Experimental thermal bowing response of precast concrete insulated wall panels with stiff shear connectors and simple supports

2020 ◽  
Vol 30 ◽  
pp. 101319
Author(s):  
Sergio Arevalo ◽  
Douglas Tomlinson
PCI Journal ◽  
1996 ◽  
Vol 41 (3) ◽  
pp. 64-80 ◽  
Author(s):  
Khaled A. Soudki ◽  
Jeffrey S. West ◽  
Sami H. Rizkalla ◽  
Bruce Blackett

2018 ◽  
Vol 22 (10) ◽  
pp. 3961-3971 ◽  
Author(s):  
Huanzhi Jiang ◽  
Zhengxing Guo ◽  
Jiabin Liu ◽  
Hui Liu

2013 ◽  
Vol 663 ◽  
pp. 154-158 ◽  
Author(s):  
Tae Sik Oh ◽  
Seok Joon Jang ◽  
Kang Min Lee ◽  
Hyun Do Yun

Precast concrete sandwich panels (PCSP) are often used as exterior cladding of residential buildings due to thermal efficiency. PCSP systems consist of two precast reinforced concrete walls separated by a layer of insulation and connected with connectors which penetrate the insulation layer and are anchored at two precast walls. This paper provides the pull-out test results of concrete sandwich panel (CSP) with non-shear connectors. The variables in this study were the casting direction of reinforced concrete walls and types of insulation. Test results indicated that the types of insulations and casting direction have a significant effect on the bond strength between concrete wall and insulation. The effect of insulation type is notable for CSP cast horizontally concrete walls.


2017 ◽  
Vol 138 ◽  
pp. 367-380 ◽  
Author(s):  
Matthew J. Gombeda ◽  
Patrick Trasborg ◽  
Clay J. Naito ◽  
Spencer E. Quiel

Sign in / Sign up

Export Citation Format

Share Document