Microleakage of thin-walled monolithic zirconia and polymer-containing CAD-CAM crowns

Author(s):  
Maximiliane A. Schlenz ◽  
Carsten Fiege ◽  
Alexander Schmidt ◽  
Bernd Wöstmann
2020 ◽  
Vol 75 (9) ◽  
pp. 505-510
Author(s):  
Veerasamy Yengopal

1. Prosthetic outcomes and clinical performance of CAD-CAM monolithic zirconia versus porcelain-fused-to-metal implant crowns in the molar region - 2. The effect of using a mobile application to improve oral hygiene among adolescents receiving fixed orthodontic treatment: A RCT


2016 ◽  
Vol 116 (6) ◽  
pp. 890-895 ◽  
Author(s):  
Ediz Kale ◽  
Emre Seker ◽  
Burak Yilmaz ◽  
Tuncer Burak Özcelik

2017 ◽  
Vol 118 (6) ◽  
pp. 736-741 ◽  
Author(s):  
Ediz Kale ◽  
Burak Yilmaz ◽  
Emre Seker ◽  
Tuncer Burak Özcelik

2018 ◽  
Vol 44 (5) ◽  
pp. 330-334 ◽  
Author(s):  
Pauliina Moilanen ◽  
Jenni Hjerppe ◽  
Lippo V. J. Lassila ◽  
Timo O. Närhi

New monolithic zirconia materials can be used to fabricate full-contour fixed dental prostheses with the computer-aided design/computer-aided manufacturing (CAD/CAM) method. The aim of this study was to examine the fracture strength and precision of fit of screw-retained monolithic zirconia crowns made directly on implants or by cementing on prefabricated titanium (Ti) bases. Monolithic screw-retained implant crowns (n = 6) were produced by CAD/CAM method using partially (PSZ) and fully stabilized (FSZ) zirconia. Industrially produced zirconia crowns were used as a reference. A lateral incisor study model was made onto an implant replica. Crowns were produced either directly on the implant or through cementing on a prefabricated titanium base (PSZ+Ti, FSZ+Ti). The crowns were tightened to implant replicas with a torque of 35 Ncm. The gap between the replica and the abutment or crown was measured from ×400 scanning electron microscope images for precision of fit. Mechanical testing until failure was completed with a universal testing machine with loading angle of 45°. Statistical analysis was performed (analysis of variance). Mean (±SD) failure loads were 259 ± 23 (PSZ), 140 ± 13 (FSZ), 453 ± 25 (PSZ+Ti), 439 ± 41 (FSZ+Ti), and 290 ± 39 (Procera). Mean (±SD) gap values were 2.2 ± 0.2 (PSZ), 2.5 ± 1.0 (FSZ), 7.0 ± 1.0 (PSZ+Ti), 7.7 ± 1.6 (FSZ+Ti), and 6.7 ± 1.7 (Procera). Monolithic zirconia crowns with a Ti base clearly show higher fracture strengths than the crowns fixed directly on the implant surface. Better marginal fit can be achieved with direct zirconia crowns than with crowns on a titanium base or industrially produced zirconia crowns.


Author(s):  
Zahra Khamverdi1 ◽  
Elmira Najafrad ◽  
Maryam Farhadian

Objectives: Marginal and internal fit of restorations are two important clinical factors for assessing the quality and durability of computer-aided design/computer-aided manufacturing (CAD/CAM)-fabricated monolithic zirconia restorations. The purpose of this study was to evaluate the marginal and internal fit of CAD/CAM zirconia crowns with two different scanners (i3D scanner and 3Shape D700). Materials and Methods: Twelve extracted sound human posterior teeth were prepared for full zirconia crowns. Two different extraoral scanners namely i3D scanner and 3Shape D700 were used to digitize type IV gypsum casts poured from impressions. The crowns were milled from presintered monolithic zirconia blocks by a 5-axis milling machine. The replica technique and MIP4 microscopic image analysis software were utilized to measure the marginal and internal fit by a stereomicroscope at ×40 magnification. The collected data were analyzed by paired t-test. Results: The mean marginal gap was 203.62 μm with 3Shape D700 scanner and 241.07 μm with i3D scanner. The mean internal gap was 192.30 μm with 3Shape D700 scanner and 196.06 μm with i3D scanner. The results of paired t-test indicated that there was a statistically significant difference between the two scanners in marginal fit (P=0.04); while, there was no statistically significant difference in internal fit (P=0.761). Conclusion: Within the limitations of this study, the results showed that type of extraoral scanner affected the marginal fit of CAD/CAM fabricated crowns; however, it did not have a significant effect on their internal fit.


2019 ◽  
pp. 0000-0000
Author(s):  
Enkhjargal Bayarsaikhan ◽  
Sangho Eom ◽  
Ui-Won Jung ◽  
Jae Hoon Lee

A 62-year-old male patient sought treatment for missing maxillary teeth. A diagnostic cast demonstrated that the interocclusal distance was insufficient. A five-unit screw-retained implant-supported fixed partial denture (FPD) was used to restore missing maxillary teeth. The restoration of multiple missing teeth using an implant-supported FPD is challenging when the interocclusal distance is limited due to lack of retention and inadequate esthetics. In this case, a hexagonal, screw-retained, and sublingually located titanium-based zirconia implant-supported FPD with a conical abutment base was used for restoration to overcome the limited interocclusal distance. This implant-supported FPD, consisting of CAD/CAM-designed monolithic zirconia cemented to a titanium bonding base in the laboratory, is expected to facilitate predictable retention and adequate esthetics as well as provide ease of retrieval.


2014 ◽  
Vol 2014 ◽  
pp. 1-7 ◽  
Author(s):  
Davide Augusti ◽  
Gabriele Augusti ◽  
Andrea Borgonovo ◽  
Massimo Amato ◽  
Dino Re

Different indirect restorations to replace a single missing tooth in the posterior region are available in dentistry: traditional full-coverage fixed dental prostheses (FDPs), implant-supported crowns (ISC), and inlay-retained FDPs (IRFDP). Resin bonded FDPs represent a minimally invasive procedure; preexisting fillings can minimize tooth structure removal and give retention to the IRFDP, transforming it into an ultraconservative option. New high strength zirconia ceramics, with their stiffness and high mechanical properties, could be considered a right choice for an IRFDP rehabilitation. The case report presented describes an IRFDP treatment using a CAD/CAM monolithic zirconia IRFDP; clinical and laboratory steps are illustrated, according to the most recent scientific protocols. Adhesive procedures are focused on the Y-TZP and tooth substrate conditioning methods. Nice esthetic and functional integration of indirect restoration at two-year follow-up confirmed the success of this conservative approach.


Sign in / Sign up

Export Citation Format

Share Document