scholarly journals Effect of Increasing Ductility Factors on the Performance of a Steel Moment Resisting Frame Designed by the Performance Based Plastic Design Method attuned with Indian Code of Practice

2017 ◽  
Vol 173 ◽  
pp. 1862-1869 ◽  
Author(s):  
Sejal P. Dalal ◽  
Purvang D. Dalal ◽  
Atul K. Desai
2021 ◽  
Vol 10 (12) ◽  
pp. 174-179
Author(s):  
Özlem Çavdar

In earthquake engineering, a performance-based design method is used to determine the level of the expected performance of the structures under the earthquake effect. The level of performance is related to the damage situation that could be occurred in the structure after the earthquake. In the performance-based structural design, it is predicted that more than one damage levels emerge under one certain earthquake effect. In this study, the seismic behavior of steel structures with plan irregularities in the Turkey Building Earthquake Code in the 2018 (TBEC-2018) is investigated by the nonlinear static analysis methods. The selected steel structures are located in İzmir, Turkey. The Turkey Earthquake Code in 2018 is considered for assessing seismic performance evaluation of the selected moment-resisting frame steel building. Four different A3 type irregularity was investigated. The steel building with no irregularity in its plan. was selected as the structure of the reference. The performance goals of the five different steel structures are evaluated by applying the pushover and procedures of the TBEC-2018. The steel structures were compared by obtaining pushover curves for both the X and Y directions. The results show that the effects of A3 type irregularity should be not considered in design and buildings without irregularities are safer.


1999 ◽  
Vol 26 (1) ◽  
pp. 35-54 ◽  
Author(s):  
Aiman Biddah ◽  
Arthur C Heidebrecht

Steel moment resisting frames have been considered as excellent systems for resisting seismic loads. However, after recent earthquakes (e.g., Northridge, California, in 1994 and Kobe, Japan, in 1995) the confidence in this structural system was reduced as a result of various types of damage that moment resisting steel frames suffered. This paper presents the results of the evaluation of seismic level of protection afforded to steel moment resisting frame buildings designed in accordance with the National Building Code of Canada. Six- and 10-storey office buildings located in a region of intermediate seismic hazard are designed in accordance with the current Canadian code provisions. Three different design philosophies are considered, namely strong column - weak beam (SCWB), weak column - strong beam (WCSB), and strong column - weak panel zone (SCWP). The performance of these frames is evaluated dynamically by subjecting an inelastic model to an ensemble of 12 actual strong ground motion records. The model takes into account both connection flexibility and panel zone shear deformation. The results are presented in terms of response parameters determined from static pushover analyses, as well as statistical measures of the maximum response parameters determined from the inelastic dynamic analyses. The computed performance of the frames is evaluated in order to assess both the overall level of protection of the frames and the preferred design philosophy. It is concluded that a well-designed and well-detailed ductile moment resisting frame designed using either the SCWB or SCWP design philosophy can withstand ground motions of twice the design level with very little likelihood of collapse, whereas a frame designed using the WCSB approach is ill-conditioned and may develop a collapse mechanism at an excitation level well below twice the design level.Key words: seismic, ductile, steel, frame buildings, performance, design, ductility, damage, inelastic, dynamic.


Sign in / Sign up

Export Citation Format

Share Document