scholarly journals Development of an ecologically safe method for improved feather wastes biodegradation using Thermophilic actinomycetes

2009 ◽  
Vol 25 ◽  
pp. S151-S152
Author(s):  
E. Vasileva-Tonkova ◽  
A. Gousterova ◽  
M. Nustorova ◽  
G. Neshev
Crisis ◽  
2019 ◽  
Vol 40 (4) ◽  
pp. 257-264 ◽  
Author(s):  
Thomas Niederkrotenthaler ◽  
Benedikt Till

Abstract. Background: Little is known about presenting problems of primary posters (i.e., posters opening the thread) and their responders in nonprofessional against-suicide and pro-suicide message boards. Aims: We aimed to compare problems described in suicide message boards between different types of users (primary posters and respondents) and between against-suicide, neutral, and pro-suicide message boards. Method: In all, 1,182 archival threads with 20,499 individual postings from seven nonprofessional suicide message boards supporting an against-suicide, neutral, or pro-suicide attitude were randomly selected. Problems mentioned by primary posters and their respondents were coded with content analysis. Differences between pro-suicide, neutral, and against suicide boards, as well as correlations between primary posters and respondents, were calculated. Results: Interpersonal problems were most frequently mentioned by primary posters in against-suicide threads (40.9%) and less frequently in pro-suicide threads (11.8%; p < .001). In pro-suicide boards, the most frequent stressors were suicide method-related (e.g., how to identify a safe method: 26.2% vs. 2.5% in against-suicide boards, p < .001). Primary posters resembled respondents in terms of presenting problems in pro-suicide boards, but not in against-suicide boards. Limitations: Only self-reported problems were assessed. Conclusion: The results confirm a stronger focus on death than on life among users in pro-suicide message boards, and posters with similar problems meet in pro-suicide boards. The posters appear to clearly emphasize social strains over psychiatric problems compared with some professional settings.


2016 ◽  
pp. 11-18
Author(s):  
L. Nazarenko ◽  
◽  
L. Dubrova ◽  
O. Tarusмna ◽  
◽  
...  

The question of the prevention of pathologies of the labor is currently very important, the answer to them has become the favored formation of «dominants of delivery», choice of the optimal time to delivery, effective and safe method of induction, that promotes the promptness of the female organism and ripening of the cervix, as well as the timely identification and correction of pathological prelмmмnary period. In a review article describes the modern approaches and methods of preventing the pathology of labor activity, presented by the authors ‘ own experience regarding the use of prostaglandins, non-steroidal anti-inflammatory drugs, individual approach to the management of perinatal risk. Key words: childbirth, prevention, induction, prostaglandin, non-steroidal anti-inflammatory drugs.


2019 ◽  
Vol 15 (68) ◽  
pp. 220
Author(s):  
V. Yu. Kassich ◽  
V. V. Ukhovskyi ◽  
O. I. Sosnytskyi ◽  
I. A. Biben ◽  
V. V. Zazharsky ◽  
...  
Keyword(s):  

2018 ◽  
Vol 1 (72) ◽  
pp. 118-122
Author(s):  
Irina Graskova ◽  
◽  
Alla Perfilieva ◽  
Olga Nozhkina ◽  
Igor Klimenkov ◽  
...  
Keyword(s):  

2021 ◽  
pp. 112972982110232
Author(s):  
Sonia D’Arrigo ◽  
Maria Giuseppina Annetta ◽  
Mauro Pittiruti

Persistent withdrawal occlusion is a specific catheter malfunction characterized by inability to withdraw blood through the device while infusion is maintained. The main causes are fibroblastic sleeve and tip malposition (associated or not to venous thrombosis around the tip). All current guidelines recommend infusing vesicant/antiblastic drugs through a central venous port only after assessment of blood return. In PWO, blood return is impossible. We have recently started to assess the intravascular position of the tip and the delivery of the infusion in the proximity of the cavo-atrial junction utilizing transthoracic/subxiphoid ultrasound with the ‘bubble test’. We found that this is an easy, real-time, accurate and safe method for verifying the possibility of using a port for chemotherapy even in the absence of blood return, as it occurs with persistent withdrawal occlusion.


2021 ◽  
Vol 10 (4) ◽  
pp. 887
Author(s):  
Guenther Schneider ◽  
Alexander Massmann ◽  
Peter Fries ◽  
Felix Frenzel ◽  
Arno Buecker ◽  
...  

Background. This paper aimed to prospectively evaluate the safety of embolization therapy of pulmonary arteriovenous malformations (PAVMs) for the detection of cerebral infarctions by pre- and post-interventional MRI. Method One hundred and five patients (male/female = 44/61; mean age 48.6+/−15.8; range 5–86) with pre-diagnosed PAVMs on contrast-enhanced MRA underwent embolization therapy. The number of PAVMs treated in each patient ranged from 1–8 PAVMs. Depending on the size and localization of the feeding arteries, either Nester-Coils or Amplatzer vascular plugs were used for embolization therapy. cMRI was performed immediately before, and at the 4 h and 3-month post-embolization therapy. Detection of peri-interventional cerebral emboli was performed via T2w and DWI sequences using three different b-values, with calculation of ADC maps. Results Embolization did not show any post-/peri-interventional, newly developed ischemic lesions in the brain. Only one patient who underwent re-embolization and was previously treated with tungsten coils that corroded over time showed newly developed, small, diffuse emboli in the post-interventional DWI sequence. This patient already had several episodes of brain emboli before re-treatment due to the corroded coils, and during treatment, when passing the corroded coils, experienced additional small, clinically inconspicuous brain emboli. However, this complication was anticipated but accepted, since the vessel had to be occluded distally. Conclusion Catheter-based embolization of PAVMs is a safe method for treatment and does not result in clinically inconspicuous cerebral ischemia, which was not demonstrated previously.


Author(s):  
Junho Jung ◽  
Bo-Yeon Hwang ◽  
Byung-Soo Kim ◽  
Jung-Woo Lee

Abstract Background The presence of septa increases the risk of Schneiderian membrane perforation during sinus lift procedure, and therefore, the chance of graft failure increases. We present a safe method of managing septa and, in particular, overcoming small and palatally located septa. Methods After the elevation of the flap and the creation of a small bony window positioned anterior to the septum, the Schneiderian membrane is lifted carefully. A thin and narrow osteotome is then placed at the indentation created at the base of the septum, and mobilization of the septum is achieved by gentle malleting. The membrane is again carefully lifted up behind the septum. Results There was one small membrane perforation case in all 16 cases, and none of these patients showed postoperative complications such as implant failure, infection, or maxillary sinusitis. Conclusions This technique is useful for overcoming the problem of maxillary sinus septa hindering the sinus floor elevation procedure, leading to fewer complications.


1983 ◽  
Vol 34 (1) ◽  
pp. 94-95 ◽  
Author(s):  
I. Zahavi ◽  
E.A. Shaffer ◽  
L. Strunin ◽  
D.G. Gall

2014 ◽  
Vol 30 (10) ◽  
pp. 1069-1073 ◽  
Author(s):  
A. Lambertz ◽  
G. Schälte ◽  
J. Winter ◽  
A. Röth ◽  
D. Busch ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document