378 Gastric Muscle Tone During Emptying Analyzed By Finite Element Simulation Using Concurrent Magnetic Resonance Imaging and Fiber Optic Pressure Measurement

2009 ◽  
Vol 136 (5) ◽  
pp. A-62
Author(s):  
Tanu Rawal ◽  
Mohammed S. Rizvi ◽  
Vikram Pagaria ◽  
Mark R. Fox ◽  
Reto Treier ◽  
...  
2017 ◽  
Vol 35 (18) ◽  
pp. 3924-3933 ◽  
Author(s):  
Massimo L. Filograno ◽  
Marco Pisco ◽  
Angelo Catalano ◽  
Ernesto Forte ◽  
Marco Aiello ◽  
...  

2014 ◽  
Vol 136 (4) ◽  
Author(s):  
Robert E. Carey ◽  
Liying Zheng ◽  
Ameet K. Aiyangar ◽  
Christopher D. Harner ◽  
Xudong Zhang

In this paper, we present a new methodology for subject-specific finite element modeling of the tibiofemoral joint based on in vivo computed tomography (CT), magnetic resonance imaging (MRI), and dynamic stereo-radiography (DSX) data. We implemented and compared two techniques to incorporate in vivo skeletal kinematics as boundary conditions: one used MRI-measured tibiofemoral kinematics in a nonweight-bearing supine position and allowed five degrees of freedom (excluding flexion-extension) at the joint in response to an axially applied force; the other used DSX-measured tibiofemoral kinematics in a weight-bearing standing position and permitted only axial translation in response to the same force. Verification and comparison of the model predictions employed data from a meniscus transplantation study subject with a meniscectomized and an intact knee. The model-predicted cartilage-cartilage contact areas were examined against “benchmarks” from a novel in situ contact area analysis (ISCAA) in which the intersection volume between nondeformed femoral and tibial cartilage was characterized to determine the contact. The results showed that the DSX-based model predicted contact areas in close alignment with the benchmarks, and outperformed the MRI-based model: the contact centroid predicted by the former was on average 85% closer to the benchmark location. The DSX-based FE model predictions also indicated that the (lateral) meniscectomy increased the contact area in the lateral compartment and increased the maximum contact pressure and maximum compressive stress in both compartments. We discuss the importance of accurate, task-specific skeletal kinematics in subject-specific FE modeling, along with the effects of simplifying assumptions and limitations.


1991 ◽  
Author(s):  
Michael R. Henning ◽  
David W. Gerdt ◽  
Thomas A. Spraggins

2019 ◽  
Vol 5 (1) ◽  
Author(s):  
Surabhi Nimbalkar ◽  
Erwin Fuhrer ◽  
Pedro Silva ◽  
Tri Nguyen ◽  
Martin Sereno ◽  
...  

AbstractThe recent introduction of glassy carbon (GC) microstructures supported on flexible polymeric substrates has motivated the adoption of GC in a variety of implantable and wearable devices. Neural probes such as electrocorticography and penetrating shanks with GC microelectrode arrays used for neural signal recording and electrical stimulation are among the first beneficiaries of this technology. With the expected proliferation of these neural probes and potential clinical adoption, the magnetic resonance imaging (MRI) compatibility of GC microstructures needs to be established to help validate this potential in clinical settings. Here, we present GC microelectrodes and microstructures—fabricated through the carbon micro-electro-mechanical systems process and supported on flexible polymeric substrates—and carry out experimental measurements of induced vibrations, eddy currents, and artifacts. Through induced vibration, induced voltage, and MRI experiments and finite element modeling, we compared the performances of these GC microelectrodes against those of conventional thin-film platinum (Pt) microelectrodes and established that GC microelectrodes demonstrate superior magnetic resonance compatibility over standard metal thin-film microelectrodes. Specifically, we demonstrated that GC microelectrodes experienced no considerable vibration deflection amplitudes and minimal induced currents, while Pt microelectrodes had significantly larger currents. We also showed that because of their low magnetic susceptibility and lower conductivity, the GC microelectrodes caused almost no susceptibility shift artifacts and no eddy-current-induced artifacts compared to Pt microelectrodes. Taken together, the experimental, theoretical, and finite element modeling establish that GC microelectrodes exhibit significant MRI compatibility, hence demonstrating clear clinical advantages over current conventional thin-film materials, further opening avenues for wider adoption of GC microelectrodes in chronic clinical applications.


Sign in / Sign up

Export Citation Format

Share Document