Design resistance of longitudinal gusset-tube K-joints with 1/4 annular plates in transmission towers

2019 ◽  
Vol 144 ◽  
pp. 106271 ◽  
Author(s):  
Fang Li ◽  
Hong-zhou Deng ◽  
Xiao-yi Hu
Sensors ◽  
2021 ◽  
Vol 21 (4) ◽  
pp. 1228
Author(s):  
Ting On Chan ◽  
Linyuan Xia ◽  
Yimin Chen ◽  
Wei Lang ◽  
Tingting Chen ◽  
...  

Ancient pagodas are usually parts of hot tourist spots in many oriental countries due to their unique historical backgrounds. They are usually polygonal structures comprised by multiple floors, which are separated by eaves. In this paper, we propose a new method to investigate both the rotational and reflectional symmetry of such polygonal pagodas through developing novel geometric models to fit to the 3D point clouds obtained from photogrammetric reconstruction. The geometric model consists of multiple polygonal pyramid/prism models but has a common central axis. The method was verified by four datasets collected by an unmanned aerial vehicle (UAV) and a hand-held digital camera. The results indicate that the models fit accurately to the pagodas’ point clouds. The symmetry was realized by rotating and reflecting the pagodas’ point clouds after a complete leveling of the point cloud was achieved using the estimated central axes. The results show that there are RMSEs of 5.04 cm and 5.20 cm deviated from the perfect (theoretical) rotational and reflectional symmetries, respectively. This concludes that the examined pagodas are highly symmetric, both rotationally and reflectionally. The concept presented in the paper not only work for polygonal pagodas, but it can also be readily transformed and implemented for other applications for other pagoda-like objects such as transmission towers.


2021 ◽  
Vol 11 (12) ◽  
pp. 5623
Author(s):  
Nur Alia Farina Mohd Nasir ◽  
Mohd Zainal Abidin Ab Kadir ◽  
Miszaina Osman ◽  
Muhamad Safwan Abd Rahman ◽  
Ungku Anisa Ungku Amirulddin ◽  
...  

This paper presents a comparative analysis of different earthing designs’ performances, with particular interest on the use of earthing enhancing compound (EEC) for a selected earthing design of 500 kV transmission towers in a rocky soil, using the SESCAD tool of the Current distribution, electromagnetic field grounding and soil structure analysis (CDEGS) software. The simulation included the interpretation of soil profile and comparison between designs A, B and C, which are currently used for the 500 kV tower footing resistance (TFR) improvement. Results showed each design had reduced the TFR by 66%, 54.7% and 63.2% for the towers T42, T48 and T50, respectively. In some cases, further improvement of TFR is required, especially in the rocky area where the soil resistivity (SR) value is of more than 500 Ω⋅m. In this case, EEC was used in Design C, encasing both the vertical and horizontal electrodes, and it reduced the TFR further by 16% to 20%. The characteristics of the soil and earthing arrangement design play an important role in achieving a low TFR value, which is directly proportional to the backflashover occurrence and thus to the transmission line performance.


2004 ◽  
Vol 37 (4) ◽  
pp. 285-306 ◽  
Author(s):  
Haider N. Arafat ◽  
Ali H. Nayfeh

Sign in / Sign up

Export Citation Format

Share Document