Gas–liquid two-phase pressure losses in narrow horizontal annuli

2001 ◽  
Vol 203 (1) ◽  
pp. 107-109 ◽  
Author(s):  
D.R.H Beattie
Author(s):  
John Wesley Coleman

This paper presents the results of an experimental investigation of two-phase pressure loss of R134a in microchannel headers using various end-cut techniques. Novel experimental techniques and test sections were developed to enable the accurate determination of the minor losses without obfuscating the problem with a lengthwise pressure gradient. This technique represents a departure from approaches used by other investigators that have extrapolated minor losses from air-water experiments and the combined effects of expansion, contraction, deceleration, and lengthwise pressure gradients. Pressure losses were recorded over the entire range of qualities from 100% vapor to 100% liquid. In addition, the tests were conducted for five different refrigerant mass fluxes between 185 kg/m2-s and 785 kg/m2-s using two differnt end-cut techniques. More than 790 data points were recorded to obtain a comprehensive understanding of the effects of mass flux and quality on minor pressure losses. High accuracy instrumentation such as coriolis mass flowmeters, RTDs, pressure transducers, and real-time data analyses were used to ensure accuracy in the results. The results show that many of the commonly used correlations for estimating two-phase pressure losses significantly underpredict the pressure losses found in compact microchannel tube headers. Furthermore, the results show that the end-cut technique can substantially affect the pressure losses in microchannel headers. A new model for estimating the pressure loss in microchannel headers is presented and a comparison of the end-cut techniques on the minor losses is reported.


2013 ◽  
Author(s):  
Sung Chan Cho ◽  
Yun Wang

In this paper, two-phase flow dynamics in a micro channel with various wall conditions are both experimentally and theoretically investigated. Annulus, wavy and slug flow patterns are observed and location of liquid phase on different wall condition is visualized. The impact of flow structure on two-phase pressure drop is explained. Two-phase pressure drop is compared to a two-fluid model with relative permeability correlation. Optimization of correlation is conducted for each experimental case and theoretical solution for the flows in a circular channel is developed for annulus flow pattern showing a good match with experimental data in homogeneous channel case.


2012 ◽  
Vol 47 (11-12) ◽  
pp. 717-724
Author(s):  
V. N. Novozhilov ◽  
D. A. Baranov

Sign in / Sign up

Export Citation Format

Share Document