05 but the Log AC relationship between Re and MIR-FT (M-Sc) was markedly better at 0.80 (P<0.01). The conversion of >10 mg l-1 as an AC subclinical ketosis limit could be > -0.80 (feedback 0.158 mmol l-1 = 9.25 mg l-1) and > -1.66. This could be important for ketosis monitoring (using M-Sc).


Author(s):  
Nikita Chernukha

The article is about nuclear power plant (NPP) safety analysis in case of aircraft crash. Specifically, the article considers the following problems: inclusion of aircraft crash into NPP design bases regarding calculation of frequency of an aircraft crash into NPP; aspects of justification of loads on NPP structures, systems and components (SSCs) caused by mechanical action of a primary missile – aircraft fuselage impact. Probabilistic characteristics of such random parameters as frequency of aircraft crash and direction of aircraft trajectory are determined by the results of analysis of world statistics of aviation accidents. Method of calculation of aircraft crash frequency on structures, buildings and NPP as a whole is presented. It takes into account options of accidental and intentional aircraft crashes and various aircraft approach scenarios. Procedure of probabilistic justification of loads on civil structures under aircraft impact is described. The loads are specified so as not to exceed allowable value of failure probability of NPP as a whole. Calculation of failure frequency of civil structures of existing NPP is given as an example to show analysis in case of a crash of an aircraft heavier than considered in NPP design. Procedure of probabilistic justification of dynamic loads on NPP equipment in case of aircraft impact is described. Method of floor response spectra (FRS) calculation with the required non-exceedance probability is given. Probabilistically justified loads in case of intentional aircraft impact (act of terrorism) are also considered. Additionally it is presented how internal forces calculated with the use of FRS with the required non-exceedance probability can be summed to provide analysis of subsystems.


Sign in / Sign up

Export Citation Format

Share Document