Determination of non-steroidal anti-inflammatory analgesics in solid dosage forms by high-performance liquid chromatography on underivatized silica with aqueous mobile phase

1990 ◽  
Vol 504 ◽  
pp. 381-389 ◽  
Author(s):  
Bernhard M. Lampert ◽  
James T. Stewart
2018 ◽  
Vol 2 (1) ◽  
pp. 13-20 ◽  
Author(s):  
Irene C K Guerreiro ◽  
Samuel Davies ◽  
Silvia Guterres ◽  
Simone Jacobus Berlitz

A high-performance liquid chromatography-ultraviolet (HPLC-UV) method was developed and validated for simultaneous determination of Resveratrol (RSV) and Lipoic Acid (LA). A C18 column was used with a mobile phase consisting of acetonitrile and 0.01M phosphoric acid (60:40). The detection wavelength was at 235 nm. The method was specific in the presence of pharmaceutical excipients widely used in solid dosage forms or lipid-core nanocapsules. The results demonstrated linearity between 5 and 50 µg/mL for RSV and 30 and 120 µg/mL for LA. The method presented precision and accuracy (RSD <5%). In addition, the developed method was considered robust. Therefore, the developed method can be applied successfully for simultaneous determination of RSV and LA in the proposed conditions, with a potential application to assay both drugs in several dosage forms.


2007 ◽  
Vol 90 (1) ◽  
pp. 94-101 ◽  
Author(s):  
Fawzy A Elbarbry ◽  
Mokhtar M Mabrouk ◽  
Mohamed A El-Dawy

Abstract A procedure was developed for the determination of the analgesic components of Spasmomigraine® tablets, which are ergotamine (I), propyphenazone (II), caffeine (III), camylofin (IV), and mecloxamine (V). They were subjected to high-performance liquid chromatography on a column (300 × 3.9 mm, 10 μm particle size) packed with μ-Bondapak C18. Separations were achieved with the mobile phase methanol–water–triethylamine (60 + 40 + 0.1, v/v/v) flowing at a rate of 1.5 mL/min, and quantitative determination was performed at 254 nm at ambient temperature for I–III; acetonitrile–25 mM KH2PO4–acetic acid (45 + 55 + 0.2, v/v/v), flowing at a rate of 1.5 mL/min and detection at 234 nm at ambient temperature, was used for IV and V. Methyl paraben was used as an internal standard. The detection limits were 0.35 (I), 5.0 (II), 1.5 (III), 3.0 (IV), and 2.0 g/mL (V). The method was accurate (mean recovery 98 ± 2%, n = 4) and precise (coefficient of variation &lt;5%, n = 5). The proposed method is rapid and sensitive and, therefore, suitable for the routine control of these ingredients in multicomponent dosage forms.


1994 ◽  
Vol 59 (3) ◽  
pp. 569-574 ◽  
Author(s):  
Josef Královský ◽  
Marta Kalhousová ◽  
Petr Šlosar

The reversed-phase high-performance liquid chromatography of some selected, industrially important aromatic sulfones has been investigated. The chromatographic behaviour of three groups of aromatic sulfones has been studied. The optimum conditions of separation and UV spectra of the sulfones and some of their hydroxy and benzyloxy derivatives are presented. The dependences of capacity factors vs methanol content in mobile phase are mentioned. The results obtained have been applied to the quantitative analysis of different technical-grade samples and isomer mixtures. For all the separation methods mentioned the concentration ranges of linear calibration curves have been determined.


2021 ◽  
Vol 66 (3) ◽  
pp. 172-176
Author(s):  
Lyubov Borisovna Kalikova ◽  
E. R. Boyko

Adenine nucleotides (ATP, ADP and AMP) play a central role in the regulation of metabolism and energy: they provide the energy balance of the cell, determine its redox state, act as allosteric effectors of a number of enzymes, modulate signaling and transcription factors and activate oxidation or biosynthesis substrates. A large number of methods have been developed to determine the level of ATP, ADP and AMP, but the most universal and effective method for the separation and analysis of complex mixtures is the reversed-phase high-performance liquid chromatography method (RP-HPLC). The aim of this study is to determine the optimal conditions for the qualitative separation and quantitative determination of standard solutions of ATP (1 mmol/l), ADP (0,5 mmol/l) and AMP (0,1 mmol/l) by RP-HPLC. The degree of separation of adenine nucleotides was estimated by the time of peak output in the chromatogram. To achieve the goal, the following tasks were set: assess the effect of the temperature of the analysis on the separation and change of the release time of the analytes in the chromatogram; determine the most optimal composition of the mobile phase for the separation of ATP, ADP and AMP in the chromatogram (the content of the organic solvent in the solution); to identify the effect of pH of the mobile phase on the separation of standard solutions of adenine nucleotides; set the optimal molarity of the mobile phase for the separation of ATP, ADP and AMP in the chromatogram. It was found that the temperature of the analysis does not affect the quality of peak separation, while the composition and pH of the mobile phase have a significant effect on the complete and clear separation of the studied nucleotides in the chromatogram. It was determined that the analysis temperature of 37°C and the mobile phase of 0.05 M KH2PO4 (pH 6.0) are optimal for separating the peaks of adenine nucleotides.


Author(s):  
Muhammad Fawad Rasool ◽  
Umbreen Fatima Qureshi ◽  
Nazar Muhammad Ranjha ◽  
Imran Imran ◽  
Mouqadus Un Nisa ◽  
...  

AbstractTh accurate rapid, simple and selective reversed phase high performance liquid chromatography (RP-HPLC) has been established and validated for the determination of captopril (CAP). Chromatographic separation was accomplished using prepacked ODSI C18 column (250 mm × 4.6 mm with 5 μm particle size) in isocratic mode, with mobile phase consisting of water: acetonitrile (60:40 v/v), pH adjusted to 2.5 by using 85% orthophosphoric acid at a flow rate of 1 mL/min and UV detection was performed at 203 nm. RP-HPLC method used for the analysis of CAP in mobile phase and rabbit plasma was established and validated as per ICH-guidelines. It was carried out on a well-defined chromatographic peak of CAP was established with a retention time of 4.9 min and tailing factor of 1.871. The liquid–liquid extraction method was used for extraction of CAP from the plasma. Excellent linearity (R2 = 0.999) was shown over range 3.125–100 µg/mL with mean percentage recoveries ranges from 97 to 100.6%. Parameters of precision and accuracy of the developed method meet the established criteria. Intra and inter-day precision (% relative standard deviation) study was also performed which was less than 2% which indicate good reproducibility of the method. The limit of detection (LOD) and quantification for the CAP in plasma were 3.10 and 9.13 ng/mL respectively. The method was suitably validated and successfully applied to the determination of CAP in rabbit plasma samples.


Sign in / Sign up

Export Citation Format

Share Document