scholarly journals An efficient method to capture the impact of total knee replacement on a variety of simulated patient types: A finite element study

2016 ◽  
Vol 38 (9) ◽  
pp. 959-968 ◽  
Author(s):  
Noel Conlisk ◽  
Colin R. Howie ◽  
Pankaj Pankaj
2021 ◽  
Author(s):  
Morshed Khandaker ◽  
Onur Can Kalay ◽  
Fatih Karpat ◽  
Amgad Haleem ◽  
Wendy Williams ◽  
...  

Author(s):  
Balakrishna Adhikari ◽  
BN Singh

In this paper, a finite element study is conducted using the Green Lagrange strain field based on vonKarman assumptions for the geometric nonlinear static and dynamic response of the laminated functionally graded CNT reinforced (FG-CNTRC) composite plate. The governing equations for determining the nonlinear static and dynamic behavior of the FG-CNTRC plate are derived using the Lagrange equation of motion based on Reddy's higher order theory. Using the direct iteration technique, the nonlinear eigenvalues for analyzing the free vibration response are obtained and the nonlinear dynamic responses of the FG-CNTRC plate are encapsulated based on the nonlinear Newmark integration scheme. The impact of the amplitude of vibration on mode switching phenomena and the consequence of the duration of the pulse on the free vibration regime of the plate are outlined. Also, the effect of time dependent loads is studied on the normal stresses of the plate. Furthermore, the impact on the nonlinear static and dynamic response of the laminated FG-CNTRC plate of various parameters such as span-thickness ratio (b/h ratio), aspect ratio (a/b ratio), different edge constraints, CNT fiber gradation, etc. are also studied.


1992 ◽  
Vol 25 (12) ◽  
pp. 1413-1424 ◽  
Author(s):  
R.L. Rakotomanana ◽  
P.F. Leyvraz ◽  
A. Curnier ◽  
J.H. Heegaard ◽  
P.J. Rubin

2018 ◽  
Vol 77 ◽  
pp. 146-154 ◽  
Author(s):  
Liming Shu ◽  
Ko Yamamoto ◽  
Jiang Yao ◽  
Prabhav Saraswat ◽  
Yao Liu ◽  
...  

Author(s):  
Morshed Khandaker ◽  
Onur Can Kalay ◽  
Fatih Karpat ◽  
Amgad Haleem ◽  
Wendy Williams ◽  
...  

Abstract A method to improve the mechanical fixation of a total knee replacement (TKR) implant is clinically important and is the purpose of this study. More than one million joint replacement procedures are performed in people each year in the United States, and experts predict the number to increase six-fold by the year 2030. Whether cemented or uncemented, joint prostheses may destabilize over time and necessitate revision. Approximately 40,000 hip arthroplasty surgeries have to be revised each year and the rate is expected to increase by approximately 140% (and by 600% for total knee replacement) over the next 25 years. In veterinary surgery, joint replacement has a long history and the phenomenon of surgical revision is also well recognized. For the betterment of both people and animals, improving the longevity of arthroplasty devices is of the utmost clinical importance, and towards that end, several strategies are under investigation. One approach that we explore in the present research is to improve the biomechanical performance of cemented implant systems by altering the implant surface architecture in a way that facilitates its cement bonding capacity. Beginning with the Charnley system, early femoral stems were polished smooth, but a number of subsequent designs have featured a roughened surface — created with bead or grit blasting — to improve cement bonding. Failure at the implant-cement interface remains an issue with these newer designs, leading us to explore in this present research an alternate, novel approach to surface alteration — specifically, laser microgrooving. This study used various microgrooves architectures that is feasible using a laser micromachining process on a tibia tray (TT) for the goat TKR. Developing the laser microgrooving (LM) procedure, we hypothesized feasibility in producing parallel microgrooves of precise dimensions and spacing on both flat and round metallic surfaces. We further hypothesized that laser microgrooving would increase surface area and roughness of the cement interface of test metallic implants and that such would translate into an improved acute mechanical performance as assessed in vitro under both static and cyclic loads. The objective was to develop a computational model to determine the effect of LIM on the tibial tray to the mechanical stimuli distributions from implant to bone using the finite element method. This study designed goat TT 3D solid model from a computer topography (CT) images, out of which three different laser microgrooves were engraved on TT sample by varying depth, height and space between two adjacent grooves. The simulation test results concluded that microgrooves acchitecures positively influence microstrain behavior around the implant/bone interfaces. There is a higher amount of strain observed for microgroove implant/bone samples compared to non-groove implant/bone samples. Thus, the laser-induced microgrooves have the potential to be used clinically in TKR components.


2005 ◽  
Vol 38 (2) ◽  
pp. 323-331 ◽  
Author(s):  
Jason P. Halloran ◽  
Anthony J. Petrella ◽  
Paul J. Rullkoetter

Sign in / Sign up

Export Citation Format

Share Document