sampling volume
Recently Published Documents


TOTAL DOCUMENTS

139
(FIVE YEARS 35)

H-INDEX

24
(FIVE YEARS 5)

Sensors ◽  
2022 ◽  
Vol 22 (2) ◽  
pp. 556
Author(s):  
Wei Duan ◽  
Fuwu Yan ◽  
Yu Wang ◽  
Hui Zhang ◽  
Liuhao Ma ◽  
...  

A compact, sensitive laser-based absorption sensor for multispecies monitoring of methane (CH4), acetylene (C2H2) and ammonia (NH3) was developed using a compact multipass gas cell. The gas cell is 8.8 cm long and has an effective optical path length of 3.0 m with a sampling volume of 75 mL. The sensor is composed of three fiber-coupled distributed feedback lasers operating near 1512 nm, 1532 nm and 1654 nm, an InGaAs photodetector and a custom-designed software for data acquisition, signal processing and display. The lasers were scanned over the target absorption features at 1 Hz. First-harmonic-normalized wavelength modulation spectroscopy (f = 3 kHz) with the second harmonic detection (WMS-2f/1f) is employed to eliminate the unwanted power fluctuations of the transmitted laser caused by aerosol/particles scattering, absorption and beam-steering. The multispecies sensor has excellent linear responses (R2 > 0.997) within the gas concentration range of 1–1000 ppm and shows a detection limit of 0.32 ppm for CH4, 0.16 ppm for C2H2 and 0.23 ppm for NH3 at 1 s response time. The Allan–Werle deviation analysis verifies the long-term stability of the sensor, indicating a minimal detection limit of 20–34 ppb were achieved after 60–148 s integration time. Flow test of the portable multispecies sensor is also demonstrated in this work.


Animals ◽  
2021 ◽  
Vol 12 (1) ◽  
pp. 26
Author(s):  
Ali Hardan ◽  
Philip C. Garnsworthy ◽  
Matt J. Bell

The aim of this study was to investigate the use of signal processing to detect eructation peaks in CH4 released by cows during robotic milking, and to compare recordings from three gas analysers (Guardian SP and NG, and IRMAX) differing in volume of air sampled and response time. To allow comparison of gas analysers using the signal processing approach, CH4 in air (parts per million) was measured by each analyser at the same time and continuously every second from the feed bin of a robotic milking station. Peak analysis software was used to extract maximum CH4 amplitude (ppm) from the concentration signal during each milking. A total of 5512 CH4 spot measurements were recorded from 65 cows during three consecutive sampling periods. Data were analysed with a linear mixed model including analyser × period, parity, and days in milk as fixed effects, and cow ID as a random effect. In period one, air sampling volume and recorded CH4 concentration were the same for all analysers. In periods two and three, air sampling volume was increased for IRMAX, resulting in higher CH4 concentrations recorded by IRMAX and lower concentrations recorded by Guardian SP (p < 0.001), particularly in period three, but no change in average concentrations measured by Guardian NG across periods. Measurements by Guardian SP and IRMAX had the highest correlation; Guardian SP and NG produced similar repeatability and detected more variation among cows compared with IRMAX. The findings show that signal processing can provide a reliable and accurate means to detect CH4 eructations from animals when using different gas analysers.


2021 ◽  
Vol 2021 ◽  
pp. 1-9
Author(s):  
Xing-Tao Lin ◽  
Ge Sun ◽  
Jing-Qiang Zhao ◽  
Ling-Li Tang ◽  
Sheng-Hua Li ◽  
...  

In this study, UiO-66 was selected as sorbent media packed in the tube to selectively enrich trace levels of benzene homologues such as benzene, toluene, and xylene (BTX) in ambient air prior to thermal desorption (TD)-GC-MS determination. A series of experiments were conducted to obtain the optimal TD conditions. The results indicated that the optimal TD parameters were as follows: desorption temperature of 180°C, desorption flow rate of 50 mL min−1, and desorption time of 30 min. Furthermore, the method based on UiO-66 enrichment integrated with TD-GC-MS for trace levels of BTX was successfully developed. It exhibited a good linearity (R2 > 0.99) in the range of 50–1000 ng, except for p, m-xylene in the range of 100–2000 ng, and achieved the recovery of 69.4–101.3%, and the relative standard deviation of 3.8–6.4%. The detection limits of BTX were 1.6–4.0 ng; according to 10 L of sampling volume, the method detection limits would be in the range of 0.16–0.40 µg m−3. Additionally, the method was successfully applied to determine BTX in indoor air and showed good selectivity and sensitivity. In summary, the findings in this work revealed that UiO-66 was an attractive adsorbent for selective enrichment trace levels of BTX compounds in ambient air, which was favorable for the subsequent detection by TD-GC-MS.


Molecules ◽  
2021 ◽  
Vol 26 (19) ◽  
pp. 5725
Author(s):  
Yong-Hyun Kim ◽  
Mi-Kyung Song ◽  
Kyuhong Lee

This study evaluates the behavioral characteristics of components (methylisothiazolinone (MIT) and chloromethylisothiazolinone (CMIT)) contained in disinfectant solutions when they convert to liquid aerosols. The analytical method for MIT and CMIT quantitation was established and optimized using sorbent tube/thermal desorber-gas chromatography-mass spectrometry system; their behavioral characteristics are discussed using the quantitative results of these aerosols under different liquid aerosol generation conditions. MIT and CMIT showed different behavioral characteristics depending on the aerosol mass concentration and sampling time (sampling volume). When the disinfectant solution was initially aerosolized, MIT and CMIT were primarily collected on glass filter (MIT = 91.8 ± 10.6% and CMIT = 90.6 ± 5.18%), although when the generation and filter sampling volumes of the aerosols increased to 30 L, the relative proportions collected on the filter decreased (MIT = 79.0 ± 12.0% and CMIT = 39.7 ± 8.35%). Although MIT and CMIT had relatively high vapor pressure, in liquid aerosolized state, they primarily accumulated on the filter and exhibited particulate behavior. Their relative proportions in the aerosol were different from those in disinfectant solution. In the aerosol with mass concentration of ≤5 mg m−3, the relative proportion deviations of MIT and CMIT were large; when the mass concentration of the aerosol increased, their relative proportions constantly converged at a lower level than those in the disinfectant solution. Hence, it can be concluded that the behavioral characteristics and relative proportions need to be considered to perform the quantitative analysis of the liquid aerosols and evaluate various toxic effects using the quantitative data.


2021 ◽  
Vol 12 (1) ◽  
Author(s):  
Jan N. Hansen ◽  
An Gong ◽  
Dagmar Wachten ◽  
René Pascal ◽  
Alex Turpin ◽  
...  

AbstractMany biological processes happen on a nano- to millimeter scale and within milliseconds. Established methods such as confocal microscopy are suitable for precise 3D recordings but lack the temporal or spatial resolution to resolve fast 3D processes and require labeled samples. Multifocal imaging (MFI) allows high-speed 3D imaging but is limited by the compromise between high spatial resolution and large field-of-view (FOV), and the requirement for bright fluorescent labels. Here, we provide an open-source 3D reconstruction algorithm for multi-focal images that allows using MFI for fast, precise, label-free tracking spherical and filamentous structures in a large FOV and across a high depth. We characterize fluid flow and flagellar beating of human and sea urchin sperm with a z-precision of 0.15 µm, in a volume of 240 × 260 × 21 µm, and at high speed (500 Hz). The sampling volume allowed to follow sperm trajectories while simultaneously recording their flagellar beat. Our MFI concept is cost-effective, can be easily implemented, and does not rely on object labeling, which renders it broadly applicable.


Animals ◽  
2021 ◽  
Vol 11 (3) ◽  
pp. 714
Author(s):  
Domenico Ventrella ◽  
Nurit Ashkenazi ◽  
Alberto Elmi ◽  
Karel Allegaert ◽  
Camilla Aniballi ◽  
...  

The present review aims to summarize the main features of mammary gland anatomy, and the physiology of lactation and colostrum/milk in the most commonly used animal species for regulatory toxicity. The final goal is the selection of a preferred animal species to be enrolled in studies investigating the potential transfer of drugs and exogenous molecules through milk, within the Innovative Medicines Initiative (IMI) funded project ConcePTION. Reference data regarding humans were also collected and analyzed in order to highlight critical similarities and differences with the studied species. Additional practical considerations were also taken into account, such as ethical consideration regarding the chosen species which affects the group size, financial implications and technical feasibility of lactation trials (e.g., ease of sampling, volume of sampling, husbandry requirements and scientific recognition). In conclusion, the present analysis of the literature confirms the complexity of the decisional process behind the choice of an animal model for in vivo trials. For some of the evaluated species, data were either poor or missing, highlighting the necessity to generate more physiological background studies for species that are routinely used in laboratory settings. Overall, when taking into consideration ethical factors, feasible group size, milk volume and ease of milk collection, and physiological similarities with humans, minipigs seem to represent the most appropriate choice.


2021 ◽  
Vol 51 (3) ◽  
Author(s):  
Mehmet Reşit Sevinç

ABSTRACT: Şanlıurfa is the province with the third-largest agricultural area in Turkey. However, it has only 0.62% of the total number of cooperatives in the country. This study aimed to determine the perceptionsof farmers in Şanlıurfa regarding agricultural cooperatives and the factors affecting them. The main research material was obtained through face-to-face surveys involving farmers in Şanlıurfa selected by a simple random sampling method. The sampling volume was determined with a 95% confidence limit and a 5% error margin. Multiple regression analysis was used in Stata software. According to the results of the research, 39.7% of the participants were cooperative members and more than half of them were not active members. Of the participants, 30.3% had a positive perception of cooperatives, 36.82% were undecided, and 32.88% had negative opinions. Age, marital status, non-agricultural income, experience, social security, farmer registration system, cooperative membership, and land variables positively affected farmers’ perceptions. However, the variables of education, income, and union membership had negative effects on farmers’ perceptions. No statistically significant relationship was reported between a farmer’s perception and any of the following variables: the number of people that make up the farmer’s household, the number of individuals engaged in agriculture and non-agricultural work in the family, and the status of the farmer’s lease. Conceptual, local, cultural, educational, and structural problems related to cooperatives exist in Şanlıurfa.These issues need to be given more attention by the public. This research is the first study on this subject to be conducted in Şanlıurfa.


Author(s):  
Yuening Li ◽  
Frank Wania

The uncertainty of the partition coefficients between sorbent and gas phase propagates to sampling rate, effective sampling volume and ultimately to the air concentrations derived from a passive sampler operating in the curvi-linear uptake regime.


Author(s):  
Mohammad Kazemi ◽  
Babak Khorsandi ◽  
Laurent Mydlarski

AbstractThe relatively large sampling volume of acoustic Doppler velocimeters (ADVs) is expected to influence their measurement of turbulence. To study this effect, a series of experiments using different sampling volume sizes was conducted in an axisymmetric turbulent jet. The results show that the mean velocities are not significantly affected by the size of the sampling volume. On the other hand, reducing the sampling volume size results in an increase in the variances of the u and v velocities, while its effect on the variance of the w-velocity is negligible. Application of a noise reduction method to the data renders the velocity variances nearly independent of sampling volume size, suggesting that the difference was mainly due to Doppler noise. The principal conclusion of this work is therefore that – as long as the characteristic length of sampling volume is much smaller than the integral length scale of flow – increasing the sampling volume size (i.e., increasing spatial averaging over highly correlated scatterers) can reduce Doppler noise and result in more accurate measurements of the velocity variances. Application of noise reduction methods to the data is found to be especially important when the sampling volume size is reduced to capture smaller scales, or for near-boundary measurements. Furthermore, noise due to mean velocity shear, even at the largest velocity gradient along the jet radial profile, is found to be negligible in the present work.


Molecules ◽  
2020 ◽  
Vol 25 (24) ◽  
pp. 5788
Author(s):  
Qiong Jiang ◽  
Peng Xu ◽  
Juanjuan Feng ◽  
Min Sun

To establish an online analytical method towards estrogenic pollutants, a covalent organic porous polymer (COP) was in-situ synthesized on the surface of basalt fibers (BFs) for in-tube solid-phase microextraction (IT-SPME). The extraction tube, obtained via placing the modified BFs into a polyetheretherketone tube, was combined with high-performance liquid chromatography (HPLC) to achieve online IT-SPME-HPLC analysis. The important parameters, including sampling volume, sampling rate, organic solvent content and desorption time, were carefully investigated. Under the optimized conditions, the online analytical method was established for five estrogenic targets, with low limits of detection (0.001–0.005 μg/L), high enrichment factors (1800–2493), wide linear ranges (0.003–20, 0.015–20 μg/L) and satisfactory repeatability. It was successfully applied to detect five estrogens in a wastewater sample and a water sample in a polycarbonate cup. The BFs functionalized with COPs displayed excellent extraction effect for estrogenic pollutants, furthermore it has great potential in sample preparation or other fields.


Sign in / Sign up

Export Citation Format

Share Document