Ferrihydrite Reduces the Bioavailability of Copper and Cadmium and Phosphorus Release Risk in Hydroxyapatite Amended Soil

Author(s):  
Yuchao Fan ◽  
Qiugang Wu ◽  
Binglu Bao ◽  
Yong Cao ◽  
Shiwen Zhang ◽  
...  
2013 ◽  
Vol 2013 ◽  
pp. 1-8 ◽  
Author(s):  
Maria L. Silveira ◽  
George A. O'Connor

This study was designed to evaluate the effects of temperature on the potential leachable P pool and distribution of chemical P forms in a biosolids-amended soil. A P-deficient Spodosol was incubated with seven biosolids and inorganic P fertilizer at 20 and 32°C for 90 days. Amendments were applied to provide a total P concentration of 112 mg kg−1soil, which correspond to a field application of~224 kg P ha−1. Cumulative P mass leached during the 90 d study for any P source was <2% of the applied P, but greater cumulative P mass was released from the biological P removal and composted biosolids than from the heat-dried materials. Increasing temperature (20 to 32°C) generally decreased cumulative P mass leached, suggesting greater soil affinity to retain P at 32°C than at 20°C. In a static incubation experiment (no leaching), soil water-extractable P concentrations were reduced over time, but no temperature effect was observed. Similarly, P distribution among the various fractions was not affected by temperature. The relatively great ability of the soil to sorb P masked differences in biosolids properties and the potential impacts of temperature on P lability. Additional work using low P-sorbing soils is warranted.


2019 ◽  
Vol 35 (2) ◽  
pp. 215-224
Author(s):  
Poonam Rani ◽  
◽  
Adarsh Kumar ◽  
Ramesh Chandra Arya ◽  
◽  
...  

2004 ◽  
Vol 33 (1) ◽  
pp. 99 ◽  
Author(s):  
Katarina Börling ◽  
Erasmus Otabbong ◽  
Elisabetta Barberis

1995 ◽  
Vol 30 (2) ◽  
pp. 243-246 ◽  
Author(s):  
Heather Culbert ◽  
Robert France

Abstract In urban centres, leaves are customarily gathered and temporarily stored in large roadside piles prior to their transport to disposal sites. To simulate the release of total phosphorus to urban runoff, birch and trembling aspen leaves were leached with distilled water in laboratory flasks. There was no difference in rate of total phosphorus release between oven-dried and non-dried leaves. An empirical equation developed from these data and knowledge of the litterfall rates for southern Canada indicated that leaves yielded from 11 to 45 mg TP m−2 of forested watershed. This amount represents up to 5% of the total export of total phosphorus from urban catchments and has the potential to exacerbate eutrophication of municipal waters if leaf pickup is not promptly enforced.


1985 ◽  
Vol 17 (11-12) ◽  
pp. 297-298 ◽  
Author(s):  
Takao Murakami ◽  
Atsushi Miyairi ◽  
Kazuhiro Tanaka

In Japan various biological phosphorus removal processes have recently been researched by laboratory or pilot plant scale studies and most of them have shown good results. Based on these results, the Japan Sewage Works Agency has conducted a full scale study of the biological phosphorus removal process from June 1982 until February 1983, which was the first full scale operation of this process in Japan. The main purpose of the study was to evaluate phosphorus removal efficiency and also nitrogen removal efficiency of the process and in addition, to ascertain the important operating factors of the process. For the study a treatment train of a large scale sewage treatment plant was remodelled. The aeration tank of 3.825 m3 volume was divided into four equal cells. The whole train including return sludge line was operated entirely independently of the other trains. During the experiment the train was operated under two different modes, Mode 1 and Mode 2. In Mode 1, the train was operated as an A/O process, the first cell of the aeration tank being anaerobic and the other cells oxic. In Mode 2, the train was operated as a Modified Phoredox process. In this case, the first cell was anaerobic, but the second cell was anoxic and nitrified liquor was returned to it from the end of the oxic cells. Mode 1 and Mode 2 were further divided into many ‘runs' and the flow rate varied between 12,550 m3 d−1 and 25,270 m3 d−1 , corresponding to retention times of 7.3 hours and 3.6 hours, respectively. Throughout the experimental period the mean value of influent (primary effluent) total-P concentration was 3.38 mg 1−1 , and that of the final effluent was 0.47 mg 1−1 . A cumulated frequency curve of the data showed that about 93% of measured effluent total-P was below 1.0 mg l−1 . Therefore, it can be concluded that with these influent total-P levels, biological phosphorus removal processes can sufficiently satisfy the effluent standard of 1 mg 1−1 total-P. Even when the process was operated as a Modified Phoredox Process, no obstruction to phosphorus removal because of nitrification was observed and phosphorus removal remained good. However, since the sewage treatment plant treated influent from a combined sewerage system, phosphorus removal was sometimes affected by heavy rainfalls. In such cases phosphorus release in the anaerobic cell was insufficient because of increased influent NOx concentration and accordingly increased denitrification level in the anaerobic cell. Therefore, as a result, enhanced phosphorus uptake in the following cells could not be observed. Higher process stability can be expected if an effective countermeasure to high influent NOx concentration can be made. Influence of flow rate fluctuation on the process was also studied. The treatment train was operated for a week under a daily flow rate fluctuation pattern which ranged between 460 m3 hr−1 and 820 m3 hr−1 . Nevertheless, the effluent total-P concentration showed no increase and stayed constantly lower than 0.5 mg 1−1. The oxidation reduction potential (ORP) was an effective control index to evaluate the degree of phosphorus release in the anaerobic cell. Water temperature did not affect phosphorus release and uptake rates.


1992 ◽  
Vol 26 (3-4) ◽  
pp. 567-576 ◽  
Author(s):  
F. A. Ruiz-Treviño ◽  
S. González-Martínez ◽  
C. Doria-Serrano ◽  
M. Hernández-Esparza

This paper presents the kinetic analysis, using Generalized Power-Law equations to describe the results of an experimental investigation conducted on a batch submerged biofilm reactor for phosphorus removal under an anaerobic/aerobic cycle. The observed rates and amounts of phosphorus release and organic substrate uptake in the anaerobic phase leads to a kinetic model in which these two variables are dependent on each other with a non-linear behaviour and reach equilibrium values in both cases, at different times and are function of rate constants ratio. The model has a good fit with experimental data except for C uptake at anaerobic contact times longer than four hours, where other kinetics are implied. Kinetic parameters were obtained with different initial substrate concentrations, anaerobic contact cycles, and type of substrates.


1995 ◽  
Vol 31 (5-6) ◽  
pp. 311-315 ◽  
Author(s):  
Timothy M. Straub ◽  
Ian L. Pepper ◽  
Charles P. Gerba

Current methods for the detection of enteric viruses in soil involve elution of viruses from soil colloids using beef extract or other proteins. These eluates are then assayed in cell culture and observed daily for cytopathic effects (CPE). While this method is suitable for detection of enteric viruses by cell culture, these eluates contain humic acids and heavy metals that interfere with polymerase chain reaction (PCR) detection. Using beef extract eluates prepared from sludge amended soil, 10 different methods of eluate purification were evaluated for their ability to remove PCR inhibition and maximize sensitivity. The treatment method providing the greatest sensitivity of poliovirus detection by PCR was the combination of Sephadex G-50 and Chelex-100. Using this method 2 plaque forming units (PFU) could be detected after reverse transcription and 30 cycles of PCR. Thirty (30) cycles of seminested PCR were performed on these samples to verify nucleic acid sequences and increase sensitivity after the first 30 cycles of PCR. Using seminested PCR, sensitivity of detection using the Sephadex G-50 and Chelex-100 treatment method to 0.2 PFU. In addition to providing excellent sensitivity for viruses in sludge amended soils, this treatment method is relatively simple compared to other methods.


Sign in / Sign up

Export Citation Format

Share Document