scholarly journals Left ventricular performance of pulmonary atresia with intact ventricular septum after right heart bypass surgery

2004 ◽  
Vol 128 (5) ◽  
pp. 710-717 ◽  
Author(s):  
Yoshihisa Tanoue ◽  
Hideaki Kado ◽  
Taketoshi Maeda ◽  
Yuichi Shiokawa ◽  
Naoki Fusazaki ◽  
...  
2000 ◽  
Vol 10 (1) ◽  
pp. 60-63 ◽  
Author(s):  
Robert M. Freedom ◽  
Shi-Joon Yoo ◽  
Alexander Javois

AbstractA patient with pulmonary atresia and intact ventricular septum was found to have a right ventricular-dependent coronary circulation. In this infant both coronary arteries lacked their normal proximal connection with the aorta, perhaps the most egregious form of this prejudicial coronary circulation. Even more interesting was a direct collateral vessel originating from the descending thoracic aorta and connecting with the coronary circulation. This patient has undergone bilateral modified Blalock-Taussig shunts, and left ventricular function seems preserved.


1992 ◽  
Vol 2 (4) ◽  
pp. 361-366 ◽  
Author(s):  
Luciano Daliento ◽  
Roldano Scognamiglio ◽  
Gaetano Thiene ◽  
Anita Hegerty ◽  
Siew Yen Ho ◽  
...  

SummaryWe studied 11 patients with pulmonary atresia and intact ventricular septum who died at ages ranging from one day to three years. All but two neonates died after surgery. Pre-surgical catheterization with left and right cineventriculography was performed in nine patients, and quantitative parameters were calculated. By histologic examination of transverse transmural sections, the incidence and extent of myocardial ischemia or infarction were determined, as well as the percentage area per field occupied by vessels, myocytes orientated longitudinally or transversely, interstitial space, and disarrayed fibers. Comparable sections were obtained from six normal neonates to constitute a control group. Myocardial ischemia or infarction were frequent complications. Morphometric analysis demonstrated a significant difference between the control group and the patients with regard to the percentage of myocytes (longitudinal and transverse), the percentage of area occupied by myocardial disarray, and the presence of fibrosis. The highest values for the proportion of disarray were seen in those patients with small right ventricles. The percentage of myocytes varied, but the highest degree of disarray always correlated with the lowest percentage of myocytes. The highest percentage value of left ventricular disarray was associated with the lowest ratio of left ventricular mass to end diastolic volume (inadequate hypertrophy). The lowest indices of contractility and left ventricular pump function were associated with myocytes less than 55% of normal. A linear correlation was found between the percentage area of fibrosis and the ratio of systolic pressure to end systolic volume in the left ventricle, arid between fibrosis and ejection fraction. Values for fibrosis exceeding 15% were associated with decreased functional indices. Disarray, therefore, seems to express a primary inability of myocardium to respond to anomalous overload with adequate hypertrophy and/or hyperplasia.


2018 ◽  
Vol 38 (4) ◽  
pp. 218-225
Author(s):  
Emir Yonas ◽  
Raymond Pranata ◽  
Nuvi Nusarintowati

Introduction: Pulmonary atresia with an intact ventricular septum is a condition that is characterized by a complete obstruction to right ventricular outflow with varying degrees of right ventricular and tricuspid valve hypoplasia. This condition is uniformly fatal if untreated. In this case report, we present a case of a neonate with a pulmonary atresia with intact ventricular septum Case Presentation: A 2 days-old female Indonesian newborn was referred to our facility. The newborn was delivered from a G4P3A0 mother with a gestational age of 39 weeks (term delivery). Chest x-ray done at the referring facility is significant for a seemingly right heart hypertrophy, casting a “boot-shaped” appearance of the right heart border. Laboratory results done at the referring facility is significant for a neutrophilia of 82% and lymphocytopenia of 13% An episode of hypoglycemia was reported on referring facility with a blood sugar level of 50 mg/dl. Multiple episodes of cyanosis were reported at referring facility, CPAP was administered but the improvement was limited. Pulse oximetry averaged between 72-80% at the referring facility. Physical examina­tion shows an actively moving neonate, with a strong cry. Perioral cyanosis was seen. Vital signs were as follows; heart rate 128 x / minute, temperature 37oC, respiratory rate 54 x / minute, pulse oximetry 74%, capillary refill time < 3 seconds. The rest of the physical examination was within normal limits. Laboratory result on admission at our facility is significant for low hematocrit, low erythrocyte count, leukopenia with neutrophilia and thrombocytopenia. Patient was admitted to NICU and given CPAP. Echocardiography 2 days upon arrival at our facility reveals a patent ductus arteriosus with the pressure of 4-5 mmHg and diameter of 0.3 cm, no forward flow from the right ventricle to the pulmonary artery, doppler mode demonstrated pulmonary artery filling from ductus arteriosus. The rest of the findings were within normal limits. Conclusion: Pulmonary atresia with an intact ventricular septum is a condition that relies on the patent ductus arteriosus for pulmonary blood supply, the patency of it is of paramount importance.   Abstrak PENDAHULUAN: Atresia arteri pulmonalis dengan septum ventrikel yang utuh merupakan kondisi yang dikarakterisasikan dengan sumbatan total pada right ventricular outflow dengan berat hipoplasia ventrikel kanan dan trikuspid kanan yang beratnya bervariasi. Pada umumnya kondisi tersebut fatal apabila tidak ditangani. Pada laporan kasus ini, kami melaporkan suatu kasus neonates dengan atresia arteri pulmonalis dengan septum ventrikel yang utuh. PRESENTASI KASUS: Neonatus perempuan berumur 2 hari dirujuk ke rumah sakit kami. Bayi dilahirkan dari G4P3A0 usia kehamilan 39 minggu. Ronsen thoraks yang dilakukan oleh fasilitas kesehatan yang merujuk memperlihatkan hipertrofi jantung kanan serta bentuk “boot-shaped” pada batas jantung kanan. Hasil laboratorium pada fasilitas kesehatan tersebut menunjukan neutrofilia dan limfositopenia. Terdapat juga riwayat hipoglikemi. Episode sianosis berulang terjadi pada fasilitas kesehatan yang merujuk. Pemasangan CPAP kurang membuahkan hasil dengan saturasi O2 72-80% ketika tiba pada rumah sakit kami. Pemeriksaan fisik menunjukan tangis kuat dan gerak aktif dengan sianosis perioral. Detak jantung 128 kali/menit, suhu 37oC, laju naas 54 kali/menit, oksimetri nadi 74% dan waktu isi kapiler <3 detik. Pemeriksaan laboratorium saat pasien dating menunjukan hematocrit, hitung eritrosit, leukosit dan thrombosit yang rendah. Pasien dirawat di NICU dan diberikan CPAP. Ekokardiografi 2 hari kemudian menunjukan duktus arteriosus patent dengan tekanan 4-5 mmHg dan diameter 0.3 cm, tidak ada aliran maju dari ventrikel kanan kepada arteri pulmonalis, mode Doppler menunjukan pengisian arteri pulmonalis dari duktus arteriosus. Pemeriksaan lainnya dalam batas normal. KESIMPULAN: Atresia arteri pulmonalis dengan septum ventrikel yang utuh merupakan suatu kondisi dimana aliran darah menuju paru bergantung pada duktus arteriosus yang paten sehingga patensi daripada duktus tersebut sangatlah penting


Sign in / Sign up

Export Citation Format

Share Document