Multi-slice coded coherent diffraction imaging

2022 ◽  
Vol 151 ◽  
pp. 106929
Author(s):  
Meng Li ◽  
Liheng Bian ◽  
Jun Zhang
Nano Letters ◽  
2021 ◽  
Author(s):  
Tomoya Kawaguchi ◽  
Vladimir Komanicky ◽  
Vitalii Latyshev ◽  
Wonsuk Cha ◽  
Evan R. Maxey ◽  
...  

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Rujia Li ◽  
Liangcai Cao

AbstractPhase retrieval seeks to reconstruct the phase from the measured intensity, which is an ill-posed problem. A phase retrieval problem can be solved with physical constraints by modulating the investigated complex wavefront. Orbital angular momentum has been recently employed as a type of reliable modulation. The topological charge l is robust during propagation when there is atmospheric turbulence. In this work, topological modulation is used to solve the phase retrieval problem. Topological modulation offers an effective dynamic range of intensity constraints for reconstruction. The maximum intensity value of the spectrum is reduced by a factor of 173 under topological modulation when l is 50. The phase is iteratively reconstructed without a priori knowledge. The stagnation problem during the iteration can be avoided using multiple topological modulations.


2021 ◽  
Vol 103 (21) ◽  
Author(s):  
Matthew J. Wilkin ◽  
Siddharth Maddali ◽  
Stephan O. Hruszkewycz ◽  
Anastasios Pateras ◽  
Richard L. Sandberg ◽  
...  

2021 ◽  
Vol 140 ◽  
pp. 106530
Author(s):  
Yuanyuan Liu ◽  
Qingwen Liu ◽  
You Li ◽  
Junyong Zhang ◽  
Zuyuan He

2011 ◽  
Author(s):  
Jonathan Potier ◽  
Sebastien Fricker ◽  
Mourad Idir

2018 ◽  
Vol 2 (8) ◽  
Author(s):  
S. O. Hruszkewycz ◽  
S. Maddali ◽  
C. P. Anderson ◽  
W. Cha ◽  
K. C. Miao ◽  
...  

2012 ◽  
Vol 46 (1) ◽  
pp. 234-241 ◽  
Author(s):  
Chae Un Kim ◽  
Jennifer L. Wierman ◽  
Richard Gillilan ◽  
Enju Lima ◽  
Sol M. Gruner

High-pressure cryocooling has been developed as an alternative method for cryopreservation of macromolecular crystals and successfully applied for various technical and scientific studies. The method requires the preservation of crystal hydration as the crystal is pressurized with dry helium gas. Previously, crystal hydration was maintained either by coating crystals with a mineral oil or by enclosing crystals in a capillary which was filled with crystallization mother liquor. These methods are not well suited to weakly diffracting crystals because of the relatively high background scattering from the hydrating materials. Here, an alternative method of crystal hydration, called capillary shielding, is described. The specimen is kept hydratedviavapor diffusion in a shielding capillary while it is being pressure cryocooled. After cryocooling, the shielding capillary is removed to reduce background X-ray scattering. It is shown that, compared to previous crystal-hydration methods, the new hydration method produces superior crystal diffraction with little sign of crystal damage. Using the new method, a weakly diffracting protein crystal may be properly pressure cryocooled with little or no addition of external cryoprotectants, and significantly reduced background scattering can be observed from the resulting sample. Beyond the applications for macromolecular crystallography, it is shown that the method has great potential for the preparation of noncrystalline hydrated biological samples for coherent diffraction imaging with future X-ray sources.


2018 ◽  
Vol 20 (11) ◽  
pp. 113026 ◽  
Author(s):  
Ana Katrina C Estandarte ◽  
Christopher Michael Lynch ◽  
Marianne Monteforte ◽  
Jonathan Rawle ◽  
Chris Nicklin ◽  
...  

Author(s):  
M. Zürch ◽  
A. Guggenmos ◽  
R. Jung ◽  
J. Rothhardt ◽  
C. Späth ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document