A thalium-doped sodium iodide well counter for radioactive tracer applications with naturally-abundant 40K

Author(s):  
Andrew J. Parker ◽  
Colin Boxall ◽  
Malcolm J. Joyce ◽  
Paul Schotanus
1980 ◽  
Vol 19 (01) ◽  
pp. 11-15
Author(s):  
G. Roncari ◽  
L. Rapisardi ◽  
L. Conte ◽  
G. Pedroli

A simple model for the study of bone calcium metabolism is proposed. It describes the kinetics of a radioactive tracer in terms of an open single compartment system with an expanding volume for a finite period of time. In addition to the simplicity of the hypotheses introduced, the model is able to give a good description of the biological processes which regulate calcium kinetics. Moreover the functional parameters can be easily calculated, even just graphically. 15 normal subjects and 22 patients affected by various bone diseases were studied. The results were compared with those obtained by using the model proposed by Burkinshaw et al. and the method described by Reeve et al.


2016 ◽  
Author(s):  
Alice Fletcher ◽  
Vikki Poole ◽  
Bhavika Modasia ◽  
Waraporn Imruetaicharoenchoke ◽  
Rebecca Thompson ◽  
...  

2017 ◽  
Author(s):  
Alice Fletcher ◽  
Vikki Poole ◽  
Bhavika Modasia ◽  
Waraporn Imruetaicharoenchoke ◽  
Rebecca Thompson ◽  
...  

2017 ◽  
Author(s):  
Rebecca J. Thompson ◽  
Alice Fletcher ◽  
Hannah Nieto ◽  
Mohammed Alshahrani ◽  
Katie Baker ◽  
...  

2018 ◽  
Author(s):  
Alice Fletcher ◽  
Vikki Poole ◽  
Caitlin Thornton ◽  
Kate Baker ◽  
Rebecca Thompson ◽  
...  

2018 ◽  
Vol 9 (08) ◽  
pp. 20193-20206 ◽  
Author(s):  
Md. Akhlak Bin Aziz ◽  
Md. Faisal Rahman ◽  
Md. Mahidul Haque Prodhan

The paper compares  Lead, Copper and Aluminium as gamma radiation shielding material using both experimental and simulation techniques. Cs- 137 (662KeV), Na-22 (511KeV) and Na- 22(1274KeV) were used as gamma radiation sources and a sodium iodide (NaI) detector was used to detect the radiation. Variations were noted for detected gamma count rates by changing shielding material thickness. In the experimental approach, thickness was varied by placing sheets of a particular test material one by one. For simulation, Monte Carlo n- Particle (MCNP) code version 4c was used and the geometry of the whole experimental setup was plotted in it. The results were then compared for each test material and it was found that lead is the best shielding material for gamma radiation followed by copper and aluminium.


Sign in / Sign up

Export Citation Format

Share Document