scholarly journals The Relationship of Left Ventricular Trabeculation to Ventricular Function and Structure Over a 9.5-Year Follow-Up

2014 ◽  
Vol 64 (19) ◽  
pp. 1971-1980 ◽  
Author(s):  
Filip Zemrak ◽  
Mark A. Ahlman ◽  
Gabriella Captur ◽  
Saidi A. Mohiddin ◽  
Nadine Kawel-Boehm ◽  
...  
2009 ◽  
Vol 11 (S1) ◽  
Author(s):  
Al-Hakim Ramsey ◽  
Michael C Fishbein ◽  
Thomas O'Donnell ◽  
James Sayre ◽  
Kalyanam Shivkumar ◽  
...  

2016 ◽  
Vol 35 (2) ◽  
pp. 130-136 ◽  
Author(s):  
Ivana Petrovic ◽  
Ivan Stankovic ◽  
Goran Milasinovic ◽  
Gabrijela Nikcevic ◽  
Bratislav Kircanski ◽  
...  

SummaryBackground:In the majority of patients with a wide QRS complex and heart failure resistant to optimal medical therapy, cardiac resynchronization therapy (CRT) leads to rever se ventricular remodeling and possibly to changes in cardiac collagen synthesis and degradation. We investigated the relationship of biomarkers of myocardial collagen meta bolism and volumetric response to CRT.Methods:We prospectively studied 46 heart failure patients (mean age 61±9 years, 87% male) who underwent CRT im plantation. Plasma concentrations of amino-terminal pro peptide type I (PINP), a marker of collagen synthesis, and carboxy-terminal collagen telopeptide (CITP), a marker of collagen degradation, were measured before and 6 months after CRT. Response to CRT was defined as 15% or greater reduction in left ventricular end-systolic volume at 6-month follow-up.Results:Baseline PINP levels showed a negative correlation with both left ventricular end-diastolic volume (r=−0.51; p=0.032), and end-systolic diameter (r=−0.47; p=0.049). After 6 months of device implantation, 28 patients (61%) responded to CRT. No significant differences in the base-line levels of PINP and CITP between responders and nonresponders were observed (p>0.05 for both). During follow-up, responders demonstrated a significant increase in serum PINP level from 31.37±18.40 to 39.2±19.19 μg/L (p=0.049), whereas in non-responders serum PINP levels did not significantly change (from 28.12±21.55 to 34.47±18.64 μg/L; p=0.125). There were no significant changes in CITP levels in both responders and non-responders (p>0.05).Conclusions:Left ventricular reverse remodeling induced by CRT is associated with an increased collagen synthesis in the first 6 months of CRT implantation.


2006 ◽  
Vol 8 (5) ◽  
pp. 389 ◽  
Author(s):  
Ghada M. M. Shahin ◽  
Geert J. M. G. van der Heijden ◽  
Michiel L. Bots ◽  
Maarten-Jan Cramer ◽  
Wybren Jaarsma ◽  
...  

<P>Objective: To evaluate clinical and echocardiographic outcomes for the semi-flexible Carpentier-Edwards Physio and the rigid Classic mitral annuloplasty ring. </P><P>Methods: Ninety-six patients were randomized for either a Classic (n = 53) or a Physio (n = 43) ring from October 1995 through July 1997. Mean follow-up was 5.1 years (range .1-6.6). We included standard patient characteristics at baseline and during follow-up. Analyses were adjusted for age and gender, and for factors that differed across groups at baseline. In 2002, echocardiography was performed in 74% of the survivors. </P><P>Results: We found a 16% difference in mortality: 14% in the Physio group (n = 6) and 30% in the Classic group (n = 16) (adjusted P = .41). Life table analysis shows that the absolute risk of death after 30 months is lower in the Physio group. Intra-operative repair failure occurred in 3 patients (6%) of the Classic group, and in 4 (9%) of the Physio group, resulting in mitral valve replacement. Late failure occurred in 1 patient (2%) in the Classic group, and in 4 (9%) in the Physio group. At follow-up, left ventricular function did not differ across groups (ejection fraction 45% and 48% (adjusted P = .65)). The combined NYHA class III-IV had improved for the Classic group in 42% and for the Physio group in 34%. </P><P>Conclusion: Although the 16% difference in mortality did not reach statistical significance, it is considered clinically important. No differences in morbidity, valve function, and left ventricular function were found. Further research to explain the difference in mortality is required.</P>


2020 ◽  
Author(s):  
Ananta Addala ◽  
Marie Auzanneau ◽  
Kellee Miller ◽  
Werner Maier ◽  
Nicole Foster ◽  
...  

<b>Objective:</b> As diabetes technology use in youth increases worldwide, inequalities in access may exacerbate disparities in hemoglobin A1c (HbA1c). We hypothesized an increasing gap in diabetes technology use by socioeconomic status (SES) would be associated with increased HbA1c disparities. <p> </p> <p><b>Research Design and Methods: </b>Participants aged <18 years with diabetes duration ≥1 year in the Type 1 Diabetes Exchange (T1DX, US, n=16,457) and Diabetes Prospective Follow-up (DPV, Germany, n=39,836) registries were categorized into lowest (Q1) to highest (Q5) SES quintiles. Multiple regression analyses compared the relationship of SES quintiles with diabetes technology use and HbA1c from 2010-2012 and 2016-2018. </p> <p> </p> <p><b>Results: </b>HbA1c was higher in participants with lower SES (in 2010-2012 & 2016-2018, respectively: 8.0% & 7.8% in Q1 and 7.6% & 7.5% in Q5 for DPV; and 9.0% & 9.3% in Q1 and 7.8% & 8.0% in Q5 for T1DX). For DPV, the association between SES and HbA1c did not change between the two time periods, whereas for T1DX, disparities in HbA1c by SES increased significantly (p<0.001). After adjusting for technology use, results for DPV did not change whereas the increase in T1DX was no longer significant.</p> <p> </p> <p><b>Conclusions: </b>Although causal conclusions cannot be drawn, diabetes technology use is lowest and HbA1c is highest in those of the lowest SES quintile in the T1DX and this difference for HbA1c broadened in the last decade. Associations of SES with technology use and HbA1c were weaker in the DPV registry. </p>


Sign in / Sign up

Export Citation Format

Share Document