Fe87Zr7B4Co2 amorphous alloy with excellent magneto-caloric effect near room temperature

2018 ◽  
Vol 95 ◽  
pp. 85-88 ◽  
Author(s):  
P. Yu ◽  
J.Z. Zhang ◽  
L. Xia
2016 ◽  
Vol 658 ◽  
pp. 598-602 ◽  
Author(s):  
Z.W. Wang ◽  
P. Yu ◽  
Y.T. Cui ◽  
L. Xia

2009 ◽  
Vol 478 (1-2) ◽  
pp. 566-571 ◽  
Author(s):  
P. Nisha ◽  
P.N. Santhosh ◽  
K.G. Suresh ◽  
C. Pavithran ◽  
Manoj Raama Varma

Author(s):  
В.А. Рыжов ◽  
Б.Т. Мелех ◽  
Л.П. Казакова

Abstract Infrared absorption spectra of chalcogenide alloys of the GST system with the compositions Ge14Sb29Te57 and Ge15Sb15Te70 in the amorphous and crystalline state were measured and analyzed in the range of 20 – 400 cm– 1 (0.6 – 12 THz) at room temperature. Absorption at these frequencies is due to the manifestation of correlated torsional vibrations of structural units of the amorphous alloy and phonon modes of the crystal. The performed assignment of absorption bands and the revealed differences in the IR spectra make it possible to more confidently represent the possible molecular mechanism of reversible amorphous-crystalline transformations in the studied phase-changing materials


2008 ◽  
Vol 92 (15) ◽  
pp. 151906 ◽  
Author(s):  
Sang-Chul Lee ◽  
Chang-Myeon Lee ◽  
Jae-Chul Lee ◽  
Hwi-Jun Kim ◽  
Yoji Shibutani ◽  
...  

2011 ◽  
Vol 291-294 ◽  
pp. 65-71 ◽  
Author(s):  
Qing Jun Chen ◽  
Lin Li Hu ◽  
Xian Liang Zhou ◽  
Xiao Zhen Hua ◽  
Ying Jun Yang

The purpose of this study is to investigate the electrochemical properties of Fe44Cr16Mo16C18B6amorphous alloy coating fabricated using high velocity oxygen fuel (HVOF) technology in 2.0M HCl and NaOH solution at room temperature(25°C). Based on the potentiodynamic polarization curves and Electrochemical Impedance Spectroscopy(EIS) testing results of coating in aqueous solutions of HCl and NaOH, the corrosion resistance of Fe44Cr16Mo16C18B6amorphous alloy coating in HCl solution was superior to that in NaOH solution. The icorrwas 1.487×10-5A·cm-2in HClsolution and 1.107×10-4A·cm-2in NaOH solution, while the Rtreach to 5.789×104Ω·cm2and 9780Ω·cm2, respectively. On the other hand, these corrosion phenomenon could be better interpreted by R(Q(R(RQW)))(RL) and R(RL)(Q(R(CW))) equivalent circuit model, which were different from that of other Fe-based amorphous alloys in HCl and NaOH solution, respectively.


2019 ◽  
Vol 125 (8) ◽  
pp. 085302 ◽  
Author(s):  
Rajkumar Modak ◽  
Ananthakrishnan Srinivasan

2009 ◽  
Vol 404 (16) ◽  
pp. 2495-2498 ◽  
Author(s):  
M.S. Islam ◽  
D.T. Hanh ◽  
F.A. Khan ◽  
M.A. Hakim ◽  
D.L. Minh ◽  
...  

2014 ◽  
Vol 105 (11) ◽  
pp. 112907 ◽  
Author(s):  
Sanjay Kumar Upadhyay ◽  
V. Raghavendra Reddy ◽  
Pallab Bag ◽  
R. Rawat ◽  
S. M. Gupta ◽  
...  

2016 ◽  
Vol 22 (1) ◽  
pp. 26-29 ◽  
Author(s):  
Rajkumar Modak ◽  
. B. Deka ◽  
M. Manivel Raja ◽  
. A. Srinivasan

Sign in / Sign up

Export Citation Format

Share Document