Proficiency test for effective area determination of a pneumatic pressure balance in Mexico

Measurement ◽  
2014 ◽  
Vol 55 ◽  
pp. 227-230
Author(s):  
Jorge Torres-Guzman ◽  
Jesus Aranzolo-Suarez
2019 ◽  
Vol 21 (3) ◽  
pp. 203
Author(s):  
Adindra Vickar Ega ◽  
R.Rudi Anggoro Samodro

<p>To provide calibration services for pressure measuring devices, SNSU-BSN has several piston-cylinder standard that may traceable to different National Metrology Institute (NMIs). Non-full range calibration of pressure balance has been performed to evaluate the consistency of calibration results between those standard, especially for establishing self-traceability in the future. In this research, a piston-cylinder unit S/N 1926 with medium pressure range of 1750 kPa, was calibrated with low pressure range S/N 978 of 350 kPa and high pressure range S/N 1054 of 7000 kPa. The calibration was performed with cross-float method to evaluate the effective area of piston-cylinder at null pressure and reference temperature of 20⁰C (<em>A<sub>0,20</sub></em>) and distortion coefficient (λ) as the 1926 main parameters. The obtained value, respectively are (1.961 166 × 10<sup>-4</sup> ± 4.4 × 10<sup>-9</sup>) m<sup>2 </sup>and (-1.67 × 10<sup>-12</sup> ± 9.4 × 10<sup>-13</sup>) Pa<sup>-1 </sup>from 978 and (1.961166 × 10<sup>-4</sup> ± 5.1 × 10<sup>-9</sup>) m<sup>2</sup> and (-1.58 × 10<sup>-12</sup> ± 8.4 × 10<sup>-13</sup>) Pa<sup>-1 </sup>from 1054. The result of 1926 from both methods shows good conformity with Normalized Error (En) of 0.0007 and 0.069, respectively. Linearity of effective area changes to the pressure is very consistent in both low and high pressure range. Validation results by using PTB-Germany results, shows the relative different for <em>A<sub>0</sub></em> and <em>λ</em> obtained are less than 0,1 × 10<sup>-6</sup> and 6%,respectively. Therefore, the pneumatic pressure balance of SNSU-BSN is traceable, consistent with each other and capable for disseminating the pressure unit along all primary pressure standard owned with high agreement compared to those of other advance NMIs.</p>


ACTA IMEKO ◽  
2021 ◽  
Vol 10 (1) ◽  
pp. 271
Author(s):  
Ahmed Salama Hashad ◽  
Wladimir Sabuga ◽  
Sven Ehlers ◽  
Thomas Bock

Experimental methods using different pressure standards were applied to verify theoretical results obtained for the effective area of the piston-cylinder assembly (PCA) and for pressures measured with a force-balanced piston gauge (FPG). The theoretical effective area was based on the PCA’s dimensional properties defined via diameter, straightness and roundness measurements of the piston and cylinder, derived by gas-flow modelling using principles of the rarefied gas dynamics, and presented as two values: one obtained for absolute and the other for gauge pressure operation mode. Both values have a relative standard uncertainty of 5×10<sup>-6</sup>. The experimental methods chosen were designed to cover the entire operating pressure range of the FPG from 3 Pa to 15 kPa. Comparisons of the FPG with three different PTB pressure standards operated in different pressure ranges – a pressure balance, a mercury manometer and a static expansion system – were performed using the cross-float method and by a direct comparison of the generated pressures. For the theoretical and experimental effective area, as well as for pressures generated by the FPG and the reference standards, all the results demonstrated full agreement within the expanded uncertainties of the standards.


Author(s):  
Jasveer Singh ◽  
Neha Bura ◽  
Kapil Kaushik ◽  
Lakshmi Annamalai Kumaraswamidhas ◽  
Nita Dilawar Sharma

It is well established that the estimation of measurement uncertainty is vital for the validation of any measurement and is an essential parameter of quality assurance. Apart from the conventional technique of law of propagation of uncertainty (LPU), which has many limitations, Monte Carlo simulation (MCS) technique has become an essential tool for the estimation of measurement uncertainty in various fields of metrology. The most critical factor in MCS is the generation of random numbers of the input quantities according to their probability distributions. The number of Monte Carlo trials to generate these random numbers significantly affects the results. In particular, the required number of trials is also affected by the parameter for which the uncertainty is to be estimated. Hence, in the current paper, the effect of selection of the number of trials on the random number generation and the resulting output in terms of standard deviation (SD) is investigated for the uncertainty in the effective area of a pneumatic reference pressure standard (NPLI-4) at the CSIR-National Physical Laboratory of India. The simulation results thus obtained are compared amongst themselves, with an adaptive approach as well as with the experimental results. The outcomes are analyzed and discussed in detail.