scholarly journals Anatomical total shoulder arthroplasty in young patients with osteoarthritis

2018 ◽  
Vol 100-B (4) ◽  
pp. 485-492 ◽  
Author(s):  
M. O. Gauci ◽  
N. Bonnevialle ◽  
G. Moineau ◽  
M. Baba ◽  
G. Walch ◽  
...  

Aims Controversy about the use of an anatomical total shoulder arthroplasty (aTSA) in young arthritic patients relates to which is the ideal form of fixation for the glenoid component: cemented or cementless. This study aimed to evaluate implant survival of aTSA when used in patients aged < 60 years with primary glenohumeral osteoarthritis (OA), and to compare the survival of cemented all-polyethylene and cementless metal-backed glenoid components. Materials and Methods A total of 69 consecutive aTSAs were performed in 67 patients aged < 60 years with primary glenohumeral OA. Their mean age at the time of surgery was 54 years (35 to 60). Of these aTSAs, 46 were undertaken using a cemented polyethylene component and 23 were undertaken using a cementless metal-backed component. The age, gender, preoperative function, mobility, premorbid glenoid erosion, and length of follow-up were comparable in the two groups. The patients were reviewed clinically and radiographically at a mean of 10.3 years (5 to 12, sd 26) postoperatively. Kaplan–Meier survivorship analysis was performed with revision as the endpoint. Results A total of 26 shoulders (38%) underwent revision surgery: ten (22%) in the polyethylene group and 16 (70%) in the metal-backed group (p < 0.0001). At 12 years’ follow-up, the rate of implant survival was 74% (sd 0.09) for polyethylene components and 24% (sd 0.10) for metal-backed components (p < 0.0002). Glenoid loosening or failure was the indication for revision in the polyethylene group, whereas polyethylene wear with metal-on-metal contact, instability, and insufficiency of the rotator cuff were the indications for revision in the metal-backed group. Preoperative posterior subluxation of the humeral head with a biconcave/retroverted glenoid (Walch B2) had an adverse effect on the survival of a metal-backed component. Conclusion The survival of a cemented polyethylene glenoid component is three times higher than that of a cementless metal-backed glenoid component ten years after aTSA in patients aged < 60 years with primary glenohumeral OA. Patients with a biconcave (B2) glenoid have the highest risk of failure. Cite this article: Bone Joint J 2018;100-B:485–92.

2021 ◽  
Vol 10 (14) ◽  
pp. 3081
Author(s):  
Anthony Hervé ◽  
Mickael Chelli ◽  
Pascal Boileau ◽  
Gilles Walch ◽  
Luc Favard ◽  
...  

Background: Total shoulder arthroplasty (TSA) and hemiarthroplasty (HA) have shown good clinical outcomes in primary avascular necrosis of the humeral head (PANHH) both in short and long terms. The purpose of this study was to assess the complications, the clinical and radiological outcomes of shoulder arthroplasty in young patients with PANHH. Methods: One hundred and twenty-seven patients aged under 60 years old and suffering from PANHH were operated with arthroplasty. Patients were assessed clinically and radiographically before surgery with a minimum of 2 years of follow up (FU). Results: HA was performed on 108 patients (85%). Two patients were revised for painful glenoid wear after 2 and 4 years. TSA was performed on 19 patients (15%). Five TSA had to be revised for glenoid loosening (n = 4) or instability (n = 1). Revision rate was 26% with TSA and 2% with HA. There were no significant differences between HA and TSA in terms of clinical outcomes. Conclusions: With a mean FU of 8 years, HA and TSA improved clinical outcomes of patients with PANHH. HA revisions for painful glenoid wear were rare (2%). The revision rate was excessively high with TSA (26%).


2020 ◽  
pp. 175857322090998
Author(s):  
Raymond E Chen ◽  
Alexander M Brown ◽  
Alexander S Greenstein ◽  
Sandeep Mannava ◽  
Ilya Voloshin

Background Total shoulder arthroplasty with second generation porous tantalum glenoid implants (Trabecular Metal™) has shown good short-term outcomes, but mid-term outcomes are unknown. This study describes the clinical, radiographic, and patient-rated mid-term outcomes of total shoulder arthroplasty utilizing cemented Trabecular Metal™ glenoid components. Methods Patients who underwent anatomic total shoulder arthroplasty with cemented Trabecular Metal™ glenoid components for primary osteoarthritis were identified for minimum five-year follow-up. The primary outcome measure was implant survival; secondary outcome measures included patient-rated outcome scores, shoulder range of motion findings, and radiographic analysis. Results Twenty-seven patients were enrolled in the study. Twenty-one patients had full radiographic follow-up. Mean follow-up was 6.6 years. There was 100% implant survival. Shoulder range of motion significantly improved and the mean American Shoulder and Elbow Society score was 89.8. There was presence of metal debris radiographically in 24% of patients. Twenty-nine percent of patients had evidence of radiolucency. Fourteen percent of patients had moderate superior subluxation. Conclusion Total shoulder arthroplasty with second generation cemented Trabecular Metal™ glenoid components yielded good outcomes at mean 6.6-year follow-up. Metal debris incidence and clinical outcomes were similar to short-term findings. The presence of metal debris did not significantly affect clinical outcomes. Continued observation of these patients will elucidate longer-term implant survival.


2022 ◽  
Vol 23 (1) ◽  
Author(s):  
Hyojune Kim ◽  
Chul-Ho Kim ◽  
Minsoo Kim ◽  
Wonsun Lee ◽  
In-Ho Jeon ◽  
...  

Abstract Purpose We aimed to compare the outcomes and complications of anatomical shoulder arthroplasty (aTSA) and reverse total shoulder arthroplasty (rTSA) for primary glenohumeral osteoarthritis with intact cuff tissue. Materials and methods The MEDLINE, Embase, and Cochrane Library databases were systematically searched for studies published before March 2, 2021 using the PRISMA guidelines. Studies were included if they directly compared aTSA and rTSA for treating primary glenohumeral arthritis. A meta-analysis was performed using six studies that compared radiologic outcomes, functional scores, and range of motion (ROM). All the data were pooled using a random-effects model. Odds ratios (ORs) and 95% confidence intervals (CIs) were calculated as dichotomous data, while continuous data were analyzed using mean differences with 95% CIs. Results Two independent researchers reviewed 1,061 studies. Six studies met the inclusion criteria. The range of motion, especially external rotation, was better for aTSA than for rTSA (MD = − 10.28, 95% CI: − 16.69 to − 3.88, P = 0.002). Functional scores showed no difference between aTSA and rTSA. Glenoid loosening (OR = 0.17, 95% CI: 0.06–0.50, P = 0.001) was more common with aTSA, and scapula notching (OR = 10.63, 95% CI: 1.73–65.27, P = 0.01) with rTSA. In the mid-term follow-up, the overall revision rate showed no difference between aTSA and rTSA, with a pooled OR of 0.33 (95% CI: 0.07–1.57, P = 0.16). Conclusion A better ROM was achieved after aTSA than after rTSA. There was no difference in the revision rate at mid-term follow-up between aTSA and rTSA. Glenoid loosening was more common with aTSA, and scapula notching with rTSA. Level of evidence: Level IV, Meta-analysis.


2018 ◽  
Vol 2 ◽  
pp. 247154921775047
Author(s):  
Joaquin Sanchez-Sotelo ◽  
Ngoc Tram V Nguyen ◽  
Mark Morrey

Background: High rates of radiographic loosening have been reported with various glenoid designs. Many available designs sacrifice most of the bone at the central portion of the glenoid vault, creating large areas of deficiency when revision becomes necessary. The purpose of this study was to report the 2- to 5-year outcome of shoulder arthroplasty using a bone-preserving all-polyethylene glenoid components with self-pressurizing pegs. Methods: Between August 2011 and December 2014, 202 consecutive anatomic total shoulder arthroplasties (TSAs) were performed by a single surgeon with implantation of a self-pressurizing cemented pegged glenoid component in 190 patients (12 patients had both shoulders replaced). Patients were followed up prospectively and evaluated for pain, motion, strength, American Shoulder and Elbow Surgeons (ASES) scores, and radiographic changes. The mean follow-up time was 2.7 (2–5) years. Results: TSA improved pain and function reliably. At the most recent follow-up, 94% of the shoulders had no or mild pain. Motion included 154 ± 25° of elevation, 68 ± 18° of external rotation, and median internal rotation to T10 (range, iliac crest to T4). The most recent average ASES score was 82 ± 15 points. Early postoperative radiographs showed no radiolucent lines. No humeral or glenoid component was considered radiographically loose at the most recent follow-up. Complications requiring reoperation included subscapularis insufficiency (4), posterior instability (2), deep infection (1), stiffness (1), and a painful loose body (1). No components were revised for loosening. Conclusions: Anatomic TSA using a cemented bone-preserving all-polyethylene pegged self-pressurizing glenoid component provided satisfactory clinical outcomes and survival at 2 to 5 years.


Joints ◽  
2021 ◽  
Author(s):  
Riccardo Luigi Alberio ◽  
Marco Landrino ◽  
Paolo Fornara ◽  
Federico Alberto Grassi

Abstract Purpose This article compares short-term outcomes of two series of patients, who underwent reverse total shoulder arthroplasty (RTSA) with two different implants, both based on Grammont's principles: the Delta III (D-3) and the Delta Xtend (D-XT) prostheses. Methods The D-3 group included a consecutive series of 26 patients (mean age 75 years), that were treated between 2000 and 2006; the D-XT group included a consecutive series of 31 patients (mean age 72.5 years), for a total of 33 implants performed between 2011 and 2015. In both groups the most common diagnoses were cuff tear arthropathy (18 and 22 shoulders, respectively) and malunion of proximal humerus fractures (3 and 5). All procedures were performed by the same surgeon. Constant–Murley score (CMS) was used to assess clinical and functional outcomes. Radiographic evaluation included the true anteroposterior and axillary views. Results Twenty-three patients of the D-3 group and 22 patients (24 shoulders) of the D-XT group were evaluated at a mean follow-up of 42 months (range 26–84) and 44 months (range 26–66), respectively. Four complications occurred in the D-3 group (1 partial deltoid detachment, 1 dislocation, and 2 glenoid component loosening), while one early postoperative infection occurred in the D-XT group. Increases in elevation and CMS between preoperative and postoperative period were observed in both groups; only the D-XT group showed a slight improvement in rotations. The incidence of scapular notching was significantly different between the two groups: 100% for D-3 and 22.2% for D-XT in patients with a minimum follow-up of 5 years. Conclusion Prosthetic design evolution and greater acquaintance with this surgery have undoubtedly led to an improvement in short-term outcomes with second generation implants of RTSA. Future studies will have to ascertain whether newer implants, relying on biomechanical solutions alternative to Grammont's original concept, might provide additional advantages and minimize drawbacks.


2021 ◽  
pp. 155633162110408
Author(s):  
Ahmed Haleem ◽  
Phelopater Sedrak ◽  
Chetan Gohal ◽  
George S. Athwal ◽  
Moin Khan ◽  
...  

Background: Hybrid glenoid components in total shoulder arthroplasty (TSA) utilize both polyethylene and metal components to provide short-term stability and long-term biologic fixation through bone ingrowth. Questions/Purpose: We sought to systematically review the literature for studies that assessed outcomes of TSA performed using hybrid glenoid components. Methods: PubMed, Medline, Cumulative Index to Nursing and Allied Health Literature (CINAHL), and Embase were searched systematically for articles measuring clinical and patient-reported outcomes and rates of complication and revision following TSA using a hybrid glenoid component. Results: Seven studies with 593 shoulders were included in this review. The mean age of patients was 65 ± 1 years, and 46% of the population was male. Mean follow-up was 50 months (4.2 years). The overall complication rate was 7% and rate of revision was 2.5%; glenoid radiolucency was present in 33% of shoulders at mean follow-up of 50 months. Mean improvements in forward elevation, external rotation, internal rotation score, and abduction were 49°, 28°, 2 points, and 42°, respectively. Mean improvements in Constant, American Shoulder and Elbow Surgeons (ASES), and University of California, Los Angeles (UCLA) scores were 36 points, 52 points, and 17 points, respectively. Conclusion: Our review found that TSA using hybrid glenoid components results in low rates of complication and revision at early follow-up. Long-term studies are warranted to understand more fully the role of hybrid glenoid components in TSA.


2021 ◽  
Vol 10 (24) ◽  
pp. 5773
Author(s):  
Maciej J. K. Simon ◽  
Helen Crofts ◽  
Treny Sasyniuk ◽  
Kayla Johnston ◽  
Derek Plausinis ◽  
...  

Background: Malpositioning of the glenoid component in total shoulder arthroplasty (TSA) remains the primary source of loosening. The purpose of this study is firstly, to quantify postoperative glenoid component position in patients having a TSA and secondly, to explore whether glenoid component radiolucency is associated with glenoid position, clinical outcomes and patient-reported measures in the short-term (two year) follow-up period. Methods: This study was a sub-study of a larger clinical trial that included patients who underwent a TSA and who were randomized into two different glenoid types with a minimum two-year follow-up period. Post-operative radiographic assessments (six weeks and two years) were used to measure glenoid component position (version, inclination, offset) and humeral head centering anterior–posterior (AP) and superior–inferior (SI), and to assess glenoid component radiolucent scoring (modified Lazarus). Pre-operative X-rays were used to measure glenoid version, inclination and Walch classification. Patient-reported measures (PROMs) included the EQ-5D health slider and the Western Ontario Osteoarthritis (WOOS) and American Shoulder and Elbow Surgeons (ASES) score and were captured at baseline and two years postoperative. Clinical outcomes including range of motion and complications were also documented. Statistical analysis included t-tests and regression modeling. Results: Ninety-one patients with an average age of 69.9 ± 6.2 years were included in this study. Glenoid component position improved significantly in version (−19.4 ± 8.6° to −17.7 ± 8.5°; p < 0.045) and inclination (11.5 ± 7.1° to 5.9 ± 6.3°; p < 0.00001) from preoperative to six weeks postoperative. Glenoid component offset in SI and humeral head centering in AP remained unchanged throughout the follow-up. Radiolucency (Lazarus classification) was recorded in 21 cases (17.3%) with a Lazarus score of 1 (15 cases) and 2 (6 cases). The EQ-5D health slider, WOOS and ASES, and ROM confirmed continuous improvements from the preoperative scores to the two-year follow-up (p < 0.05). Regression models showed no correlation between glenoid component radiolucency at two years and the postoperative week six glenoid component position; however, female gender was a significant variable. Conclusion: Glenoid component changes from its original native glenoid were observed following TSA. Glenoid inclination was improved more than version from baseline, and the humeral head remained well-centered in AP and SI at two years. Radiolucency of the glenoid at two years is not negatively associated with PROMs or component position; however, female gender was identified as a significant predictor and warrants further investigation. Complications are not associated with glenoid position or radiolucency, but longer-term follow-up is required.


2018 ◽  
Vol 26 (3) ◽  
pp. 230949901878952
Author(s):  
Eduard Alentorn-Geli ◽  
Nathan R Wanderman ◽  
Andrew T Assenmacher ◽  
John W Sperling ◽  
Robert H Cofield ◽  
...  

Background: Revision of failed anatomic total shoulder arthroplasty or hemiarthroplasty is a challenging procedure. Restoring adequate soft tissue balance in the revision setting can be particularly problematic. When persistent posterior instability is encountered in the revision setting, options include changing component position or size, posterior capsular plication (PCP), or conversion to a reverse arthroplasty. The purpose of this study was to report the clinical and radiographic outcomes, complications, and reoperations of PCP performed in the setting of revision anatomic shoulder arthroplasty. Patients and Methods: Between 1975 and 2013, 15 patients (16 shoulders) had PCP during revision anatomic shoulder arthroplasty. Indications for revision arthroplasty included posterior instability in 15, glenoid loosening in 3, polyethylene wear in 2, and glenoid erosion in 1 shoulder. The mean (standard deviation (SD)) age was 60.1 (12.6) years, and the median (range) follow-up was 68 (2–228) months. A retrospective chart review was conducted to obtain all data. Results: At the last follow-up, nine shoulders (56%) had absence of posterior radiographic subluxation. Five (31%) cases underwent reoperation due to persistent posterior instability. Complications were observed in seven (44%) cases. Complete pain relief was achieved in four (25%) shoulders. The mean (SD) postoperative forward flexion, external rotation, and the American Shoulder and Elbow Surgeons score were 110° (41°), 40° (29°), and 62.1 (21.9), respectively. Results were excellent in two (13%), satisfactory in seven (44%), and unsatisfactory in seven (44%) shoulders. Conclusions: PCP to correct posterior instability during revision anatomic shoulder arthroplasty had an unacceptably high failure rate. In these circumstances, consideration should instead be given to conversion to a reverse shoulder arthroplasty.


Author(s):  
W Swieszkowski ◽  
P Bednarz ◽  
P J Prendergast

Several studies of retrieved glenoid components from total shoulder arthroplasty show an erosion of the rim, surface irregularities, component fracture and wear resulting from polyethylene deformation in vivo. Particles resulting from polyethylene wear might be one of the reasons for the very high rate of glenoid component loosening found clinically. Because wear can be the result of high contact stresses, the aim of this study is to find out whether or not contact stresses are high enough to cause wear of the glenoid component and what influence the component type and geometry have on polyethylene contact stresses for different humerus abduction angles. Elasticity theory is used in a parametric study of contact stresses in several glenoid component designs. A finite element method is used to confirm the accuracy of the analytical solution. The analysis shows that the peak stress generated in glenoid components under conditions of normal living can be as high as 25 MPa; since this exceeds the polyethylene yield strength, wear and also cold flow of the components can be expected. It is predicted that more conforming components have lower contact stresses, which might result in lower wear rate and less cold flow. It is also found that a metal-backed component promotes higher contact stresses than an all-polyethylene component with the same total thickness, therefore it can be expected that metal-backed components have inferior wear properties.


Sign in / Sign up

Export Citation Format

Share Document