Evaluation of electro-oxidation of biologically treated landfill leachate using response surface methodology

2011 ◽  
Vol 188 (1-3) ◽  
pp. 261-268 ◽  
Author(s):  
Hui Zhang ◽  
Xiaoni Ran ◽  
Xiaogang Wu ◽  
Daobin Zhang
2019 ◽  
Vol 6 (1) ◽  
pp. 41-48 ◽  
Author(s):  
Abdul Aziz Hamidi ◽  
Syed Zainal Sharifah Farah Fariza ◽  
Alazaiza Motasem Y.D

Landfill leachate is highly polluted and generated as a result of water infiltration through solid waste produced domestically and industrially. This study investigated the applicability of the response surface methodology (RSM) to optimize the removal performances of chemical oxygen demand (COD), color, and suspended solids (SS) from landfill leachate by coagulation process using Tin tetrachloride pentahydrate. The leachate samples were collected from Alor Pongsu Landfill (APLS) in Perak, Malaysia. Before starting the experiments, general characterization was carried out for raw leachate samples to investigate their physical and chemical properties. The effects of the dosage and pH of SnCl4 on the removal performances were evaluated as well. An ideal experimental design was performed based on the central composite design (CCD) by RSM. In addition, this RSM was used to evaluate the effects of process variables and their interaction toward the attainment of their optimum conditions. The statistical design of the experiments and data analysis was resolved using the Design-Expert software. Further, the range of coagulant dosage and pH was selected based on a batch study which was conducted at 13000 mg/L to 17000 mg/L of SnCl4 and pH ranged from 6 to 10. The results showed that the optimum pH and dosage of SnCl4 were 7.17 and 15 g/L, respectively, where the maximum removal efficiency was 67.7% for COD and 100% for color and SS. The results were in agreement with the experimental data with a maximum removal efficiency of 67.84 %, 98.6 %, and 99.3%, for COD, color, and SS, respectively. Overall, this study verified that the RSM method was viable for optimizing the operational condition of the coagulation-flocculation process.


Processes ◽  
2020 ◽  
Vol 8 (5) ◽  
pp. 506
Author(s):  
Everton Gripa ◽  
Alyne M. Costa ◽  
Juacyara C. Campos ◽  
Fabiana V. da Fonseca

Batch ozonation was performed to assess its efficacy as a pretreatment for reverse osmosis (RO) membranes for treating leachate with high concentrations of recalcitrant organic compounds. Leachate samples from two different landfills were collected and characterized. The modified fouling index (MFI) was used to estimate the fouling potential of raw and ozonized leachates. A response surface experimental design was applied to optimize operational pH and ozone dose. The results demonstrate that the best operational conditions are 1.5 g/L of O3 at pH 12.0 and 1.5 g/L of O3 at pH 9.0 for Landfills 1 and 2, which reduce MFI by 96.22% and 94.08%, respectively. Additionally, they show toxicity factor decays of 98.44% for Landfill 1 and 93.75% for Landfill 2. These results, along with the similar behavior shown by leachate samples from distinct landfills, suggest that ozonation is a promising technology to fit this kind of wastewater into the requirements of RO membranes, enabling their use in such treatment.


2014 ◽  
Vol 22 (8) ◽  
pp. 5831-5841 ◽  
Author(s):  
Jefferson E. Silveira ◽  
Juan A. Zazo ◽  
Gema Pliego ◽  
Edério D. Bidóia ◽  
Peterson B. Moraes

2017 ◽  
Vol 35 (6) ◽  
pp. 636-646 ◽  
Author(s):  
Paria Amirian ◽  
Edris Bazrafshan ◽  
Abolfazl Payandeh

Leachate is the liquid formed when waste breaks down in the landfill and water filters through that waste. This liquid is very toxic and can pollute the land, ground water, and water resources. In most countries, it is mandatory for landfills to be protected against leachate. In addition to all other harms to the environment, disposal of raw landfill leachate can be a major source of hazard to closed water bodies. Hence, treatment of landfill leachate is considered an essential step prior to its discharge from source. This article describes the sonocatalytic degradation of chemical oxygen demand in landfill leachate using cupric oxide nanoparticles as sonocatalyst (cupric oxide/ultrasonic) and aims to establish this method as an effective alternative to currently used approaches. An ideal experimental design was carried out based on a central composite design with response surface methodology. The response surface methodology was used to evaluate the effect of process variables including pH values (3, 7, 11), cupric oxide nanoparticles dose (0.02, 0.035, 0.05 g), reaction time (10, 35, 60 minutes), ultrasonic frequency (35, 37, 130 KHz), and their interaction towards the attainment of their optimum conditions. The derived second-order model, including both significant linear and quadratic terms, seemed to be adequate in predicting responses (R2 = 0.9684 and prediction R2 = 0.9581). The optimum conditions for the maximum chemical oxygen demand sonocatalytic degradation of 85.82% were found to be pH 6.9, cupric oxide nanoparticles dosage of 0.05 gr L−1, and the ultrasonic frequency of 130 kHz at a contact time of 10 min.


Sign in / Sign up

Export Citation Format

Share Document