Characteristics of particulate matter (PM) concentrations influenced by piston wind and train door opening in the Shanghai subway system

Author(s):  
Jiajia Wang ◽  
Laijun Zhao ◽  
Daoli Zhu ◽  
H. Oliver Gao ◽  
Yujing Xie ◽  
...  
2017 ◽  
Vol 10 (8) ◽  
pp. 1015-1028 ◽  
Author(s):  
Eleni Mammi-Galani ◽  
Konstantinos Eleftheriadis ◽  
Luis Mendes ◽  
Mihalis Lazaridis

2020 ◽  
Vol 30 (Supplement_5) ◽  
Author(s):  
A Della Camera ◽  
G Spataro ◽  
G Cevenini ◽  
N Nante ◽  
F M De Marco ◽  
...  

Abstract Background The operating theatres (OTs) have adequate conditions to perform safe operations and to prevent surgical site infections. Opening doors can compromise these situations. Measurement of particulate contamination is a key point to check the effectiveness of preventive measures in the OTs. We analysed how openings impact in different type of OTs. Methods Between January/February 2020 a transversal study was conducted in 5 different types of OTs in a university hospital. Two had laminar flows, with 55 and 60 air changes/h; three had turbulent flows: OT-A (18 air changes/h, with 4 inlets from the ceiling), OT-B (23 air changes/h and air flow from the ceiling plenum), OT-C (16 air changes/h, air flow directed from one wall to the opposite wall and the main door laterally to the flow). Particulate matter (PM) measurements were carried out in 7 different points in each OT, alternating two conditions: a) doors closed; b) opening/closing the main door twice per minute. For each spot, in each condition, we recorded for several minutes the following parameters: particles (0.3, 0.5, 1, 3, 5, 10µ), room temperature (Ta), Relative Humidity (Rh), airspeed (Va). Comparison with the Wilcoxon test were made using STATA 14. Results In laminar flow, classified with better ISO levels (4), opening and closing the door the PM, for any size, increased not significantly (p > 0.05). The OTs with turbulent flows (ISO 5-6) had a higher particulate level than the laminar ones and greater variations with door openings. OT-A worsened significantly for all particles (p < 0.05) closing/opening the door. In contrast, OT-B and OT-C had a significant reduction of PM (p < 0.05). All 5 OTs had pressure falling to 0 at door opening; Ta, Rh and Va may be affected by different type air flows and design. Conclusions OTs parameters during door openings are influenced by different ventilation systems and room design. Laminar flows OTs are less affected, but innovative turbulent flows OTs can be just as effective. Key messages The operating rooms are affected by the door opening. Laminar flows operating rooms are less influenced by door openings than turbulent flows ones. Turbulent flow rooms have different performance depending on their construction characteristics.


2015 ◽  
Vol 511 ◽  
pp. 711-722 ◽  
Author(s):  
Vânia Martins ◽  
Teresa Moreno ◽  
María Cruz Minguillón ◽  
Fulvio Amato ◽  
Eladio de Miguel ◽  
...  

2021 ◽  
pp. 111620
Author(s):  
Jianlin Ren ◽  
Junjie He ◽  
Xiangfei Kong ◽  
Wei Xu ◽  
Yiting Kang ◽  
...  

2008 ◽  
Vol 105 (12) ◽  
pp. 586-595
Author(s):  
M. Dormann ◽  
B. Vanderheyden ◽  
D. Steyls

1972 ◽  
Vol 27 (02) ◽  
pp. 263-271 ◽  
Author(s):  
I. A. Cooper ◽  
P Cochrane ◽  
B. G. Firkin ◽  
K. J. Pinkard

SummaryIt has been suggested that human platelets possess the ability to phagocytose particulate matter similar to the polymorphonuclear leukocyte. However some difference of opinion has arisen regarding this contention, particularly as differences have been demonstrated with regard to the observed metabolic changes occurring in platelets related to such a process.The experiments reported in this paper were designed to observe the aerobic and anaerobic metabolism in human platelets during and following interiorization of two different particles, viz. polystyrene latex and thorotrast. The results of these experiments show a marked difference between both types of particles with regard to observable metabolic changes despite the rapid interiorization of both types of material. Some alteration occurs in both aerobic and anaerobic metabolism a considerable time after interiorization of latex, whereas no alteration could be demonstrated after interiorization of thorotrast. It is suggested that the interiorization of particulate matter is by some process other than phagocytosis and that observed metabolic changes related to latex may be due to a release reaction.


Sign in / Sign up

Export Citation Format

Share Document