On intermittent flow characteristics of gas–liquid two-phase flow

2016 ◽  
Vol 310 ◽  
pp. 363-377 ◽  
Author(s):  
Jignesh Thaker ◽  
Jyotirmay Banerjee
2009 ◽  
Vol 131 (4) ◽  
Author(s):  
M. Kawaji ◽  
K. Mori ◽  
D. Bolintineanu

The effects of gas-liquid inlet geometry and mixing method on adiabatic gas-liquid two-phase flow in a microchannel of 100 μm diameter have been investigated using a T-junction inlet with the same internal diameter as the microchannel. Two-phase flow patterns, void fraction, and friction pressure drop data obtained with the T-junction inlet were found to be significantly different from those obtained previously with a reducer inlet. For the T-junction inlet, the two-phase flow patterns in the microchannel were predominantly intermittent flows with short gas and liquid plugs/slugs flowing with nearly equal velocities. The void fraction data then conformed nearly to that of a homogeneous flow model, and the two-phase friction multiplier data could be described by the Lockhart–Martinelli correlation applicable to larger channels. However, when a reducer inlet was used previously and the diameter of the inlet section was much larger than that of the microchannel, an intermittent flow of long gas slugs separated by long liquid slugs became prevalent and the void fraction decreased to values far below the homogeneous void fraction. The differences in the two-phase flow characteristics between a T-junction inlet and reducer inlet were attributed to the differences in the gas bubble/slug generation mechanisms.


Equipment ◽  
2006 ◽  
Author(s):  
Marijus Seporaitis ◽  
S. Gasiunas ◽  
Raimondas Pabarcius

2021 ◽  
pp. 103813
Author(s):  
Dewei Wang ◽  
Shanbin Shi ◽  
Yucheng Fu ◽  
Kyle Song ◽  
Xiaodong Sun ◽  
...  

Data in Brief ◽  
2018 ◽  
Vol 16 ◽  
pp. 527-530 ◽  
Author(s):  
Abdalellah O. Mohmmed ◽  
Mohammad S. Nasif ◽  
Hussain H. Al-Kayiem

Author(s):  
Jorge Pinho ◽  
Patrick Rambaud ◽  
Saïd Chabane

The goal of this study is to understand the behavior of a safety relief valve in presence of a two-phase flow induced by cavitation, in which the mass flux tends to be reduced. Two distinct safety relief valves are tested: an API 2J3 type and a transparent model based on an API 1 1/2G3 type. Instead of using a spring, the design of both valves allows the adjustment of the disk at any desired lift. Tests are conducted with water at ambient temperature. Results show a similar influence of cavitation on the flow characteristics of both valves. The liquid pressure recovery factor FL, which is normally used to identify a choked flow condition in a control valve, is experimentally determined in a safety relief valve. The existence of a local minimum located at a height position L/D = 0.14 indicates in this position, a change on the flow characteristics of both valves. It is verified that the existence of a local minimum in the liquid recovery factor is related to the minimum cross section of the flow, which does not remain constant for every lift positions. Furthermore, it is remarked that in the case of the 2J3 safety valve, the blow down ring adjustment has significant influence on the location of the minimum cross sections of the flow.


2014 ◽  
Vol 28 (2) ◽  
pp. 153-160
Author(s):  
Kenichi KATONO ◽  
Goro AOYAMA ◽  
Takuji NAGAYOSHI ◽  
Kenichi YASUDA ◽  
Koji NISHIDA

Sign in / Sign up

Export Citation Format

Share Document