Earthquake response of a three-span bridge, with mid-span supported by isolators, to near-field pulse and permanent-displacement step

2013 ◽  
Vol 48 ◽  
pp. 89-103
Author(s):  
Reza S. Jalali ◽  
Masoumeh Bahari Jokandan ◽  
Mihailo D Trifunac
2004 ◽  
Vol 20 (3) ◽  
pp. 597-615 ◽  
Author(s):  
W. L. Ellsworth ◽  
M. Celebi ◽  
J. R. Evans ◽  
E. G. Jensen ◽  
R. Kayen ◽  
...  

A free-field recording of the Denali fault earthquake was obtained by the Alyeska Pipeline Service Company 3 km from the surface rupture of the Denali fault. The instrument, part of the monitoring and control system for the trans-Alaska pipeline, was located at Pump Station 10, approximately 85 km east of the epicenter. After correction for the measured instrument response, we recover a seismogram that includes a permanent displacement of 3.0 m. The recorded ground motion has relatively low peak acceleration (0.36 g) and very high peak velocity (180 cm/s). Nonlinear soil response may have reduced the peak acceleration to this 0.36 g value. Accelerations in excess of 0.1 g lasted for 10 s, with the most intense motion occurring during a 1.5-s interval when the rupture passed the site. The low acceleration and high velocity observed near the fault in this earthquake agree with observations from other recent large-magnitude earthquakes.


2015 ◽  
Vol 2015 ◽  
pp. 1-17 ◽  
Author(s):  
Guiyun Yan ◽  
Fuquan Chen

Excessive deformation of the isolation layer in midstory isolated structures may occur under strong near-field pulse-like ground motion, which would result in the overturning collapse of the superstructure. The objective of the present research is to limit excessive deformation of the isolation layer and to reduce nonlinear response of midstory isolated structures. To this end, a protective system is presented to limit deformation of the isolation layer by soft pounding. Based on the Kelvin pounding model, a mechanical model is put forward for this protective system. In addition, a new method has been proposed that synthesizes artificial near-field pulse-like ground motion by combining the real near-field nonpulse ground motion with simple equivalent pulses. Also, the impact of artificial near-field pulse-like ground motion on the nonlinear response of midstory isolated structures and the deformation of the isolation layer has been investigated. The effectiveness of the midstory isolation with the protective system has been validated. The results show that the maximum deformation of the isolation layer significantly exceeds the allowable deformation of lead-rubber bearings when subjected to near-field pulse-like ground motion, and it causes the lead-rubber bearings destruction. The proposed protective system is effective in restricting the excessive deformation of the isolation layer and reducing nonlinear responses of the isolated structure, preventing collapse of the superstructure.


Sign in / Sign up

Export Citation Format

Share Document