A three-dimensional non-equilibrium model for an intermittent adsorption cooling system

Solar Energy ◽  
2000 ◽  
Vol 69 (1) ◽  
pp. 27-35 ◽  
Author(s):  
L.Z. Zhang
2010 ◽  
Vol 297-301 ◽  
pp. 728-732
Author(s):  
N. Mimouni ◽  
Salahs Chikh ◽  
Rachid Bennacer

A 3D numerical analysis is carried out to investigate heat and mass transfer in a partly porous cavity of high aspect ratio. The goal is to determine the best physical and geometrical parameters that allow optimal heat and mass transfer rate in such domain used in a solar adsorption cooling system. The computational domain consists of a tall cavity heated on the left vertical wall and cooled on the opposing wall. The SIMPLE algorithm is used to handle the velocity pressure coupling. Simulation results allow determining the optimal configuration of the used porous substrate and plain fluid position in the cavity in order to optimize the performance of such solar adsorption cooling installation.


2019 ◽  
Vol 27 (02) ◽  
pp. 1950014
Author(s):  
Ngoc Vi Cao ◽  
Xuan Quang Duong ◽  
Woo Su Lee ◽  
Jae Dong Chung

A three-dimensional numerical analysis was conducted to examine the effect on performance of un-balanced heating/cooling water supply and nonuniform pressure distribution in the beds, issues observed in an experiment by our colleague during the development of a 35[Formula: see text]kW prototype finned-tube type adsorption chiller. Case studies were conducted with reference values of [Formula: see text][Formula: see text]m/s, [Formula: see text][Formula: see text]Pa and [Formula: see text][Formula: see text]Pa, and the differences in [Formula: see text][Formula: see text]m/s, [Formula: see text][Formula: see text]Pa and [Formula: see text][Formula: see text]Pa. A remarkable increase in COP was found for the cases of un-balanced heating water supply and nonuniform pressure distribution when the bed was connected to the evaporator. However, after integration of multi-modules, the effect was smoothed out, which removed the worry about the degradation in the overall COP. The effect of un-balanced cooling water supply and nonuniform pressure distribution when the bed was connected to the condenser was not discernible. In all cases, the change in SCP was negligible.


2012 ◽  
Vol 5 (2) ◽  
pp. 144-149
Author(s):  
Montasser S. Tahat ◽  
Abdulmajeed S. Al-Ghamdi ◽  
Mohammad Q. Al-Odat

2020 ◽  
Vol 6 ◽  
pp. 168-173
Author(s):  
Ahmed A. Hassan ◽  
Ahmed E. Elwardany ◽  
Shinichi Ookawara ◽  
Ibrahim I. El-Sharkawy

2014 ◽  
Vol 16 (27) ◽  
pp. 13974-13983 ◽  
Author(s):  
V. N. Kuzovkov ◽  
G. Zvejnieks ◽  
E. A. Kotomin

The 3d structure of self-assembled and oppositely charged nanoparticles.


Sign in / Sign up

Export Citation Format

Share Document