Porous flexible polyaniline/polyvinylidene fluoride composite film for trace-level NH3 detection at room temperature

2020 ◽  
Vol 271 ◽  
pp. 127798 ◽  
Author(s):  
Pengyu Yang ◽  
Dawu Lv ◽  
Wenfeng Shen ◽  
Tieyi Wu ◽  
Ye Yang ◽  
...  
The Analyst ◽  
2021 ◽  
Author(s):  
Jialin Yang ◽  
Ding Wang ◽  
Ming Li ◽  
Haitao Yu ◽  
Pengcheng Xu ◽  
...  

The trace-level detection to harmful NO2 gas at room-temperature is very important for environmental protection and public health. This paper reports the resonant-gravimetric detection of ppb-level NO2 at room-temperature using...


2014 ◽  
Vol 875-877 ◽  
pp. 82-86
Author(s):  
Xian Li ◽  
Ya Dong Jiang ◽  
Hui Ling Tai ◽  
Guang Zhong Xie ◽  
Wen Chao Dan

Formaldehyde, a colorless and pungent-smelling gas, had been confirmed be a huge threat to people health. The detection of formaldehyde was necessary and important at room temperature. Sprayed P3HT/InSnO composite film based on organic thin film transistors (OTFT) was fabricated to detect formaldehyde at room temperature in this paper. The results showed that P3HT/ InSnO-OTFT showed better response and recovery to HCHO compared with P3HT-OTFT at room temperature.


Polymers ◽  
2021 ◽  
Vol 13 (18) ◽  
pp. 3077
Author(s):  
Rima D. Alharthy ◽  
Ahmed Saleh

In this study, we developed a new chemi-resistive, flexible and selective ammonia (NH3) gas sensor. The sensor was prepared by depositing thin film of polyaniline-cobalt ferrite (PAni-CoFe2O4) nanocomposite on flexible polyethylene terephthalate (PET) through an in situ chemical oxidative polymerization method. The prepared PAni-CoFe2O4 nanocomposite and flexible PET-PAni-CoFe2O4 sensor were evaluated for their thermal stability, surface morphology and materials composition. The response to NH3 gas of the developed sensor was examined thoroughly in the range of 1–50 ppm at room temperature. The sensor with 50 wt% CoFe2O4 NPs content showed an optimum selectivity to NH3 molecules, with a 118.3% response towards 50 ppm in 24.3 s response time. Furthermore, the sensor showed good reproducibility, ultra-low detection limit (25 ppb) and excellent flexibility. In addition, the relative humidity effect on the sensor performance was investigated. Consequently, the flexible PET-PAni-CoFe2O4 sensor is a promising candidate for trace-level on-site sensing of NH3 in wearable electronic or portable devices.


RSC Advances ◽  
2019 ◽  
Vol 9 (2) ◽  
pp. 738-738
Author(s):  
Zhao Li ◽  
Li Zhang ◽  
Rong Qi ◽  
Fan Xie ◽  
Shuhua Qi

Correction for ‘Improved lateral heat spreading performance for polyvinylidene fluoride composite film comprising silver nanowire in light-emitting diode’ by Zhao Li et al., RSC Adv., 2016, 6, 35844–35891.


2019 ◽  
Vol 43 (7) ◽  
pp. 3128-3138 ◽  
Author(s):  
Dhiraj Kumar Rana ◽  
Suresh Kumar Singh ◽  
Shovan Kumar Kundu ◽  
Subir Roy ◽  
S. Angappane ◽  
...  

The higher values of magneto-dielectric coupling is observed in flexible multiferroic polyvinylidene fluoride (PVDF) nanocomposites doped with nickel ferrite (NFO) nanoparticles.


Sign in / Sign up

Export Citation Format

Share Document