Electrochemical immunosensor based on metal ions functionalized CNSs@Au NPs nanocomposites as signal amplifier for simultaneous detection of triple tumor markers

2021 ◽  
Vol 880 ◽  
pp. 114882
Author(s):  
Lihua Li ◽  
Yan Wei ◽  
Shengpeng Zhang ◽  
Xishan Chen ◽  
Taili Shao ◽  
...  
The Analyst ◽  
2012 ◽  
Vol 137 (2) ◽  
pp. 393-399 ◽  
Author(s):  
Honglan Qi ◽  
Chen Ling ◽  
Qingyun Ma ◽  
Qiang Gao ◽  
Chengxiao Zhang

2008 ◽  
Vol 54 (9) ◽  
pp. 1481-1488 ◽  
Author(s):  
Jie Wu ◽  
Feng Yan ◽  
Xiaoqing Zhang ◽  
Yuetian Yan ◽  
Jinhai Tang ◽  
...  

Abstract Background: A reagentless sensor array for simultaneous multianalyte testing (SMAT) may enable accurate diagnosis and be applicable for point-of-care testing. We developed a disposable reagentless immunosensor array for simple immunoassay of panels of tumor markers. Methods: We carried out SMAT with a direct capture format, in which colloidal gold nanoparticles with bound horseradish peroxidase (HRP)-labeled antibodies were immobilized on screen-printed carbon electrodes with biopolymer/sol-gel to trap their corresponding antigens from sample solution. Upon formation of immunocomplex, the direct electrochemical signal of the HRP decreased owing to increasing spatial blocking, and the analytes could be simultaneously determined by monitoring the signal changes. Results: The proposed reagentless immunosensor array allowed simultaneous detection of carcinoma antigen 153, carcinoma antigen 125, carbohydrate antigen 199, and carcinoembryonic antigen in clinical serum samples in the ranges of 0.4–140 kU/L, 0.5–330 kU/L, 0.8–190 kU/L, and 0.1–44 μg/L, respectively, with detection limits of 0.2 kU/L, 0.5 kU/L, 0.3 kU/L, and 0.1 μg/L corresponding to the signals 3 SD above the mean of a zero standard. The interassay imprecision of the arrays was <9.5%, and they were stable for 35 days. The positivity detection rate of panels of tumor markers was >95.5% for 95 cases of cancer-positive sera. Conclusions: The immunosensor array provides a SMAT with short analytical time, small sampling volume, no need for substrate, and, no between-electrode cross-talk. This method not only proved the capability of the array in point-of-care testing, but also allowed simultaneous testing of several tumor markers.


2021 ◽  
Vol 56 (13) ◽  
pp. 8172-8185
Author(s):  
Manh B. Nguyen ◽  
Dau Thi Ngoc Nga ◽  
Vu Thi Thu ◽  
Benoît Piro ◽  
Thuan Nguyen Pham Truong ◽  
...  

Author(s):  
Yuqi Zhang ◽  
Wang Wang ◽  
Ran Li ◽  
Ensheng Zhang ◽  
Zhonghua Li ◽  
...  

RSC Advances ◽  
2014 ◽  
Vol 4 (43) ◽  
pp. 22463-22469 ◽  
Author(s):  
Hyun Kim ◽  
Yu Jeong Na ◽  
Eun Joo Song ◽  
Kyung Beom Kim ◽  
Jeong Mi Bae ◽  
...  

The receptor 1 provides a novel approach for the simultaneous colorimetric recognition of two metal ions Fe2+ and Cu2+.


Sign in / Sign up

Export Citation Format

Share Document