Lumen-apposing metal stents versus double-pigtail plastic stents in the endoscopic step-up approach for infected necrotizing pancreatitis

Pancreatology ◽  
2021 ◽  
Vol 21 ◽  
pp. S39-S40
Author(s):  
L. Boxhoorn ◽  
R.C. Verdonk ◽  
M.G. Besselink ◽  
W. Curvers ◽  
S.M. van Dijk ◽  
...  
2021 ◽  
Vol 93 (6) ◽  
pp. AB244
Author(s):  
Lotte Boxhoorn ◽  
Robert C. Verdonk ◽  
Marc G. Besselink ◽  
Marja A. Boermeester ◽  
Thomas Bollen ◽  
...  

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Sang Hoon Lee ◽  
Yeon Suk Kim ◽  
Eui Joo Kim ◽  
Hee Seung Lee ◽  
Jeong Youp Park ◽  
...  

AbstractChronic pancreatitis (CP) related main pancreatic duct (MPD) stricture has been a challenge for endoscopists. Fully covered self-expandable metal stents (FC-SEMS) has been tried in CP patients, but the efficacy and safety are still controversial. Thus, we aim to compare the long-term clinical efficacy of FC-SEMS vs. plastic stent placement in persistent MPD strictures secondary to CP. Between 2007 and 2018, 80 chronic pancreatitis patients (58 males, median age 49 years), who underwent endoscopic placement of FC-SEMS (n = 26) and plastic stent (n = 54) for persistent MPD strictures after at least 3 months of initial single plastic stenting, were retrospectively analyzed during a median follow-up duration of 33.7 months. As a result, MPD stricture resolution rate was statistically higher in FC-SEMS group (87.0% vs. 42.0%, p < 0.001). Although immediate complications occurred similarly (38.5% vs. 37.0%, p = 0.902), spontaneous migration (26.9%) and de novo strictures (23.1%) were pronounced delayed complications in FC-SEMS group. Pain relief during follow-up was significantly higher in FC-SEMS group (76.9% vs. 53.7%, p = 0.046). The total procedure cost was similar in both groups ($1,455.6 vs. $1,596.9, p = 0.486). In comparison with plastic stent, FC-SEMS placement for persistent MPD strictures had favorable long-term clinical efficacy, with its typical complications like spontaneous migration and de novo strictures.


2021 ◽  
Vol 09 (06) ◽  
pp. E888-E894
Author(s):  
Nichol S. Martinez ◽  
Sumant Inamdar ◽  
Sheila N. Firoozan ◽  
Stephanie Izard ◽  
Calvin Lee ◽  
...  

Abstract Background and study aims There are conflicting data regarding the risk of post-ERCP pancreatitis (PEP) with self-expandable metallic stents (SEMS) compared to polyethylene stents (PS) in malignant biliary obstructions and limited data related to benign obstructions. Patients and methods A retrospective cohort study was performed of 1136 patients who underwent ERCP for biliary obstruction and received SEMS or PS at a tertiary-care medical center between January 2011 and October 2016. We evaluated the association between stent type (SEMS vs PS) and PEP in malignant and benign biliary obstructions. Results Among the 1136 patients included in our study, 399 had SEMS placed and 737 had PS placed. Patients with PS were more likely to have pancreatic duct cannulation, pancreatic duct stent placement, double guidewire technique, sphincterotomy and sphincteroplasty as compared to the SEMS group. On multivariate analysis, PEP rates were higher in the SEMS group (8.0 %) versus the PS group (4.8 %) (OR 2.27 [CI, 1.22, 4.24]) for all obstructions. For malignant obstructions, PEP rates were 7.8 % and 6.6 % for SEMS and plastic stents, respectively (OR 1.54 [CI, 0.72, 3.30]). For benign obstructions the PEP rate was higher in the SEMS group (8.8 %) compared to the PS group (4.2 %) (OR 3.67 [CI, 1.50, 8.97]). No significant differences between PEP severity were identified based on stent type when stratified based on benign and malignant. Conclusions PEP rates were higher when SEMS were used for benign obstruction as compared to PS. For malignant obstruction, no difference was identified in PEP rates with use of SEMS vs PS.


2014 ◽  
Vol 51 (3) ◽  
pp. 240-249 ◽  
Author(s):  
Lucas Souto NACIF ◽  
Wanderley Marques BERNARDO ◽  
Luca BERNARDO ◽  
Wellington ANDRAUS ◽  
Lucas TORRES ◽  
...  

Context Biliary strictures after liver transplantation are recognized as its Achilles’ heel. The strictures are classified in anastomotic and ischemic or non-anastomotic biliary strictures, and they figure among the most common complications after liver transplantation. There are some treatment options including balloon dilation, the placement of multiple plastic stents and the placement of self-expandable metal stents and all of them seem to have good results. Objectives The aim of this study was to systematically review the literature concerning the results of the endoscopic treatment of anastomotic biliary strictures after liver transplantation. Methods A systematic review of the literature was performed on the management of anastomotic biliary strictures post- orthotopic liver transplantation. The Medline-PubMed, EMBASE, Scielo-LILACS, and Cochrane Databases were electronically searched from January 1966 to April 2013. Results No well-designed randomized controlled trial was found. Most studies were retrospective or prospective comparisons in design. One study (86 patients) compared the endoscopic and the percutaneous accesses. The sustained clinical success rates were similar but the treatment duration was longer in the percutaneous group access. Two studies (56 patients) compared balloon dilation with balloon dilation and multiple plastic stents. There were no differences concerning sustained clinical success and complication rates. Conclusions Balloon dilation is as effective as balloon dilation plus multiple plastic stenting for the resolution of the anastomotic biliary strictures. Well-designed randomized trials are still needed to compare balloon dilation versus multiple plastic stenting versus metallic stenting.


2018 ◽  
Vol 33 (5) ◽  
pp. 1412-1425 ◽  
Author(s):  
Rebecca Saunders ◽  
Jayapal Ramesh ◽  
Silvia Cicconi ◽  
Jonathan Evans ◽  
Vincent S. Yip ◽  
...  

Endoscopy ◽  
2020 ◽  
Vol 52 (06) ◽  
pp. 474-482
Author(s):  
Pierre H. Deprez ◽  
Tom G. Moreels ◽  
Tarik Aouattah ◽  
Hubert Piessevaux ◽  
Enrique Pérez-Cuadrado-Robles

Background Self-expanding metal stents (SEMSs) are recommended in unresectable distal malignant biliary obstruction. However, problems with dysfunction and migration of these stents are not negligible. We aimed to investigate the effectiveness and safety of a new 12-Fr plastic stent. Methods In an observational, prospective study, all consecutive patients who underwent biliary stenting with the 12-Fr stent were considered (index group). Referent groups were a historical cohort, matched by sex, etiology, and metastatic status, including patients with 10-Fr plastic stents and with fully covered and uncovered SEMSs (FCSEMSs and UCSEMSs). Outcomes were stent patency, recurrent biliary obstruction (RBO), technical success, 30-day mortality and adverse events. A post-procedure examination of removed stents was done. Results 72 patients (median age 66, range 32 – 94 years, 50 % men) were included (24 index, 48 referents). There were no differences in median stent patency time (P = 0.684). RBO was significantly lower with the 12-Fr compared with the 10-Fr profile stent (50 % vs. 81.3 %, P = 0.04), but no difference was found compared with the FCSEMSs (50 % vs. 43.8 %, P = 0.698). Technical success was 100 %, with no differences in 30-day mortality P = 0.105). The adverse events rate was 4.2 % for both groups (index n = 1, referents n = 2). Of 11 removed 12-Fr plastic stents suspected to be dysfunctional, 7 (64 %) were still patent. Conclusions This new 12-Fr plastic stent could be an effective and cheaper alternative to SEMSs in distal malignant biliary obstruction.


Sign in / Sign up

Export Citation Format

Share Document