scholarly journals EP-1248: A video camera tracking system-based evaluation of SynchronyÆ accuracy

2013 ◽  
Vol 106 ◽  
pp. S471
Author(s):  
Y. Kumazaki ◽  
N. Tsukamoto ◽  
T. Nakamura ◽  
R. Miyakawa ◽  
K. Kinouchi ◽  
...  
Author(s):  
A.V. Bobkov ◽  
G.V. Tedeev

The article proposes a multi-camera tracking system for an object, implemented using computer vision technologies and allowing the video surveillance operator in real time to select an object that will be monitored by the system in future. It will be ready to give out the location of the object at any time. The solution to this problem is divided into three main stages: the detection stage, the tracking stage and the stage of interaction of several cameras. Methods of detection, tracking of objects and the interaction of several cameras have been investigated. To solve the problem of detection, the method of optical flow and the method of removing the background were investigated, to solve the problem of tracking — the method of matching key points and the correlation method, to solve the problem of interaction between several surveillance cameras — the method of the topological graph of a network of cameras. An approach is proposed for constructing a system that uses a combination of the background removal method, the correlation method and the method of the topological graph of a network of cameras. The stages of detection and tracking have been experimentally implemented, that is, the task of tracking an object within the coverage area of one video camera has been solved. The implemented system showed good results: a sufficiently high speed and accuracy with rare losses of the tracked object and with a slight decrease in the frame rate.


2017 ◽  
Vol 58 (1) ◽  
pp. 169-176 ◽  
Author(s):  
Javier Miñano-Espin ◽  
Luis Casáis ◽  
Carlos Lago-Peñas ◽  
Miguel Ángel Gómez-Ruano

AbstractReal Madrid was named as the best club of the 20th century by the International Federation of Football History and Statistics. The aim of this study was to compare if players from Real Madrid covered shorter distances than players from the opposing team. One hundred and forty-nine matches including league, cup and UEFA Champions League matches played by the Real Madrid were monitored during the 2001-2002 to the 2006-2007 seasons. Data from both teams (Real Madrid and the opponent) were recorded. Altogether, 2082 physical performance profiles were examined, 1052 from the Real Madrid and 1031 from the opposing team (Central Defenders (CD) = 536, External Defenders (ED) = 491, Central Midfielders (CM) = 544, External Midfielders (EM) = 233, and Forwards (F) = 278). Match performance data were collected using a computerized multiple-camera tracking system (Amisco Pro®, Nice, France). A repeated measures analysis of variance (ANOVA) was performed for distances covered at different intensities (sprinting (>24.0 km/h) and high-speed running (21.1-24.0 km/h) and the number of sprints (21.1-24.0 km/h and >24.0 km/h) during games for each player sectioned under their positional roles. Players from Real Madrid covered shorter distances in high-speed running and sprint than players from the opposing team (p < 0.01). While ED did not show differences in their physical performance, CD (p < 0.05), CM (p < 0.01), EM (p < 0.01) and F (p > 0.01) from Real Madrid covered shorter distances in high-intensity running and sprint and performed less sprints than their counterparts. Finally, no differences were found in the high-intensity running and sprint distances performed by players from Real Madrid depending on the quality of the opposition.


2012 ◽  
Vol 11 (2) ◽  
pp. 315-334 ◽  
Author(s):  
Javed Ahmed ◽  
Ahmad Ali ◽  
Asifullah Khan

2008 ◽  
Vol 2 (3) ◽  
Author(s):  
Kimberly Ryland ◽  
Carl A. Nelson ◽  
Thomas Hejkal

Retinopathy of prematurity, caused by abnormal blood vessel development in the retina of premature infants, is a leading cause of childhood blindness. It is treated using laser photocoagulation. Current methods require the surgeon to assume awkward standing positions, which can result in injury to the surgeon if repeated often. To assist surgeons in providing quality care and prevent occupational injury, a new infant surgical table was designed. The engineered solution is an attachment to a standard surgical table, saving cost and space. The adjustable height and tilt provided by the standard table combined with the 360 deg rotation designed into the attachment allow the surgeon to sit during surgery. The infant table incorporates several novel features. Critical cords and tubes are routed through an aperture at the center of the attachment to avoid pulling and kinking. A four-bar locking mechanism allows easy attachment to standard medical railing. A straight-line mechanism provides positive locking of the rotation, allowing precise positioning of the infant. Load-deflection testing was carried out using an infrared camera tracking system, and expert feedback was also obtained in a clinical setting to ascertain proper function. Strength testing showed acceptably small deflections and stresses under representative loading conditions. Benchtop and clinical testing of the infant table have demonstrated that it reliably and safely meets the design objectives. The device also shows promise for use in other infant or pediatric treatment and in small-animal veterinary practice.


Sign in / Sign up

Export Citation Format

Share Document