Maxillo-facial surgery simulation with a simple patient specific material model

2006 ◽  
Vol 39 ◽  
pp. S206
Author(s):  
J.G. Schmidt ◽  
G. Berti ◽  
T. Hierl
Author(s):  
Davide Campanella ◽  
Gianluca Buffa ◽  
Ernesto Lo Valvo ◽  
Livan Fratini

AbstractMagnesium alloys, because of their good specific material strength, can be considered attractive by different industry fields, as the aerospace and the automotive one. However, their use is limited by the poor formability at room temperature. In this research, a numerical approach is proposed in order to determine an analytical expression of material formability in hot incremental forming processes. The numerical model was developed using the commercial software ABAQUS/Explicit. The Johnson-Cook material model was used, and the model was validated through experimental measurements carried out using the ARAMIS system. Different geometries were considered with temperature varying in a range of 25–400 °C and wall angle in a range of 35–60°. An analytical expression of the fracture forming limit, as a function of temperature, was established and finally tested with a different geometry in order to assess the validity.


Author(s):  
Marinela Peto ◽  
Oscar Aguilar-Rosas ◽  
Erick Erick Ramirez-Cedillo ◽  
Moises Jimenez ◽  
Adriana Hernandez ◽  
...  

Abstract Lattice structures offer great benefits when employed in medical implants for cell attachment and growth (osseointegration), minimization of stress shielding phenomena, and weight reduction. This study is focused on a proof of concept for developing a generic shoulder hemi-prosthesis, from a patient-specific case of a 46 years old male with a tumor on the upper part of his humerus. A personalized biomodel was designed and a lattice structure was integrated in its middle portion, to lighten weight without affecting humerus’ mechanical response. To select the most appropriate lattice structure, three different configurations were initially tested: Tetrahedral Vertex Centroid (TVC), Hexagonal Prism Vertex Centroid (HPVC), and Cubic Diamond (CD). They were fabricated in resin by digital light processing and its mechanical behavior was studied via compression testing and finite element modeling (FEM). The selected structure according to the results was the HPVC, which was integrated in a digital twin of the biomodel to validate its mechanical performance through FEM but substituting the bone material model with a biocompatible titanium alloy (Ti6Al4V) suitable for prostheses fabrication. Results of the simulation showed acceptable levels of Von Mises stresses (325 MPa max.), below the elastic limit of the titanium alloys, and a better response (52 MPa max.) in a model with equivalent elastic properties, with stress performance in the same order of magnitude than the showed in bone’s material model.


2011 ◽  
Vol 03 (02) ◽  
pp. 259-278 ◽  
Author(s):  
YI HAN ◽  
WEI HONG ◽  
LEANN FAIDLEY

Composed of a soft polymer matrix and magnetic filler particles, ferrogel is a smart material responsive to magnetic fields. Due to the viscoelasticity of the matrix, the behaviors of ferrogel are usually rate-dependent. Very few models with coupled magnetic field and viscoelasticity exist in the literature, and even fewer are capable of reliable predictions. Based on the principles of non-equilibrium thermodynamics, a field theory is developed to describe the magneto-viscoelastic property of ferrogel. The theory provides a guideline for experimental characterizations and structural designs of ferrogel-based devices. A specific material model is then selected and the theory is implemented in a finite element code. Through numerical examples, the responses of a ferrogel in uniform and non-uniform magnetic fields are analyzed. The dynamic response of a ferrogel to cyclic magnetic fields is also studied, and the prediction agrees with our experimental results. In the reversible limit, our theory recovers existing models for elastic ferrogel, and is capable of capturing some instability phenomena.


2018 ◽  
Author(s):  
Minliang Liu ◽  
Liang Liang ◽  
Haofei Liu ◽  
Ming Zhang ◽  
Caitlin Martin ◽  
...  

AbstractIt is well known that residual deformations/stresses alter the mechanical behavior of arteries, e.g. the pressure-diameter curves. In an effort to enable personalized analysis of the aortic wall stress, approaches have been developed to incorporate experimentally-derived residual deformations into in vivo loaded geometries in finite element simulations using thick-walled models. Solid elements are typically used to account for “bending-like” residual deformations. Yet, the difficulty in obtaining patient-specific residual deformations and material properties has become one of the biggest challenges of these thick-walled models. In thin-walled models, fortunately, static determinacy offers an appealing prospect that allows for the calculation of the thin-walled membrane stress without patient-specific material properties. The membrane stress can be computed using forward analysis by enforcing an extremely stiff material property as penalty treatment, which is referred to as the forward penalty approach. However, thin-walled membrane elements, which have zero bending stiffness, are incompatible with the residual deformations, and therefore, it is often stated as a limitation of thin-walled models. In this paper, by comparing the predicted stresses from thin-walled models and thick-walled models, we demonstrate that the transmural mean hoop stress is the same for the two models and can be readily obtained from in vivo clinical images without knowing the patient-specific material properties and residual deformations. Computation of patient-specific mean hoop stress can be greatly simplified by using membrane model and the forward penalty approach, which may be clinically valuable.


Author(s):  
Danny Bluestein ◽  
Yared Alemu ◽  
Peter Rissland ◽  
Mikahil Britan ◽  
Idit Avrahami ◽  
...  

Two separate fluid structure interaction (FSI) simulations were performed: a patient-specific Abdominal Aortic Aneurysm (AAA) geometry, and an idealized coronary vulnerable plaque (VP) geometry. VP FSI simulations were later performed in patient based geometries reconstructed from intravascular (IVUS) measurements. (AAA): The patient specific AAA FSI simulation was carried out with both isotropic and anisotropic wall properties. An orthotropic material model was used to describe wall properties, closely approximate experimental results [1]. Results show peak wall stresses are dependent on the geometry of the AAA and the region of highest stress corresponds to expected failure location. The ability to quantify stresses developing within the aneurysm wall based on FSI simulations will facilitate clinicians to reach informed decisions in determining rupture risk of AAA and the need for surgical intervention. (Vulnerable Plaque): To study the risk of rupture of a vulnerable plaque in an idealized coronary artery geometry, an FSI simulation was performed. This model of vulnerable plaque includes vessel wall with calcification spot embedded in the fibrous cap, and a lipid core. Identifying rupture risk, regions susceptible to failure and the contribution of the various components were studied. This work led to predicting the rupture risk in patient specific geometries. The results show the upstream side of vulnerable plaque fibrous cap has the highest stresses. The presence of the calcified spot is shown to enhance stresses within the fibrous cap, significantly contributing to its risk of rupture.


Sign in / Sign up

Export Citation Format

Share Document