Total shoulder arthroplasty using the superior approach: Influence on glenoid loosening and superior migration in the long-term follow-up after Neer II prosthesis installation

2008 ◽  
Vol 17 (4) ◽  
pp. 554-563 ◽  
Author(s):  
Sébastien Zilber ◽  
Catherine Radier ◽  
Jean-Marie Postel ◽  
Stéphane Van Driessche ◽  
Jérome Allain ◽  
...  
2013 ◽  
Vol 22 (4) ◽  
pp. e31
Author(s):  
Edwin R. Cadet ◽  
Peter Kok ◽  
R. Michael Greiwe ◽  
Christopher S. Ahmad ◽  
William N. Levine ◽  
...  

2014 ◽  
Vol 23 (9) ◽  
pp. 1301-1308 ◽  
Author(s):  
Edwin R. Cadet ◽  
Peter Kok ◽  
Raymond M. Greiwe ◽  
Andrew Chan ◽  
Christopher S. Ahmad ◽  
...  

Author(s):  
Sascha Beck ◽  
Theodor Patsalis ◽  
André Busch ◽  
Florian Dittrich ◽  
Alexander Wegner ◽  
...  

Abstract Introduction Stemmed humeral implants have represented the gold standard in total shoulder arthroplasty (TSA) for decades. Like many other joints, the latest trends in TSA designs aim at bone preservation. Current studies have demonstrated that native proximal humeral bone stresses are most closely mimicked by stemless implants. Nevertheless, there are concerns about the long-term performance of stemless designs. The aim of the present study was to evaluate the long-term radiographic changes at the proximal humerus in anatomical stemless press-fit TSA. Materials and Methods Between 2008 and 2010, 48 shoulders in 43 patients were resurfaced using an anatomic stemless shoulder prosthesis (TESS, Biomet). Thirty shoulders in twenty-five patients who were aged 65.7 ± 9.9 (34 to 82) years were available for clinical and radiographic review at a mean follow-up of 94.0 ± 8.9 (78 to 110) months. Results Radiographic changes of the proximal humerus due to stress shielding were found in 38.4% of the stemless TESS implants. Mild stress shielding accounted for 80% of the observed radiographic changes. Radiographs exhibited stable fixation of the stemless humeral press-fit implant at early and late follow-up. In contrast, radiolucent lines at the glenoid implant were found in 96.1% of the cases. Irrespective of the degree of radiographic changes, clinical scores (VAS, Quick-DASH, Constant score) significantly improved at follow-up. Conclusions The anatomic stemless press-fit implant seems to be favorable in terms of implant-related stress shielding. Clinical outcome was not affected by radiographic changes, demonstrating an 8-year clinical performance that seems to be comparable to conventional stemmed TSA.


2022 ◽  
Vol 23 (1) ◽  
Author(s):  
Hyojune Kim ◽  
Chul-Ho Kim ◽  
Minsoo Kim ◽  
Wonsun Lee ◽  
In-Ho Jeon ◽  
...  

Abstract Purpose We aimed to compare the outcomes and complications of anatomical shoulder arthroplasty (aTSA) and reverse total shoulder arthroplasty (rTSA) for primary glenohumeral osteoarthritis with intact cuff tissue. Materials and methods The MEDLINE, Embase, and Cochrane Library databases were systematically searched for studies published before March 2, 2021 using the PRISMA guidelines. Studies were included if they directly compared aTSA and rTSA for treating primary glenohumeral arthritis. A meta-analysis was performed using six studies that compared radiologic outcomes, functional scores, and range of motion (ROM). All the data were pooled using a random-effects model. Odds ratios (ORs) and 95% confidence intervals (CIs) were calculated as dichotomous data, while continuous data were analyzed using mean differences with 95% CIs. Results Two independent researchers reviewed 1,061 studies. Six studies met the inclusion criteria. The range of motion, especially external rotation, was better for aTSA than for rTSA (MD = − 10.28, 95% CI: − 16.69 to − 3.88, P = 0.002). Functional scores showed no difference between aTSA and rTSA. Glenoid loosening (OR = 0.17, 95% CI: 0.06–0.50, P = 0.001) was more common with aTSA, and scapula notching (OR = 10.63, 95% CI: 1.73–65.27, P = 0.01) with rTSA. In the mid-term follow-up, the overall revision rate showed no difference between aTSA and rTSA, with a pooled OR of 0.33 (95% CI: 0.07–1.57, P = 0.16). Conclusion A better ROM was achieved after aTSA than after rTSA. There was no difference in the revision rate at mid-term follow-up between aTSA and rTSA. Glenoid loosening was more common with aTSA, and scapula notching with rTSA. Level of evidence: Level IV, Meta-analysis.


2018 ◽  
Vol 138 (12) ◽  
pp. 1647-1652 ◽  
Author(s):  
Stephan Uschok ◽  
Sebastian Herrmann ◽  
Stephan Pauly ◽  
Carsten Perka ◽  
Stefan Greiner

2018 ◽  
Vol 100-B (4) ◽  
pp. 485-492 ◽  
Author(s):  
M. O. Gauci ◽  
N. Bonnevialle ◽  
G. Moineau ◽  
M. Baba ◽  
G. Walch ◽  
...  

Aims Controversy about the use of an anatomical total shoulder arthroplasty (aTSA) in young arthritic patients relates to which is the ideal form of fixation for the glenoid component: cemented or cementless. This study aimed to evaluate implant survival of aTSA when used in patients aged < 60 years with primary glenohumeral osteoarthritis (OA), and to compare the survival of cemented all-polyethylene and cementless metal-backed glenoid components. Materials and Methods A total of 69 consecutive aTSAs were performed in 67 patients aged < 60 years with primary glenohumeral OA. Their mean age at the time of surgery was 54 years (35 to 60). Of these aTSAs, 46 were undertaken using a cemented polyethylene component and 23 were undertaken using a cementless metal-backed component. The age, gender, preoperative function, mobility, premorbid glenoid erosion, and length of follow-up were comparable in the two groups. The patients were reviewed clinically and radiographically at a mean of 10.3 years (5 to 12, sd 26) postoperatively. Kaplan–Meier survivorship analysis was performed with revision as the endpoint. Results A total of 26 shoulders (38%) underwent revision surgery: ten (22%) in the polyethylene group and 16 (70%) in the metal-backed group (p < 0.0001). At 12 years’ follow-up, the rate of implant survival was 74% (sd 0.09) for polyethylene components and 24% (sd 0.10) for metal-backed components (p < 0.0002). Glenoid loosening or failure was the indication for revision in the polyethylene group, whereas polyethylene wear with metal-on-metal contact, instability, and insufficiency of the rotator cuff were the indications for revision in the metal-backed group. Preoperative posterior subluxation of the humeral head with a biconcave/retroverted glenoid (Walch B2) had an adverse effect on the survival of a metal-backed component. Conclusion The survival of a cemented polyethylene glenoid component is three times higher than that of a cementless metal-backed glenoid component ten years after aTSA in patients aged < 60 years with primary glenohumeral OA. Patients with a biconcave (B2) glenoid have the highest risk of failure. Cite this article: Bone Joint J 2018;100-B:485–92.


2019 ◽  
Vol 12 (1_suppl) ◽  
pp. 31-39
Author(s):  
Mark Ross ◽  
Jean-Marc Glasson ◽  
Justin Alexander ◽  
Christopher G Conyard ◽  
Benjamin Hope ◽  
...  

Background Recessed mini-glenoid components provide an alternative to total shoulder replacement that may avoid some of the known shortcomings and complications associated with shoulder hemiarthroplasty or standard glenoid components in difficult cases. This study reports survivorship, radiological and clinical outcomes of a recessed mini-glenoid implant in a consecutive cohort. Methods Retrospective cohort study reporting outcomes of 28 consecutive shoulders (27 patients) following total shoulder replacement using a recessed, cemented mini-glenoid implant at two sites. Results The most frequent diagnosis was primary osteoarthritis (79%); glenoid morphology was Walch Type A (67%), B1 15%, B2 10% and C 10%. At final follow-up, pain was 16.3 (SD = 23.1), American Shoulder and Elbow Score was 64.5 (SD = 31.9) and (normalized) Constant score was 83.0 (SD = 20.7). Implant survivorship at average final follow-up of seven years (3–13) was 96.4%. Seven mini-glenoids showed small peripheral radiolucent lines at one-year X-ray follow-up but were non-progressive on subsequent imaging. Discussion Recessed polyethylene mini-glenoid is an attractive alternative for shoulder arthroplasty and provides an intermediate solution between standard glenoid components and hemiarthroplasty. Our medium to long-term results demonstrate reliable clinical outcomes, absence of glenoid erosion, low complication rate and satisfactory implant survivorship.