A verification and validation method and its application to digital safety systems in ABWR nuclear power plants

1998 ◽  
Vol 183 (1-2) ◽  
pp. 117-132 ◽  
Author(s):  
Akira Fukumoto ◽  
Toshifumi Hayashi ◽  
Hiroshi Nishikawa ◽  
Hiroshi Sakamoto ◽  
Teruaki Tomizawa ◽  
...  
Author(s):  
Thomas G. Scarbrough

In a series of Commission papers, the U.S. Nuclear Regulatory Commission (NRC) described its policy for inservice testing (IST) programs to be developed and implemented at nuclear power plants licensed under 10 CFR Part 52. This paper discusses the expectations for IST programs based on those Commission policy papers as applied in the NRC staff review of combined license (COL) applications for new reactors. For example, the design and qualification of pumps, valves, and dynamic restraints through implementation of American Society of Mechanical Engineers (ASME) Standard QME-1-2007, “Qualification of Active Mechanical Equipment Used in Nuclear Power Plants,” as accepted in NRC Regulatory Guide (RG) 1.100 (Revision 3), “Seismic Qualification of Electrical and Active Mechanical Equipment and Functional Qualification of Active Mechanical Equipment for Nuclear Power Plants,” will enable IST activities to assess the operational readiness of those components to perform their intended functions. ASME has updated the Operation and Maintenance of Nuclear Power Plants (OM Code) to improve the IST provisions for pumps, valves, and dynamic restraints that are incorporated by reference in the NRC regulations with applicable conditions. In addition, lessons learned from performance experience and testing of motor-operated valves (MOVs) will be implemented as part of the IST programs together with application of those lessons learned to other power-operated valves (POVs). Licensee programs for the Regulatory Treatment of Non-Safety Systems (RTNSS) will be implemented for components in active nonsafety-related systems that are the first line of defense in new reactors that rely on passive systems to provide reactor core and containment cooling in the event of a plant transient. This paper also discusses the overlapping testing provisions specified in ASME Standard QME-1-2007; plant-specific inspections, tests, analyses, and acceptance criteria; the applicable ASME OM Code as incorporated by reference in the NRC regulations; specific license conditions; and Initial Test Programs as described in the final safety analysis report and applicable RGs. Paper published with permission.


2021 ◽  
Vol 30 (4) ◽  
pp. 36-47
Author(s):  
O. S. Lebedchenko ◽  
S. V. Puzach ◽  
V. I. Zykov

Introduction. The reliable operation of safety systems, that allows for the failure of no more than one safety system component, entails the safe shutdown and cool-down of an NPP reactor in the event of fire. However, the co-authors have not assessed the loss of performance by an insulating material, treated by intumescent compositions and used in the power cables of the above safety systems exposed to the simultaneous effect of various modes of fire and current loads.Goals and objectives. The purpose of the article is the theoretical assessment of the application efficiency of intumescent fire-retardant coatings in power cables used in the safety systems of nuclear power plants having water-cooled and water-moderated reactors under fire conditions. To achieve this goal, the temperature of the outer surface of the insulation and the intumescent fire-retardant coating was analyzed depending on the mode of fire. Theoretical foundations. A non-stationary one-dimensional heat transfer equation is solved to identify the temperature distribution inside the multilayered insulation and the fire-protection layer of a conductive core.Results and their discussion. The co-authors have identified dependences between the temperature of the outer surface of the insulation and the fire retarding composition of the three-core cable VVGng (A)-LS 3x2.5-0.66, on the one hand, and the temperature of the indoor gas environment for three standard modes of fire and one real fire mode. It is found that before the initiation of the process of destruction of the insulation material, the intumescence of the fire-retardant coating occurs only in case of a hydrocarbon fire. Under real fire conditions, the maximal insulation melting time before the initiation of intumescence of the fire-retardant coating at the minimal temperature of intumescence is 4.75 minutes, while the maximal time period from the initiation of destruction of the insulation material to the moment of the insulation melting is 6.0 minutes.Conclusions. An experimental or theoretical substantiation of parameters of intumescent fire retardants, performed using standard modes of fire, has proven the potential loss of operational properties by insulating materials of power cables, used in the safety systems of nuclear power plants, in case of a real fire. Therefore, it is necessary to establish a scientific rationale for the efficient use of fire retardants in the above cables with regard for the conditions of a real fire.


Author(s):  
Xiaoyu Cai ◽  
Suizheng Qiu ◽  
Guanghui Su ◽  
Changyou Zhao

The current Light Water Reactors both BWR and PWR have extensive nuclear reactor safety systems, which provide safe and economical operation of Nuclear Power Plants. During about forty years of operation history the safety systems of Nuclear Power Plants have been upgraded in an evolutionary manner. The cost of safety systems, including large containments, is really high due to a capital cost and a long construction period. These conditions together with a low efficiency of steam cycle for LWR create problems to build new power plants in the USA and in the Europe. An advanced Boiling Water Reactor concept with micro-fuel elements (MFE) and superheated steam promises a radical enhancement of safety and improvement of economy of Nuclear Power Plants. In this paper, a new type of nuclear reactor is presented that consists of a steel-walled tube filled with millions of TRISO-coated fuel particles (Micro-Fuel Elements, MFE) directly cooled by a light-water coolant-moderator. Water is used as coolant that flows from bottom to top through the tube, thereby fluidizing the particle bed, and the moderator water flows in the reverse direction out of the tube. The fuel consists of spheres of about 2.5 mm diameter of UO2 with several coatings of different carbonaceous materials. The external coating of steam cycle the particles is silicon carbide (SiC), manufactured with chemical vapor deposit (CVD) technology. Steady-State Thermal-Hydraulic Analysis aims at providing heat transport capability which can match with the heat generated by the core, so as to provide a set of thermal hydraulic parameters of the primary loop. So the temperature distribution and the pressure losses along the direction of flow are calculated for equilibrium core in this paper. The calculation not only includes the liquid region, but the two phase region and the superheated steam region. The temperature distribution includes both the temperature parameters of micro-fuel elements and the coolant. The results show that the maximum fuel temperature is much lower than the limitation and the flow distribution can meet the cooling requirement in the reactor core.


Author(s):  
Steve Yang ◽  
Jun Ding ◽  
Huifang Miao ◽  
Jianxiang Zheng

All 1000 MW nuclear power plants currently in construction or projected to-be-built in China will use the digital instrumentation and control (I&C) systems. Safety and reliability are the ultimate concern for the digital I&C systems. To obtain high confidence in the safety of digital I&C systems, rigorous software verification and validation (V&V) life-cycle methodologies are necessary. The V&V life-cycle process ensures that the requirements of the system and software are correct, complete, and traceable; that the requirements at the end of each life-cycle phase fulfill the requirements imposed by the previous phase; and the final product meets the user-specified requirements. The V&V process is best illustrated via the so-called V-model. This paper describes the V-model in detail by some examples. Through the examples demonstration, it is shown that the process detailed in the V-model is consistent with the IEEE Std 1012-1998, which is endorsed by the US Regulatory Guide 1.168-2004. The examples show that the V-model process detailed in this paper provides an effective V&V approach for digital I&C systems used in nuclear power plants. Additionally, in order to obtain a qualitative mathematical description of the V-model, we study its topological structure in graph theory. This study confirms the rationality of the V-model. Finally, the V&V approach affording protection against common-cause failure from design deficiencies, and manufacturing errors is explored. We conclude that rigorous V&V activities using the V-model are creditable in reducing the risk of common-cause failures.


Sign in / Sign up

Export Citation Format

Share Document