Technical Success and Safety of Retrieval of the G2 Filter in a Prospective, Multicenter Study

2009 ◽  
Vol 20 (11) ◽  
pp. 1449-1453 ◽  
Author(s):  
Christoph A. Binkert ◽  
Alain T. Drooz ◽  
James G. Caridi ◽  
Mark J. Sands ◽  
Haraldur Bjarnason ◽  
...  
2021 ◽  
Vol 10 (13) ◽  
pp. 2936
Author(s):  
Hirofumi Kogure ◽  
Hironari Kato ◽  
Kazumichi Kawakubo ◽  
Hirotoshi Ishiwatari ◽  
Akio Katanuma ◽  
...  

Background: Endoscopic biliary stent placement is the standard of care for biliary strictures, but stents across the papilla are prone to duodenobiliary reflux, which can cause stent occlusion. Preliminary studies of “inside stents” placed above the papilla showed encouraging outcomes, but prospective data with a large cohort were not reported. Methods: This was a prospective multicenter registry of commercially available inside stents for benign and malignant biliary strictures. Primary endpoint was recurrent biliary obstruction (RBO). Secondary endpoints were technical success of stent placement and removal, adverse events, and stricture resolution. Results: A total of 209 inside stents were placed in 132 (51 benign and 81 malignant) cases with biliary strictures in 10 Japanese centers. During the follow-up period of 8.4 months, RBO was observed in 19% of benign strictures. The RBO rate was 49% in malignant strictures, with the median time to RBO of 4.7 months. Technical success rates of stent placement and removal were both 100%. The adverse event rate was 8%. Conclusion: This prospective multicenter study demonstrated that inside stents above the papilla were feasible in malignant and benign biliary strictures, but a randomized controlled trial is warranted to confirm its superiority to conventional stents across the papilla.


2019 ◽  
Author(s):  
M Maida ◽  
G Morreale ◽  
E Sinagra ◽  
M Manganaro ◽  
D Schillaci ◽  
...  

2013 ◽  
Vol 154 (21) ◽  
pp. 825-833
Author(s):  
Zoltán Döbrönte ◽  
Mária Szenes ◽  
Beáta Gasztonyi ◽  
Lajos Csermely ◽  
Márta Kovács ◽  
...  

Introduction: Recent guidelines recommend routine pulse oximetric monitoring during endoscopy, however, this has not been the common practice yet in the majority of the local endoscopic units. Aims: To draw attention to the importance of the routine use of pulse oximetric recording during endoscopy. Method: A prospective multicenter study was performed with the participation of 11 gastrointestinal endoscopic units. Data of pulse oximetric monitoring of 1249 endoscopic investigations were evaluated, of which 1183 were carried out with and 66 without sedation. Results: Oxygen saturation less than 90% was observed in 239 cases corresponding to 19.1% of all cases. It occurred most often during endoscopic retrograde cholangiopancreatography (31.2%) and proximal enteroscopy (20%). Procedure-related risk factors proved to be the long duration of the investigation, premedication with pethidine (31.3%), and combined sedoanalgesia with pethidine and midazolam (34.38%). The age over 60 years, obesity, consumption of hypnotics or sedatives, severe cardiopulmonary state, and risk factor scores III and IV of the American Society of Anestwere found as patient-related risk factors. Conclusion: To increase the safety of patients undergoing endoscopic investigation, pulse oximeter and oxygen supplementation should be the standard requirement in all of the endoscopic investigation rooms. Pulse oximetric monitoring is advised routinely during endoscopy with special regard to the risk factors of hypoxemia. Orv. Hetil., 2013, 154, 825–833.


Sign in / Sign up

Export Citation Format

Share Document