scholarly journals Arthroscopic ACL reconstruction using fixed suspensory device versus adjustable suspensory device for femoral side graft fixation: What are the outcomes?

2019 ◽  
Vol 10 (1) ◽  
pp. 138-142 ◽  
Author(s):  
Hardik Sheth ◽  
Abhijeet Ashok Salunke ◽  
Raghav Barve ◽  
Rajat Nirkhe
2021 ◽  
Vol 33 (1) ◽  
Author(s):  
Naiyer Asif ◽  
Mohammad Jesan Khan ◽  
K. P. Haris ◽  
Shah Waliullah ◽  
Anubhav Sharma ◽  
...  

Abstract Purpose Suspensory devices are extensively used in the management of anterior cruciate ligament (ACL) tear. They include fixed- and adjustable-loop devices. There are only a few studies comparing the efficacy of these two devices in the available literature. Therefore, the aim of this study is to compare clinical outcomes between the adjustable-loop device (group I) and fixed-loop device (group II). Materials and methods This was a prospective randomized study. Both groups were equivalent in demographic, preoperative, and intraoperative variables. Twenty-three patients underwent femoral side graft fixation with adjustable-loop and 20 with fixed-loop devices. Four patients were lost to follow-up. Assessment of clinical outcome was done with International Knee Documentation Committee (IKDC) score, Lysholm score, and knee stability tests (Lachman test and pivot shift test). Patient evaluation was performed preoperatively and finally postoperatively 2 years after surgery. Results Postoperative IKDC scores of group I and II were 91.9 ± 3.6 and 91.5 ± 3.6, respectively, and Lysholm scores were 91.0 ± 3.6 and 91.4 ± 3.5, respectively, after 2 years; however, the difference in the outcomes was statistically insignificant (p > 0.05). Twenty patients (87%) in group I and 17 patients (85%) in group II had a negative Lachman test (p = 0.8). Twenty-two patients (95.7%) in group I and 19 patients (95%) in group II had a negative pivot shift test (p = 0.9). Conclusion ACL reconstruction with fixed- and adjustable-loop suspensory devices for graft fixation gives equivalent and satisfactory clinical results. Level of evidence 1.


2021 ◽  
Vol 9 (1) ◽  
pp. 232596712097434
Author(s):  
Daniel F. O’Brien ◽  
Lilah Fones ◽  
Victoria Stoj ◽  
Cory Edgar ◽  
Katherine Coyner ◽  
...  

Background: Suspensory fixation of anterior cruciate ligament (ACL) reconstruction (ACLR) grafts has emerged as a popular device for femoral graft fixation. However, improper deployment of the suspensory fixation can compromise proper graft tensioning, leading to failure and revision. Also, soft tissue interposition between the button and bone has been associated with graft migration and pain, occasionally requiring revision surgery. Many surgeons rely on manual testing and application of distal tension to the graft to confirm proper button deployment on the lateral cortex of the femur for ACL graft fixation. Purpose: To determine the reliability of the manual resistance maneuver when applying distal tension to deploy the suspensory device along the lateral cortex of the femur. Study Design: Case series; Level of evidence, 4. Methods: All patients undergoing ACLR with a suture button suspensory device for femoral fixation were eligible for enrollment in the study. The surgeries were performed by 3 board-certified, sports medicine fellowship–trained orthopaedic surgeons at a single outpatient surgical center between May 2018 and June 2019. All grafts were passed in a retrograde manner into the femoral tunnel, and a vigorous manual tensioning maneuver in a distal direction was placed on the graft to deploy and secure along the lateral cortex of the femur. Intraoperative mini c-arm fluoroscopy was obtained to demonstrate proper suture button positioning. If interposing tissue or an improperly flipped button was identified, rectifying steps were undertaken and recorded. Results: A total of 51 patients with a mean age of 33.3 years were included in the study. Of these patients, 74.5% had normal suture button positioning identified via intraoperative fluoroscopic imaging, while 15.7% had interposed soft tissue and 9.8% had an improperly flipped button. In all cases, the surgeon was able to rectify the malpositioning intraoperatively. Conclusion: Despite the manual sensation of proper suspensory button positioning, intraoperative fluoroscopy identified suture button deployment errors in ACLR 25% of the time. Correcting the malpositioning is not technically demanding. These findings advocate for routine intraoperative surveillance to confirm appropriate suture button seating during ACLR.


Author(s):  
Manoj R. Kashid ◽  
Rahool S. ◽  
Amit Chaudhry ◽  
Rajshekhar . ◽  
Varunendra Bahadur Singh ◽  
...  

<p class="abstract"><strong>Background:</strong> Arthroscopically aided anterior cruciate ligament reconstruction using hamstring graft can be fixed to femoral condyle by suspensory and aperture fixation methods. The following study was undertaken to investigate whether there is any difference in functional outcomes with these fixation methods as measured by the Lysholm knee score and to determine tunnel widening post operatively with these two methods and does it affect the functional outcome.</p><p class="abstract"><strong>Methods:</strong> 50 patients of clinically and radiologic ally diagnosed ACL tear fulfilling the inclusion and exclusion criteria were randomized into two groups to undergo arthroscopic ACL reconstruction using quadrupled hamstring graft with  suspensory (n=25) and aperture (n=25) fixation methods on femoral side. They were compared post operatively with Lysholm score, clinical laxity tests and percentage of tunnel enlargement using computed tomograms at 01 year.<strong></strong></p><p class="abstract"><strong>Results:</strong> At the end of 6 months there was no much difference in Lysholm score between both the groups (P =0.663) and at the end of 01 year aperture group had slightly better outcome. However, the difference was not statistically significant (p =0.173). There was more tunnel widening in the suspensory group especially of the femoral tunnel in the coronal plane. However, the amount of tunnel widening in both the groups was not significant statistically (P =0.071 and P =0.963). Tunnel widening is not associated with inferior clinical outcomes or functional knee score.</p><p><strong>Conclusions:</strong> Aperture and Suspensory fixation methods of hamstring graft at femoral condyle in ACL reconstruction are comparable clinically and there is no advantage of one particular method over other. Although comparatively more tunnel widening is seen in suspensory fixation methods; it does not affect the final clinical outcomes or functional knee scores. </p>


2021 ◽  
Author(s):  
Lifeng Yin ◽  
Hua Zhang ◽  
Junbo Liu ◽  
xingyu zhang ◽  
zhengxing wen ◽  
...  

Abstract Background: Cortical suspensory femoral fixation is commonly performed for graft fixation of the femur in anterior cruciate ligament (ACL) reconstruction using hamstring tendons. This study aimed to compare the morphology of femoral tunnel and graft insertion between fixed-length loop devices (FLD) and adjustable-length loop devices (ALD) using computed tomography (CT) images on the first day after hamstring ACL reconstruction. Methods: Overall, 94 patients who underwent ACL reconstruction from January 2016 to January 2021 were included. For femoral graft fixation, FLD (Smith & Nephew, ENDOBUTTON) and ALD (DePuy Synthes, Mitek sports medicine, RIGIDLOOP Adjustable cortical system) were used in 56 and 38 patients, respectively (FLD and ALD groups). For evaluation of the morphology of the humeral tunnel and graft depth, CT scans were performed immediately on the first postoperative day. The gap distance between the top of the graft and the socket tunnel end, the length of lateral bone preservation, and the depth of graft insertion were measured on the CT images. Results: The gap distance and bone preservation significantly differed between the two groups (1.90±1.81 mm and 14.35±4.67 mm in ALD groups; 7.08±2.63 mm and 7.35±3.62 mm in FLD groups, respectively; both P values < 0.01). The graft insertion depth did not significantly differ between the groups. Conclusion: The ALD group had a smaller gap distance, better bone preservation, and a similar graft insertion length in the femoral tunnel when compared to the FLD group. Based on these findings, ALD might be better for bone preservation and tunnel utilization in patients with short femoral tunnels. Trial registration: retrospectively registered


2017 ◽  
Vol 25 (1) ◽  
pp. 230949901769098
Author(s):  
Evan B Gaines ◽  
Diana Lau ◽  
Qais Naziri ◽  
Westley Hayes ◽  
Julio J. Jauregui ◽  
...  

Introduction: The incidence of graft length mismatch (GLM) during anterior cruciate ligament (ACL) reconstruction is reported to be up to 13%, with a rate of 20% when using bone-patellar tendon-bone (BPTB) allografts. Multiple techniques have been described to accommodate for the longer BPTB graft. As no study has compared the biomechanical properties of these methods (with cyclic loading), we evaluated the strength of four different surgical techniques used to accommodate for GLM during ACL reconstruction. Methods: A total of 32 fresh-frozen bovine tibiae and patellar tendons were divided into four groups based on the method of tibial graft fixation: (1) sutures tied over a post, (2) bone staples, (3) screws and washers, and (4) soft-tissue conversion with interference screw. Biomechanical testing was performed comparing the tensile properties of graft fixation techniques under cyclic loading. Ability to withstand 1500 cycles of load, the maximum tensile strength at load-to-failure, and the mode-of-failure were evaluated. Results: Only group 4 had all grafts intact after 1500 loading cycles, while the other groups had one graft failure at 338 (group 1), 240 (group 2), and 309 (group 3) cycles. The highest mean load-to-failure was observed in group 3 at 762 ± 173 N, which was found to be significantly higher than the other groups. The mean loads to failure in groups 1–4 were 453 ± 86 N, 485 ± 246 N, 762 ± 173 N, and 458 ± 128 N. Conclusion: While there are multiple viable techniques for fixation of a BPTB graft in the case of GLM, this study demonstrated that direct screw fixation offers the strongest construct.


2020 ◽  
Vol 22 (3) ◽  
pp. 181-185
Author(s):  
Ramy Said Assaad Ahmed Mohamed ◽  
Mohamed Hossam El-Din El-Shafie ◽  
Mohamed Ahmed El-Sheikh

Background. Anterior cruciate ligament (ACL) reconstruction has remained the gold standard for ACL injuries, especially for young individuals and athletes exposed to high level sporting activities aiming to return to their preinjury level of activity. Cortical suspensory femoral fixation is commonly performed for graft fixation to the femur in anterior cruciate ligament reconstruction using hamstring tendons. The aim of this study was to compare the clinical results of using fixed and adjustable loop cortical suspension devices in arthroscopic ACL reconstruction using the Lysholm Knee Scoring Scale after 12 months postoperatively. Material and methods. This study included a total of sixty patients who underwent transportal arthroscopic ACL reconstruction using a hamstring tendon autograft from November 2016 to December 2017. For femoral graft fixation, a fixed-length loop device was used in 30 patients (fixed-loop group) and an adjustable-length loop device was used in 30 patients (adjustable-loop group) randomly.For tibial graft fixation, interference screw was used for all patients. Results. The present study shows that there was no statistically significant difference between the two groups regarding the Lysholm score with highly statistically significant difference between preoperative and postoperative Lysholm score in each group separately. Conclusion. Both fixed loop and adjustable loop devices in ACL reconstruction provided good clinical outcomes but without significant statistical difference between both groups from the clinical point of view postoperatively using the Lysholm score.


2013 ◽  
Vol 28 (2) ◽  
pp. 126-132 ◽  
Author(s):  
Max Ettinger ◽  
Max Petri ◽  
Sebastian Kwisda ◽  
Christian Krettek ◽  
Michael Jagodzinski