Seismic performance enhancing of novel self-centering precast concrete frame using replaceable hysteretic dampers

2021 ◽  
pp. 103059
Author(s):  
Fangfang Geng ◽  
Youliang Ding ◽  
Honglei Wu ◽  
Jianping Yang ◽  
Wei Shen
2018 ◽  
Vol 8 (10) ◽  
pp. 1871 ◽  
Author(s):  
Xueyuan Yan ◽  
Suguo Wang ◽  
Canling Huang ◽  
Ai Qi ◽  
Chao Hong

Precast monolithic structures are increasingly applied in construction. Such a structure has a performance somewhere between that of a pure precast structure and that of a cast-in-place structure. A precast concrete frame structure is one of the most common prefabricated structural systems. The post-pouring joint is important for controlling the seismic performance of the entire precast monolithic frame structure. This paper investigated the joints of a precast prestressed concrete frame structure. A reversed cyclic loading test was carried out on two precast prestressed concrete beam–column joints that were fabricated with two different concrete strengths in the keyway area. This testing was also performed on a cast-in-place reinforced concrete joint for comparison. The phenomena such as joint crack development, yielding, and ultimate damage were observed, and the seismic performance of the proposed precast prestressed concrete joint was determined. The results showed that the precast prestressed concrete joint and the cast-in-place joint had a similar failure mode. The stiffness, bearing capacity, ductility, and energy dissipation were comparable. The hysteresis curves were full and showed that the joints had good energy dissipation. The presence of prestressing tendons limited the development of cracks in the precast beams. The concrete strength of the keyway area had little effect on the seismic performance of the precast prestressed concrete joints. The precast prestressed concrete joints had a seismic performance that was comparable to the equivalent monolithic system.


2021 ◽  
Vol 242 ◽  
pp. 112619
Author(s):  
Xiangmin Li ◽  
Shun Xiao ◽  
Rundong Gao ◽  
Kent A. Harries ◽  
Zhuolin Wang ◽  
...  

2020 ◽  
Vol 10 (18) ◽  
pp. 6510
Author(s):  
Fangfang Geng ◽  
Youliang Ding ◽  
Honglei Wu ◽  
Kang Yang

The damage to structures caused by the velocity pulse effect of near-fault earthquake waves cannot be ignored, yet there are few studies on the risk assessment of seismic performance for precast concrete frame under near-fault earthquake waves. A novel self-centering precast concrete (SCPC) frame with hysteretic dampers is proposed to obtain great self-recovering and energy consumption characteristics. To accurately assess the seismic behaviors of the novel SCPC frame under the near-fault earthquake waves, a prototype structure is modelled and elastoplastic dynamic analysis is conducted at the design basis earthquake (DBE) and the maximum considered earthquake (MCE) seismic levels. Incremental dynamic analysis and the vulnerability analysis are performed. Annual and 50-year exceeding probabilities of the novel SCPC frame are calculated afterwards. In addition, the reinforced concrete (RC)frame and the traditional SCPC frame are also modelled, whose section sizes, reinforcements arrangement and seismic intensity are consistent with the novel SCPC frame. The dynamic time-history analysis at the two seismic levels are also carried out for two types of frames. The analysis results demonstrate that the novel SCPC frame has great seismic performance and low seismic risk possibility under the near-fault earthquakes loading.


2018 ◽  
Vol 27 (18) ◽  
pp. e1544 ◽  
Author(s):  
Bo Feng ◽  
Feng Xiong ◽  
Jiang Chen ◽  
Wen Chen ◽  
Yiping Zhang

Author(s):  
Yadong Li ◽  
Fangfang Geng ◽  
Youliang Ding ◽  
Libin Wang

The self-centering precast concrete frame structure combines the advantages of industrialization and low earthquake damage, and its energy dissipation capacity and seismic performance have always been the focus of research. This paper proposed a kind of self-centering precast concrete frame with hysteretic dampers (SCPCHD). Its modular design makes the energy dissipation device and components easy to repair and replace. In order to obtain the optimal design, the finite element models of SCPCHD frames with different layout types of post-tensioned (PT) tendons and different shapes of hysteretic dampers are established, and the elastoplastic dynamic time-history analyses are carried out. The results show that the layout types and vertical margin of PT tendons have little effect on the displacement response of the frame structure. Compared to linear PT tendons, polygonal PT tendons can better bear the bending moment of the beam and reduce the stress of longitudinal reinforcements in the beam. The reduce effect of shortening the vertical margin on the tensile damage of beam concrete is obvious in the frame with polygonal PT tendons, but not obvious in the frame with linear PT tendons. Rational design of the prestressing force also plays a crucial role in the energy dissipation capacity of SCPCHD frames.


Sign in / Sign up

Export Citation Format

Share Document