Patient-specific organ dose estimation during transcatheter arterial embolization using Monte Carlo method and adaptive organ segmentation

2014 ◽  
Vol 104 ◽  
pp. 376-380 ◽  
Author(s):  
Hui-Yu Tsai ◽  
Yung-Chieh Lin ◽  
Yeu-Sheng Tyan
Author(s):  
Wanyi Fu ◽  
William P. Segars ◽  
Ehsan Abadi ◽  
Shobhit Sharma ◽  
Anuj J. Kapadia ◽  
...  

2020 ◽  
Author(s):  
Ying Huang ◽  
Yang Yang ◽  
Xin Chen ◽  
Yiming Gao ◽  
Weihai Zhuo ◽  
...  

BACKGROUND CT imaging is one of the most important contributors to medical radiation exposure(1). The frequency of CT scans and radiation doses accepted by patients attracted serious concerns for health physics researchers. The utilization of advanced technology ATCM has the potentials to reduce CT radiation doses while diagnostic image quality is maintained (2-7). As ATCM adjusted tube currents slice by slice it brought challenges to organ dose estimation using conversion factors derived from fixed tube current. Cross-system communication with hospital Picture Archive and Communication System (PACS),made it possible to read massive data automatically like the scanning parameters of each slice in each case. Monte Carlo simulations are probably the most reliable techniques which could be used for accurate dose assessment. [8-11]. However, specific patient model development and specific patient dose simulations are computationally demanding and may require dedicated hardware resources, this limitation constrained its application in large scale investigation. As an alternative method, patient specific organ doses could be calculated using the patient specific scan parameters and the Monte Carlo simulated organ doses with reference human phantom, and then correct the results with patient size factors. Dw is referred as the preferred patient size metric that determined the patient group and affected organ dose. The distance of the pathway traversed by the X-ray beam could provide the best approximation of tissue length traversed during the examination (12, 13),as CT image is a cross-sectional map normalized to the linear attenuation of water (14). The purpose of current study was to establish a method to access patient-specific organ dose associated with ATCM in chest computed tomography (CT) scans by combining Monte Carlo simulation with parameters contracted from clinical CT images of each patient underwent chest CT scan with ATCM. OBJECTIVE To explore a method to access patient-specific organ dose associated with automatic tube current modulation (ATCM) in chest computed tomography (CT) scans based on the information extracted from PACS automatically. METHODS 176cases of chest CT scans were read through cross-system communication with hospital PACS. A total of 8468 images were collected and analyzed automatically using in-house software. The scanning parameters (kVp, tube current, collimation width, etc.) of each CT examination were collected in real time, and a middle CT image of each case was collected for patient size(water equivalent diameter, Dw) calculation. Based on the reference human phantom, organ doses were simulated slice by slice using Monte Carlo method. The patient specific organ doses were calculated by combining tube currents of each patient slice with the simulated results, and doses were revised by correction factors that related to patient size. RESULTS A sum of 8468 slice of tube currents were extracted and analyzed in this study, the average mAs for large size patient group was about 1.6 times to the small size patient group. For organs that covered in the scan range like lung, breast, heart, the dose values were 18.30±2.91mGy, 15.13 ±2.75mGy and 17.87±2.96mGy in small size patients(Dw smaller than 22cm).The dose values of lung, breast, heart, in medium-sized patients (Dw from 22cm to 25cm) were 21.89±4.60mGy, 18.16 ±4.13mGy and 21.46±4.60mGy, while the values were 24.98±4.40mGy, 20.81±3.66mGy and 24.77±4.46mGy respectively in large size patients(Dw larger than 25cm). The organ doses increase with the patient size due to the increase of mAs. CONCLUSIONS The PACS-based method of large batch organ dose calculation to patients undergoing chest CT with ATCM was established. The methods and results may provide guidance to the design and optimization of chest CT protocols with ATCM.


2020 ◽  
Vol 6 (4) ◽  
pp. 045016
Author(s):  
Choonsik Lee ◽  
Jiamin Liu ◽  
Keith Griffin ◽  
Les Folio ◽  
Ronald M Summers

2021 ◽  
Vol 60 (1) ◽  
pp. 93-113
Author(s):  
Nina Petoussi-Henss ◽  
Daiki Satoh ◽  
Helmut Schlattl ◽  
Maria Zankl ◽  
Vladimir Spielmann

AbstractThis article presents nuclide-specific organ dose rate coefficients for environmental external exposures due to soil contamination assumed as a planar source at a depth of 0.5 g cm−2 in the soil and submersion to contaminated air, for a pregnant female and its fetus at the 24th week of gestation. Furthermore, air kerma free-in-air coefficient rates are listed. The coefficients relate the organ equivalent dose rates (Sv s−1) to the activity concentration of environmental sources, in Bq m−2 or Bq m−3, allowing to time-integrate over a particular exposure period. The environmental radiation fields were simulated with the Monte Carlo radiation transport codes PHITS and YURI. Monoenergetic organ dose rate coefficients were calculated employing the Monte Carlo code EGSnrc simulating the photon transport in the voxel phantom of a pregnant female and fetus. Photons of initial energies of 0.015–10 MeV were considered including bremsstrahlung. By folding the monoenergetic dose coefficients with the nuclide decay data, nuclide-specific organ doses were obtained. The results of this work can be employed for estimating the doses from external exposures to pregnant women and their fetus, until more precise data are available which include coefficients obtained for phantoms at different stages of pregnancy.