scholarly journals Endodontic Microsurgery Using Dynamic Navigation System: A Case Report

2019 ◽  
Vol 45 (11) ◽  
pp. 1397-1402.e6 ◽  
Author(s):  
Gianluca Gambarini ◽  
Massimo Galli ◽  
Luigi V. Stefanelli ◽  
Dario Di Nardo ◽  
Antonio Morese ◽  
...  
Cureus ◽  
2020 ◽  
Author(s):  
Clara K Starkweather ◽  
Ramin A Morshed ◽  
Caleb Rutledge ◽  
Phiroz Tarapore

2007 ◽  
Vol 40 (4) ◽  
pp. S9
Author(s):  
Buelent Koektuerk ◽  
Jim Hansen ◽  
Thomas Zerm ◽  
Julian Chun ◽  
Feifan Ouyang ◽  
...  

2019 ◽  
Vol 3 (2) ◽  
pp. 196-198 ◽  
Author(s):  
Hideaki Kashiro ◽  
Keiji Wada ◽  
Mitsuru Yui ◽  
Ryo Tamaki ◽  
Daisuke Numaguchi ◽  
...  

2018 ◽  
Vol 29 ◽  
pp. 59-59
Author(s):  
Gerardo Pellegrino ◽  
Valerio Taraschi ◽  
Agnese Ferri ◽  
Andrea Zacchino ◽  
Claudio Marchetti

2021 ◽  
Vol 11 (22) ◽  
pp. 10756
Author(s):  
Tomoyuki Setoguchi ◽  
Yoichiro Ogino ◽  
Riichi Ouchida ◽  
Akira Takahashi ◽  
Yasunori Ayukawa ◽  
...  

The published article [...]


2020 ◽  
Vol 4 (4) ◽  
pp. 380-383
Author(s):  
Kenji Hagiwara ◽  
Keiji Wada ◽  
Ryo Tamaki ◽  
Tomohisa Inoue ◽  
Ken Okazaki

2021 ◽  
Vol 11 (14) ◽  
pp. 6593
Author(s):  
Tomoyuki Setoguchi ◽  
Yoichiro Ogino ◽  
Riichi Ouchida ◽  
Akira Takahashi ◽  
Yasunori Ayukawa ◽  
...  

The aim of this pilot study was to evaluate the accuracy of a newly developed dynamic navigation system and to compare the accuracy between flapless and open-flap surgery, and between surgeons. The subjects were patients who were scheduled to receive implants of the same size using the newly developed dynamic navigation system. The study’s procedures included cone beam computed tomography (CBCT) filming with fiducials, virtual planning of implant placement and the use of motion tracking technology for calibration and practical implant placement. The accuracy was evaluated using preoperative (virtual implant) and postoperative (actual implant) CBCT images based on angular, apical, coronal and vertical deviations. The differences of deviations between flapless and open-flap surgery, and between two surgeons, were statistically compared. In total, 66 implants were placed in 39 patients. The median and interquartile range of angular, apical, coronal and vertical deviations were 3.07° (2.52–3.54°), 0.96 mm (0.75–1.42 mm), 0.76 mm (0.57–1.37 mm) and 0.71 mm (0.61–0.88 mm), respectively. These deviations were similar to those found in previous studies. Flapless surgery resulted in a more accurate placement with respect to apical and coronal deviations, and the differences between the two surgeons were limited. The newly developed dynamic navigation system is considered to be eligible for clinical use.


Sign in / Sign up

Export Citation Format

Share Document