Experimental study of double-panel confined masonry walls under lateral loading

2018 ◽  
Vol 20 ◽  
pp. 531-543 ◽  
Author(s):  
Choayb Belghiat ◽  
Ali Messabhia ◽  
Jean-Patrick Plassiard ◽  
Mohamed Guenfoud ◽  
Olivier Plé ◽  
...  
2021 ◽  
Vol 48 (1) ◽  
pp. 89-97
Author(s):  
Jorge Varela-Rivera ◽  
Joel Moreno-Herrera ◽  
Luis Fernandez-Baqueiro ◽  
Juan Cacep-Rodriguez ◽  
Cesar Freyre-Pinto

An experimental study on the out-of-plane behavior of confined masonry walls is presented. Four confined walls with aspect ratios greater than one were tested in the laboratory. Walls were subjected to combined axial and out-of-plane uniform loads. The variables studied were the aspect ratio and the axial compressive stress of walls. It was observed that the out-of-plane strength of walls increased as the aspect ratio or the axial compressive stress increased. Failure of walls was associated with crushing of masonry. Analytical out-of-plane strength of walls was determined using the yielding line, failure line, modified yielding line, compressive strut and bidirectional strut methods. It was concluded that the experimental out-of-plane strength of walls was best predicted with the bidirectional strut method.


2017 ◽  
Vol 747 ◽  
pp. 594-603 ◽  
Author(s):  
Hu Xu ◽  
Hao Wu ◽  
Cristina Gentilini ◽  
Qi Wang Su ◽  
Shi Chun Zhao

In this study, confined masonry specimens with regular arranged openings are tested in order to study the influence of different enhancements of the columns on seismic failure modes. In particular, five brick masonry walls and three half-scale two-storey masonry structures are tested under quasi-static loads. The experimental results show that increasing column ratio improves the seismic behavior of the wall specimens to some extent, but an excessive reinforcement ratio of the columns decreases the ductility. The global failure mode of the two-storey masonry structures is modified by inserting iron wires in the mortar bed joints, improving the structural collapse resistant capacity effectively.


2021 ◽  
pp. 875529302098801
Author(s):  
Xin Wang ◽  
Qun Xie ◽  
Zhenli Wu ◽  
Fanyang Bu ◽  
Fei Wang

An experimental study was conducted to investigate the seismic performance of masonry walls strengthened using hybrid fiber-reinforced reactive powder concrete (HyFRRPC) as a coating. The proposed reinforcement technique was employed to improve the overall strength and structural integrity of the confined masonry wall. In order to guarantee the composite action between the masonry substrate and the coating material, material tests were conducted to achieve an optimal mixture for the HyFRRPC. Then, six full-scaled confined masonry specimens strengthened by HyFRRPCs with varied strengthening configurations were tested under in-plane quasi-static horizontal loading. The test and analysis results indicated that the proposed HyFRRPC-strengthening technique can effectively improve the lateral carrying capacity, displacement ductility, and energy dissipation capacity of masonry walls, and provide an optimal reinforcement. Finally, a simplified analytical model was also proposed for practical application.


2008 ◽  
Vol 64 (4) ◽  
pp. 692-704 ◽  
Author(s):  
Abdelkrim BOURZAM ◽  
Tetsuro GOTO ◽  
Masakatsu MIYAJIMA

2016 ◽  
Vol 711 ◽  
pp. 982-988
Author(s):  
Alex Brodsky ◽  
David Z. Yankelevsky

Numerous studies have been conducted on the in plane behavior of masonry infill walls to lateral loading simulating earthquake action on buildings. The present study is focused on a problem that has almost not been studied regarding the vertical (opposed to lateral) in-plane action on these walls. This may be of concern when a supporting column of a multi-storey reinforced concrete frame with infill masonry walls undergoes a severe damage due to an extreme loading such as a strong earthquake, car impact or military or terror action in proximity to the column. The loss of the supporting column may cause a fully or partly progressive collapse to a bare reinforced concrete frame, without infill masonry walls. The presence of the infill masonry walls may restrain the process and prevent the development of a progressive collapse. The aim of the present study is to test the in-plane composite action of Reinforced Concrete (RC) frames with infill masonry walls under vertical loading through laboratory experiments and evaluate the contributions of infill masonry walls, in an attempt to examine the infill masonry wall added resistance to the bare frame under these circumstances. Preliminary results of laboratory tests that have been conducted on reinforced concrete infilled frames without a support at their end, under monotonic vertical loading along that column axis will be presented. The observed damages and failure modes under vertical loading are clearly different from the already known failure modes observed in the case of lateral loading.


2017 ◽  
Vol 20 (11) ◽  
pp. 1632-1643 ◽  
Author(s):  
Masoud Amouzadeh Tabrizi ◽  
Masoud Soltani

This article focuses on the experimental and analytical investigations of masonry walls surrounded by tie-elements under in-plane loads. The experimental results of an unconfined and a confined masonry wall, tested under reversed cyclic lateral loads, are presented. For numerical study, a micro-modeling strategy, using smeared-crack-based approach, is adopted. In order to validate the numerical approach, experimental test results and data obtained from the literature are used, and through a systematic parametric study, the influence of adjoining walls and number of tie-columns on the seismic behavior of confined masonry panels is numerically assessed and a simple but rational method for predicting the nonlinear behavior of these structures is proposed.


Sign in / Sign up

Export Citation Format

Share Document