Stoichiometric and kinetic model parameters for microbial transformations of suspended solids in combined sewer systems

1999 ◽  
Vol 33 (14) ◽  
pp. 3127-3141 ◽  
Author(s):  
Jes Vollertsen ◽  
Thorkild Hvitved-Jacobsen
1997 ◽  
Vol 36 (8-9) ◽  
pp. 95-100 ◽  
Author(s):  
Robin G. Veldkamp ◽  
Jan B. M. Wiggers

This research is based on CSO emissions from Dutch sewer systems. During the years 1982 to 1989 research was done on several sewer systems, all of them equiped with a single overflow weir. Pollutant emissions were calculated from the measurements, whereby each storm was considered as a single event. Extreme emissions have a detrimental, sometimes even desastrous effect on water quality. Such extreme emissions are the result of heavy storms, giving it a low frequency of occurrence. From the measurements a statistical model was developed enabling the user to forecast extreme waste emissions with a certain return period in a range of 2 to 10 years. Five pollutants are put in the model: BOD, COD, Kjeldahl nitrogen, total phosphate and suspended solids. The model operates with standardized emission values in kg per ha of impervious area. When the model is used in practice the runoff area to the specific overflow under consideration has to be known.


1994 ◽  
Vol 21 (6) ◽  
pp. 924-930 ◽  
Author(s):  
Jean-Pierre Villeneuve ◽  
Eric Gaume ◽  
France Michaud

Municipalities try to limit overflow of their sewer systems by various technologies such as storage in basins and transfer of the water after the storm to a treatment facility, storage and decantation, on-line treatment of overflows, or by alternative technologies like porous roadways or runoff infiltration. The swirl separator, proposed by the American Public Work Association, is an attractive device, because it requires little supervision and maintenance. However, only few results exist about its efficiency for treating combined sewer overflow. The purpose of the present field study was to determine the performance of an existing device (the Québec swirl regulator). The results, presented herein, show that up to 25% of the suspended solids transported during storms can be eliminated, but most of the liquid–solid separation seems to take place in the upstream collecting pipe. Key words: combined sewers, overflows, water treatment, suspended sediments.


2014 ◽  
Vol 69 (8) ◽  
pp. 1751-1758 ◽  
Author(s):  
A. Hannouche ◽  
G. Chebbo ◽  
C. Joannis

A large database of continuous flow and turbidity measurements cumulating data on hundreds of rain events and dry weather days from two sites in Paris (called Quais and Clichy) and one in Lyon (called Ecully) is presented. This database is used to characterize and compare the behaviour of the three sites at the inter-events scale. The analysis is probed through three various variables: total volumes and total suspended solids (TSS) masses and concentrations during both wet and dry weather periods in addition to the contributions of diverse-origin sources to event flow volume and TSS load values. The results obtained confirm the previous findings regarding the spatial consistency of TSS fluxes and concentrations between both sites in Paris having similar land uses. Moreover, masses and concentrations are proven to be correlated between Parisian sites in a way that implies the possibility of some deterministic processes being reproducible from one catchment to another for a particular rain event. The results also demonstrate the importance of the contribution of wastewater and sewer deposits to the total events' loads and show that such contributions are not specific to Paris sewer networks.


1994 ◽  
Vol 30 (1) ◽  
pp. 63-71 ◽  
Author(s):  
C. Jefferies ◽  
R. M. Ashley

The behaviour of gross and visible solids was studied at two combined sewer overflow sites using the WRc Gross Solids Sampler. At one of the sites the daily variation of gross solids during dry weather was determined. There was found to be close correspondence between the variations of gross and suspended solids in the sewage. A relationship was developed between the load of gross solids and that of suspended solids at the observation point in dry weather. This relationship is presented for use with other predictive methods. A chart is presented which differentiates with a high degree of reliability the gross solids production of two different types of catchments, one being a collector sewer catchment, the other being a trunk. The rate of gross solids production has been found to be a critical factor in differentiating between the catchments. A consistent and further differentiation in the accumulation of gross solids is presented on the basis of antecedent dry period, greater than 24h allowing considerably greater accumulations than shorter dry periods.


2005 ◽  
Vol 52 (5) ◽  
pp. 135-142 ◽  
Author(s):  
A. Kanso ◽  
G. Chebbo ◽  
B. Tassin

Previous research has confirmed that the sediments at the bed of combined sewer systems are the main source of particulate and organic pollution during rain events contributing to combined sewer overflows. However, existing urban stormwater models utilize inappropriate sediment transport formulas initially developed from alluvial hydrodynamics. Recently, a model has been formulated and profoundly assessed based on laboratory experiments to simulate the erosion of sediments in sewer pipes taking into account the increase in strength with depth in the weak layer of deposits. In order to objectively evaluate this model, this paper presents a Bayesian analysis of the model using field data collected in sewer pipes in Paris under known hydraulic conditions. The test has been performed using a MCMC sampling method for calibration and uncertainty assessment. Results demonstrate the capacity of the model to reproduce erosion as a direct response to the increase in bed shear stress. This is due to the model description of the erosional strength in the deposits and to the shape of the measured bed shear stress. However, large uncertainties in some of the model parameters suggest that the model could be over-parameterised and necessitates a large amount of informative data for its calibration.


1984 ◽  
Vol 16 (8-9) ◽  
pp. 311-325 ◽  
Author(s):  
N B Johansen ◽  
P Harremoës ◽  
M Jensen

Overflow from combined systems constitute an increasing source of pollution of receiving waters, as compared to daily wastewater discharges which undergo treatment to a still higher extent. The receiving water problems from overflows are significant both in a long term scale (mean annual load) and in a short term scale (extreme event load). A method for computation of both annual and extreme load is presented. It is based on historical rain series and the use of a time-area model and simple pollutant mixing model in runoff calculation. Statistical calculations for both mean annual load and extreme events have been applied to the computed overflow series. Based on the computerized method simple manual calculations methods have been developed, resulting in graphs and tables for annual load and extreme load.


1995 ◽  
Vol 32 (2) ◽  
pp. 95-103
Author(s):  
José A. Revilla ◽  
Kalin N. Koev ◽  
Rafael Díaz ◽  
César Álvarez ◽  
Antonio Roldán

One factor in determining the transport capacity of coastal interceptors in Combined Sewer Systems (CSS) is the reduction of Dissolved Oxygen (DO) in coastal waters originating from the overflows. The study of the evolution of DO in coastal zones is complex. The high computational cost of using mathematical models discriminates against the required probabilistic analysis being undertaken. Alternative methods, based on such mathematical modelling, employed in a limited number of cases, are therefore needed. In this paper two alternative methods are presented for the study of oxygen deficit resulting from overflows of CSS. In the first, statistical analyses focus on the causes of the deficit (the volume discharged). The second concentrates on the effects (the concentrations of oxygen in the sea). Both methods have been applied in a study of the coastal interceptor at Pasajes Estuary (Guipúzcoa, Spain) with similar results.


1992 ◽  
Vol 26 (5-6) ◽  
pp. 1295-1304 ◽  
Author(s):  
C. Jefferies

Visible pollution discharged from two combined sewer overflows were studied using passive Trash Trap devices and the UK Water Research Centre Gross Solids Sampler. Relationships are presented for the number of visible solids and the mass of gross solids discharged during an event. The differences in the behaviour of the overflow types are reported on and they are categorised using the Trash Traps.