scholarly journals SCASP: a simple and robust sodium dodecyl sulfate-aided sample preparation method for proteomic research

2021 ◽  
pp. 100051
Author(s):  
Guohong Gan ◽  
Xiao Xu ◽  
Xi Chen ◽  
Xiu-Fang Zhang ◽  
Jinling Wang ◽  
...  
2012 ◽  
Vol 84 (6) ◽  
pp. 2862-2867 ◽  
Author(s):  
Jian-Ying Zhou ◽  
Geoffrey P. Dann ◽  
Tujin Shi ◽  
Lu Wang ◽  
Xiaoli Gao ◽  
...  

2006 ◽  
Vol 353 (2) ◽  
pp. 204-208 ◽  
Author(s):  
Frederick R. Taylor ◽  
Holly L. Prentice ◽  
Ellen A. Garber ◽  
Hans A. Fajardo ◽  
Elena Vasilyeva ◽  
...  

Author(s):  
Jian-Shing Luo ◽  
Hsiu Ting Lee

Abstract Several methods are used to invert samples 180 deg in a dual beam focused ion beam (FIB) system for backside milling by a specific in-situ lift out system or stages. However, most of those methods occupied too much time on FIB systems or requires a specific in-situ lift out system. This paper provides a novel transmission electron microscopy (TEM) sample preparation method to eliminate the curtain effect completely by a combination of backside milling and sample dicing with low cost and less FIB time. The procedures of the TEM pre-thinned sample preparation method using a combination of sample dicing and backside milling are described step by step. From the analysis results, the method has applied successfully to eliminate the curtain effect of dual beam FIB TEM samples for both random and site specific addresses.


Author(s):  
Swaminathan Subramanian ◽  
Khiem Ly ◽  
Tony Chrastecky

Abstract Visualization of dopant related anomalies in integrated circuits is extremely challenging. Cleaving of the die may not be possible in practical failure analysis situations that require extensive electrical fault isolation, where the failing die can be submitted of scanning probe microscopy analysis in various states such as partially depackaged die, backside thinned die, and so on. In advanced technologies, the circuit orientation in the wafer may not align with preferred crystallographic direction for cleaving the silicon or other substrates. In order to overcome these issues, a focused ion beam lift-out based approach for site-specific cross-section sample preparation is developed in this work. A directional mechanical polishing procedure to produce smooth damage-free surface for junction profiling is also implemented. Two failure analysis applications of the sample preparation method to visualize junction anomalies using scanning microwave microscopy are also discussed.


Sign in / Sign up

Export Citation Format

Share Document