Sa1225 Meta-Analysis: Faecal Calprotectin for Assessment of Inflammatory Bowel Disease Activity

2014 ◽  
Vol 146 (5) ◽  
pp. S-235
Author(s):  
Jin-Feng Lin ◽  
Jin-Min Chen ◽  
Biao Nie ◽  
Bo Jiang
2020 ◽  
Vol 14 (Supplement_1) ◽  
pp. S391-S393
Author(s):  
F de Voogd ◽  
H Joshi ◽  
E Van Wassenaer ◽  
G D’Haens ◽  
K Gecse

Abstract Background Disease activity during pregnancy in women with inflammatory bowel disease (IBD) is associated with miscarriage, preterm delivery and low birth weight. Monitoring disease activity throughout the pregnancy is therefore important. Gastrointestinal ultrasound (GIUS) has a high potential as a point-of-care tool for monitoring disease activity in IBD as it has been shown to correlate well with endoscopy and magnetic resonance imaging. However, data are scarce on the use of GIUS in IBD throughout pregnancy. The aim of this prospective study is to determine the feasibility and reliability of GIUS in pregnant IBD patients. Methods Patients were included when visiting the outpatient IBD pregnancy clinic. At each trimester, clinical and biochemical disease activity was evaluated and GIUS was performed. Feasibility was assessed by the ability to visualise each bowel segment (terminal ileum (TI), ascending (AC), transverse (TC), descending (DC) and sigmoid colon (SC)). Reliability was evaluated by using clinical and biochemical disease activity as a gold standard. This was defined as a Harvey–Bradshaw Index ≥4 in Crohn’s disease (CD) or a Simple Clinical Colitis Activity Index ≥5 in ulcerative colitis and a faecal calprotectin (FCP)³ 250 mg/g. Bowel wall thickness (BWT) of > 3 mm in the colon and > 2mm in the terminal ileum was considered as signs of active inflammation on ultrasound. A Mann–Whitney U-test and chi-square were used for statistical analysis. Results Thirty-two IBD patients (54% CD) were studied. Both a GIUS and FCP was available in 18, 11 and 6 patients for the first, second and third trimester, respectively. Eleven of 32 (34%) patients had clinically active disease at least at one time point during the pregnancy. Table 1 shows the visibility per segment. When the active disease was defined as an FCP ≥ 250 mg/g, GIUS could distinguish active from the non-active disease in the first, second and third trimester with a sensitivity of 80%, 75% and 75% and specificity of 85%, 86% and 100%, respectively. FCP levels were significantly higher in patients with an active disease on GIUS regardless of the trimester (mean 1095.5 ± 1453.8 mg/g vs. 265.25 ± 649.8 mg/g, p < 0.0001). Conclusion GIUS is accurate to distinguish active from the quiescent disease in pregnancy. Feasibility to visualise the TI and the SC decreased during the second and third trimester, although active disease could still be detected. Consequently, GIUS is feasible and reliable to assess disease activity throughout pregnancy in IBD.


BMJ Open ◽  
2019 ◽  
Vol 9 (3) ◽  
pp. e027428 ◽  
Author(s):  
Karoline Freeman ◽  
Brian H Willis ◽  
Hannah Fraser ◽  
Sian Taylor-Phillips ◽  
Aileen Clarke

ObjectiveTest accuracy of faecal calprotectin (FC) testing in primary care is inconclusive. We aimed to assess the test accuracy of FC testing in primary care and compare it to secondary care estimates for the detection of inflammatory bowel disease (IBD).MethodsSystematic review and meta-analysis of test accuracy using a bivariate random effects model. We searched MEDLINE, EMBASE, Cochrane Library and Web of Science until 31 May 2017 and included studies from auto alerts up until 31 January 2018. Eligible studies measured FC levels in stool samples to detect IBD in adult patients with chronic (at least 6–8 weeks) abdominal symptoms in primary or secondary care. Risk of bias and applicability were assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 criteria. We followed the protocol registered as PROSPERO CRD 42012003287.Results38 out of 2168 studies were eligible including five from primary care. Comparison of test accuracy by setting was precluded by extensive heterogeneity. Overall, summary estimates of sensitivity and specificity were not recorded. At a threshold of 50 µg/g, sensitivity from separate meta-analysis of four assay types ranged from 0.85 (95% CI 0.75 to 0.92) to 0.94 (95% CI 0.75 to 0.90) and specificity from 0.67 (95% CI 0.56 to 0.76) to 0.88 (95% CI 0.77 to 0.94). Across three different definitions of disease, sensitivity ranged from 0.80 (95% CI 0.76 to 0.84) to 0.97 (95% CI 0.91 to 0.99) and specificity from 0.67 (95% CI 0.58 to 0.75) to 0.76 (95% CI 0.66 to 0.84). Sensitivity appears to be lower in primary care and is further reduced at a revised threshold of 100 µg/g.ConclusionsConclusive estimates of sensitivity and specificity of FC testing in primary care for the detection of IBD are still missing. There is insufficient evidence in the published literature to support the decision to introduce FC testing in primary care. Studies evaluating FC testing in an appropriate primary care setting are needed.


2020 ◽  
Vol 14 (10) ◽  
pp. 1405-1412 ◽  
Author(s):  
Emma Flanagan ◽  
Emily K Wright ◽  
Jakob Begun ◽  
Robert V Bryant ◽  
Yoon-Kyo An ◽  
...  

Abstract Background and Aims Inflammatory bowel disease [IBD] affects women during their childbearing years. Gastrointestinal ultrasonography [GIUS] accurately identifies disease activity in non-pregnant patients with IBD. The utility of GIUS in pregnancy has not been established. We aimed to determine the feasibility and accuracy of GIUS in the assessment of IBD during pregnancy progression. Methods A multicentre observational study of women with IBD undergoing GIUS during pregnancy. Clinicians assessed the adequacy of bowel views and disease activity in four colonic segments and the terminal ileum. Location[s] in which views were impeded by the uterus were documented. GIUS disease activity [bowel wall thickness >3 mm] was compared with biochemical disease activity [faecal calprotectin >100 μg/g]. Results Ninety patients and 127 GIUS examinations were included [median gestation 19 weeks, range 4–33]. Adequate colonic views were obtained in 116/127 [91%] scans. Adequate ileal views were obtained in 62/67 [93%] scans <20 weeks and 30/51 [59%] scans at 20–26 weeks. There was a positive correlation between bowel wall thickness and calprotectin [r = 0.26, p = 0.03]. GIUS delivered a specificity of 83%, sensitivity of 74%, and negative predictive value of 90% compared with calprotectin. Conclusions GIUS is a feasible and accurate modality for monitoring IBD in pregnancy. Adequate GIUS views of the colon and terminal ileum can be obtained in the majority of patients up to 20 weeks of gestation. Beyond 20 weeks, GIUS provides good views of the colon but the terminal ileum becomes difficult to assess.


BMJ ◽  
2010 ◽  
Vol 341 (jul15 1) ◽  
pp. c3369-c3369 ◽  
Author(s):  
P. F. van Rheenen ◽  
E. Van de Vijver ◽  
V. Fidler

Sign in / Sign up

Export Citation Format

Share Document