Highly sensitive determination of diclofenac based on resin beads and a novel polyclonal antibody by using flow injection chemiluminescence competitive immunoassay

Author(s):  
Jing Shi ◽  
Mingxia Xu ◽  
Qinghui Tang ◽  
Kang Zhao ◽  
Anping Deng ◽  
...  
The Analyst ◽  
2015 ◽  
Vol 140 (18) ◽  
pp. 6373-6378 ◽  
Author(s):  
Mingxia Xu ◽  
Mengting Chen ◽  
Tiantian Dong ◽  
Kang Zhao ◽  
Anping Deng ◽  
...  

A convenient competitive immunoassay of Hg2+ using carboxylic resin beads, specific monoclonal antibody and enzymatic amplification is proposed with flow injection chemiluminescence detection.


Luminescence ◽  
2006 ◽  
Vol 21 (1) ◽  
pp. 43-48 ◽  
Author(s):  
Qian Li ◽  
Chengzhi Huang ◽  
Yuming Huang

2006 ◽  
Vol 60 (4) ◽  
Author(s):  
X. Xie ◽  
X. Shao ◽  
Z. Song

AbstractA simple flow-injection chemiluminescence method with synergistic enhancement has been investigated for the rapid and sensitive determination of antipsychotic risperidone. The synergistic action was significant in the chemiluminescence system of luminol—hydrogen peroxide with risperidone as an enhancer. The increased chemiluminescence intensity was correlated with risperidone concentration within the range from 10 pg mL−1 to 1.0 ng mL−1 with relative standard deviations lower than 5.0 % and the detection limit of 4 pg mL−1. At a flow rate of 2.0 mL min−1, the flow-injection chemiluminescence method exhibited both a high sensitivity and excellent selectivity giving a throughput of 120 times per hour. The proposed method was successfully applied to determine the risperidone content in human urine without any pretreatment. It was found that the excretive amounts of risperidone reached their maximum after taking 2.0 mg of risperidone for 1 h, with a total excretive ratio of 17.37 % in 8.5 h.


2000 ◽  
Vol 83 (6) ◽  
pp. 1299-1305 ◽  
Author(s):  
Fatma A Aly ◽  
Salma A Al-Tamimi ◽  
Abdulrahman A Alwarthan

Abstract A rapid and highly sensitive flow-injection chemiluminometric method was developed for determination of 3 sympathomimetic drugs, namely, etilefrine hydrochloride, isoxsuprine hydrochloride, and prenalterol hydrochloride. The method is based on chemiluminescence induced by oxidation of drugs with acidified potassium permanganate in the presence of formic acid as a carrier. The calibration graphs were linear over the concentration ranges 0.2–9, 0.2–12.5, and 0.025–1.25 μg/mL for the 3 compounds, respectively. The method was applied successfully in determining the drugs in dosage forms and in biological fluids. A proposal for the reaction pathway is suggested.


Sign in / Sign up

Export Citation Format

Share Document