OCCULT BLOOD AND FAECAL LEUCOCYTE TESTS IN ACUTE INFECTIOUS DIARRHOEA IN CHILDREN

The Lancet ◽  
1987 ◽  
Vol 329 (8530) ◽  
pp. 442 ◽  
Author(s):  
Susanna Paccagnini ◽  
Rossana Ceriani ◽  
Luciana Galli ◽  
Nicola Principi ◽  
Massimo Fontana ◽  
...  
2016 ◽  
Vol 25 (1) ◽  
pp. 71-77 ◽  
Author(s):  
Ashley D. Bond ◽  
Michael D. Burkitt ◽  
David Sawbridge ◽  
Bernard M. Corfe ◽  
Chris S. Probert

Background & Aims: Colorectal cancer screening programmes that target detection and excision of adenomatous colonic polyps have been shown to reduce colorectal cancer related mortality. Many screening programmes include an initial faecal occult blood test (FOBt) prior to colonoscopy. To refine the selection of patients for colonoscopy other faecal-based diagnostic tools have been proposed, including tumour M2-pyruvate kinase (tM2-PK). To determine whether tM2-PK quantification may have a role in diverse settings we have assessed the assay in a cohort of patients derived from both the England bowel cancer screening programme (BCSP) and symptomatic individuals presenting to secondary care. Method. Patients undergoing colonoscopy provided faecal samples prior to bowel preparation. Faecal tM2-PK concentrations were measured by ELISA. Sensitivity, specificity, positive predictive value, negative predictive value and ROC analyses were calculated. Results. Ninety-six patients returned faecal samples: 50 of these with adenomas and 7 with cancer. Median age was 68. Median faecal tM2-PK concentration was 3.8 U/mL for individuals without neoplastic findings at colonoscopy, 7.7 U/mL in those with adenomas and 24.4 U/mL in subjects with colorectal cancer (both, p=0.01). ROC analysis demonstrated an AUROC of 0.66 (sensitivity 72.4%, specificity 48.7%, positive predictive value 67.7%, negative predictive value 36.7%). Amongst BCSP patients with a prior positive FOBt faecal tM2-PK was more abundant (median 6.4 U/mL, p=0.03) and its diagnostic accuracy was greater (AUROC 0.82). Conclusion. Our findings confirm that faecal tM2-PK ELISA may have utility as an adjunct to FOBt in a screening context, but do not support its use in symptomatic patients. Abbreviations: BCSP: Bowel cancer screening programme; EMR: Endoscopic mucosal resection; FAP: Familial adenomatous polyposis; FOBt: Faecal occult blood testing; NHS: National Health Service; tM2-PK: tumour M2-pyruvate kinase.


2020 ◽  
Vol 57 (3) ◽  
pp. 316-322
Author(s):  
Rejane MATTAR ◽  
Sergio Barbosa MARQUES ◽  
Maurício Kazuyoshi MINATA ◽  
Joyce Matie Kinoshita da SILVA-ETTO ◽  
Paulo SAKAI ◽  
...  

ABSTRACT BACKGROUND: Rectal bleeding is the most important symptom of intestinal neoplasia; thus, tests of occult blood detection in stools are widely used for pre neoplastic lesions and colorectal cancer (CRC) screening. OBJECTIVE: Evaluate the accuracy of OC-Sensor quantitative test (Eiken Chemical, Tokyo, Japan) at cut-off 10 µg Hb/g feces (50 ng/mL) in a cohort of subjects that had to undergo diagnostic colonoscopy, and if more than one sample collected in consecutive days would improve the diagnostic accuracy of the test. METHODS: Patients (mean age 56.3±9.7 years) that underwent colonoscopy prospectively randomly received one (1-sample FIT, FIT 1) or two (2-sample FIT, FIT 2) collection tubes. They collected the stool sample before starting colonoscopy preparation. Samples were analyzed by the OC-Auto Micro 80 (Eiken Chemical, Tokyo, Japan). The performance of FIT 1 and FIT 2 were compared to the colonoscopy findings. RESULTS: Among 289 patients, CRC was diagnosed in 14 (4.8%), advanced adenoma in 37 (12.8%), early adenoma in 71 (24.6%) and no abnormalities in 141 (48.8%). For FIT 1, the sensitivity for CRC was 83.3% (95%CI 36.5-99.1%), for advanced adenoma was 24% (95%CI 10.1-45.5%), with specificity of 86.9% (95%CI 77.3-92.9%). For FIT 2, the sensitivity for CRC was 75% (95%CI 35.6-95.5%), for advanced adenoma was 50% (95%CI 22.3-77.7%), with specificity of 92.9% (95%CI 82.2-97.7%). The positive likelihood ratios were 1.8 (95%CI 0.7-4.4 for FIT 1) and 7.1 (95%CI 2.4-21.4 for FIT 2) for advanced adenoma, and 6.4 (95%CI 3.3-12.3, for FIT 1) and 10.7 (95%CI 3.8-29.8, for FIT 2) for CRC. The negative likelihood ratio were 0.9 (95%CI 0.7-1, for FIT 1) and 0.5 (95%CI 0.3-0.9, for FIT 2) for advanced adenoma, and 0.2 (0.03-1.1, for FIT 1) and 0.3 (0.08-0.9, for FIT 2) for CRC. The differences between FIT 1 and FIT 2 performances were not significant. However, the comparison of the levels of hemoglobin in feces of patients of FIT 1 and FIT 2 showed that the differences between no polyp group and advanced adenoma and CRC were significant. CONCLUSION: The accuracy of OCR Sensor with 10 µg Hb/g feces cut-off was comparable to other reports and two-sample collection improved the detection rate of advanced adenoma, a pre neoplastic condition to prevent CRC incidence.


Sign in / Sign up

Export Citation Format

Share Document