Fractures of the Distal Radius and Scaphoid

1996 ◽  
Vol 21 (6) ◽  
pp. 772-774 ◽  
Author(s):  
J. OSKAM ◽  
J. S. DE GRAAF ◽  
H. J. KLASEN

Simultaneous fractures of the distal radius and scaphoid is an uncommon wrist injury. During the period 1980 to 1993, 23 patients with a median age of 39 years were treated for this injury. The median follow-up period was 7 years. All scaphoid fractures were undisplaced and located in the waist or distal third. An extraarticular distal radial fracture was observed in 15 wrists. A below elbow cast including the thumb was applied in 18 wrists for a mean duration of 9 weeks, and operative treatment was used in only 5 patients. All scaphoid fractures healed without complications. During conservative treatment there were three redisplacements of distal radial fractures. The final functional results were good in 18, fair in four, and poor in one patient. Because complications occurred at the distal radius we have changed our conservative treatment policy from a below elbow cast including the thumb to a dorsal splint for 6 weeks.

2005 ◽  
Vol 13 (2) ◽  
pp. 153-157 ◽  
Author(s):  
KK Wong ◽  
KW Chan ◽  
TK Kwok ◽  
KH Mak

Purpose. To evaluate the functional and radiological results of treating unstable fractures of the dorsal distal radius with a volar locking plate. Methods. Dorsally displaced distal radial fractures in 30 patients (11 men and 19 women; mean age, 58.6 years) were fixed by volar locking compression plate and followed up for a minimum of one year. Results. At final functional assessment, 24 patients achieved excellent and 5 achieved good outcomes, with one patient exhibiting fair results. Radiological scores demonstrated 22 excellent and 8 good outcomes. No nonunion or infection occurred. Conclusion. Volar locking compression plating is a safe and effective treatment for unstable fractures of the dorsal distal radius.


2012 ◽  
Vol 38 (7) ◽  
pp. 710-717 ◽  
Author(s):  
S. Krämer ◽  
H. Meyer ◽  
P. F. O’Loughlin ◽  
B. Vaske ◽  
C. Krettek ◽  
...  

Two hundred distal radial fractures, with a mean follow up of 20 months (range 6–49), were divided into three groups according to the presence and healing status of an ulnar styloid fracture. The patients underwent both clinical and radiological examination and completed two different questionnaires. One hundred and one, of 200 distal radial fractures, were associated with an ulnar styloid fracture. Forty-six of these developed an ulnar styloid nonunion. The authors encountered significantly higher pain scores (ulnar sided pain p = 0.012), a higher rate of DRUJ instability ( p = 0.032), a greater loss of motion and grip strength ( p = 0.001), and a poorer clinical outcome in cases with an ulnar styloid fracture, but no differences were apparent when those with healed ulnar styloid fractures or ulnar styloid nonunions were compared ( p > 0.05). The investigators propose that the incidence of ulnocarpal complaints following distal radial fracture depends on the presence but not the healing status of an ulnar styloid fracture.


Author(s):  
Gaetano Caruso ◽  
Francesco Tonon ◽  
Alessandro Gildone ◽  
Mattia Andreotti ◽  
Roberto Altavilla ◽  
...  

Abstract Background Distal radial fractures are common traumatic injuries, but their management remains controversial also in case of conservative treatment regarding the type of immobilisation. Hence, we conducted a two-arm, parallel-group, prospective randomised trial to compare the capacity of long casts (above-elbow) and short casts (below-elbow) to maintain the reduction of extra-articular distal radius fractures with dorsal displacement (AO/OTA classification: 2R3A2.2). Methods Seventy-four eligible patients with AO/OTA 2R3A2.2 fractures treated with closed reduction and cast immobilisation were randomised to the long cast group (n°= 37) or to the short cast group (n°= 37). Baseline radiological parameters, radial inclination (RI), radial height (RH), ulnar variance (UV) and palmar tilt (PT) were taken, and compared with clinical (DASH, Mayo Wrist and Mayo Elbow) and radiological scores taken at 7–10 days, 4 weeks and 12 weeks. Furthermore, to evaluate correlations between radiological parameters and functional outcomes, patients were divided into two groups according to whether or not their radiological parameters at Follow-ups 2 and 3 were acceptable, i.e. within the range 11–12 mm for RH, 16°–28° for RI, − 4–+ 2 mm for UV and 0°–22° for PT. Results Patient demographic and baseline radiological parameters were similar between groups. At follow-up, there were no statistically significant differences between the two types of cast in terms of RI, RH, UV or PT, or Mayo wrist or DASH scores. Short cast group patients displayed better Mayo elbow score at follow-up 2 (4 weeks), but this difference was no longer statistically significant at follow-up 3 (12 weeks). No statistically significant differences in clinical outcomes were found between patients who presented acceptable radiographic parameters at follow-up and those who did not. Conclusion As there were no significant differences between short casts and long casts in terms of fracture reduction maintenance or clinical outcomes, short casts are an effective method of post-reduction immobilisation in AO/OTA 2R3A2.2 fracture of the radius. Radiological parameters outside the range conventionally considered acceptable do not preclude a satisfactory clinical outcome. Trial registration ClinicalTrials.gov PRS, NCT04062110. Registred 20 August 2019.


1994 ◽  
Vol 19 (3) ◽  
pp. 384-388 ◽  
Author(s):  
L. M. HOVE

Simultaneous fractures of the distal radius and scaphoid are uncommon. In a prospective 3-year study we registered 2,330 distal radial fractures and 390 scaphoid fractures, and 12 were combined. Ten of these had high energy trauma; six were styloid fractures, four Colles’ fractures, one was a greenstick fracture and one Salter–Harris Type 2 epiphyseal fracture. All but one of the 12 scaphoid fractures were stable and healed without problems, and one was a trans-scaphoid, trans-styloid peri-lunate fracture-dislocation. The study supports the opinion that the distal radial fracture constitutes the principal injury that determines the outcome and hence the treatment. If the scaphoid fracture is unstable or dislocated, we recommend internal fixation of the scaphoid. Only a small proportion of these injuries represent a more serious disruption with carpal instability.


2021 ◽  
Author(s):  
Yang Liu ◽  
Muhammad Zeeshan Waheed ◽  
Dong Wang ◽  
Junlin Zhou

Abstract Background: Unstable distal radial fractures are difficult to manage and so various treatment and management modalities have been introduced and described. The use of Volar Rim Distal Radius Plate is promoted for the management of such fractures. Objective: This study aimed to to investigate the clinical effect and functional output of Volar Rim Distal Radius Plate in the treatment of distal radius fractures. The purpose of this study is to evaluate the functional and radiological results of treating distal radial fractures with Volar Rim Distal Radius Plate Methods: In our study from March 2017 to may 2019, the clinical efficacy of Volar Rim Distal Radius Plate in the treatment of distal radius fractures was retrospectively analyzed. Case Description: During the study period, 23 patients met the inclusion criteria. According to the AO lassification of distal radius, there were 9 patients with Ao-23b3 and 14 patients with Ao-23c3. The follow-up ime was 13-17 months (average 14.6 months). All patients achieved bony union without internal fixation failure or racture displacement. The Garland and Werley functional system score was used to evaluate the limb function. Among them, 9 cases were evaluated as excellent, 13 cases as good, and 1 case as fair. Radiological parameters such as radial inclination, length, tilt, and ulnar variance were measured at six weeks and at the final follow-up. The functional evaluation was conducted by measuring the range of motion at the wrist joint as well as the grip strength. Gartland and Werley’s demerit scoring system was used to assess the final outcome. Literature Review: Results without nonoperative treatment of these fractures are not satisfactory and may often require a subsequent corrective osteotomy.Good and Satisfactory results Can be achieved with operative treatment of the fracture when the fragments are well reduced by using theVolar Rim Distal Radius Plate。 Results: There was a significant improvement in the functional indices from six weeks to the final follow-up, while the radiological parameters were maintained. According to Gartland and Werley, excellent results were reported in 65% cases, while good results were present in 35% cases. Clinical Relevance: Volar Rim Distal Radius Plate can give an adequate buttress to volar projection of the lunate facet and it do not interfere with wrist mobility. More-ever, the dorsal fragments can be fixed through the volar approach which may eliminate our need for a secondary posterior incision. Furthermore, patients would be informed for the potential problems and let them know about the need of the removal of the plate if unfortunately symptoms develop. Conclusions: The use of Volar Rim Distal Radius Plate is an effective fixation method to treat distal radius fractures which can provide more firm stability, meet the needs of early functional exercise and improve the prognosis with excellent to good functional outcomes with minimal complications.


2019 ◽  
Vol 44 (5) ◽  
pp. 468-474 ◽  
Author(s):  
Grace T.W. Sun ◽  
Simon B.M. MacLean ◽  
Justin J. Alexander ◽  
Richard Woodman ◽  
Gregory I. Bain

Scapholunate dissociation may occur in association with distal radial fractures and is easily missed at initial presentation. The aim of this study was to examine variances in the scapholunate distance with respect to subtypes of two-part partial articular distal radial fractures. Axial computed tomography (CT) scans of acute two-part intra-articular radial fractures were assessed retrospectively from 80 patients and compared to 20 controls. From each scan, two images were analysed to identify the scaphoid, lunate and articular fracture line in the distal radius for fracture type categorization. The images were overlaid on a standardized distal radius template and the scapholunate distance measured. Significant increase in the scapholunate distance was noted in fracture subtypes: radial styloid oblique; dorsal ulnar column; sagittal ulnar column; and volar coronal. We conclude that these findings support the need for a higher index of suspicion for scapholunate dissociation in these distal radial fracture subtypes. Level of evidence: III


2002 ◽  
Vol 10 (2) ◽  
pp. 179-184 ◽  
Author(s):  
JA Mehta ◽  
JP Slavotinek ◽  
J Krishnan

Purpose. To assess the restoration of the bone mass of the distal radius following the use of implants in the distal radial fragment. Highly comminuted Frykman type 7 and 8 fractures were studied to determine whether the use of fixation pins in the comminuted distal radial fragment leads to osteopenia in the distal radial fragment after healing of the fracture. Methods. As part of a clinical trial, 30 patients with comminuted intra-articular fractures of the distal radius were treated with closed reduction, external non-bridging fixation, and early postoperative mobilisation. To detect local osteopenia, bone density measurements were taken at the distal metaphysis and mid-diaphysis following healing of the fractured radius and the contralateral unaffected radius in 12 patients. Results. The mean age of the 12 patients for whom bone density measurements were recorded was 52.5 years (range, 39–87 years). There were 9 females and 3 males included in the study. Seven patients had a Frykman type 8 fracture and 5 patients had a Frykman type 7 fracture. Significant osteopenia was absent despite the use of four 2.5-mm fixation pins in the distal fragments of the healed distal radial fracture. The median value of the maximal step was 2.8mm (range, 0–9.1mm). The median value of the intra-articular interfragmentary gap was 1.8 mm (range, 0–13.4mm). Conclusion. The findings of this study do not suggest long-term osteopenia following the use of four 2.5-mm pins in the distal fragments. The non-bridging fixator, by allowing early physical activity, possibly led to satisfactory functional and structural results.


Hand ◽  
2021 ◽  
pp. 155894472110289
Author(s):  
Anthony L. Logli ◽  
Marco Rizzo

Background: Owing to the many unique disease characteristics of Parkinson disease (PD)—namely resting tremors, muscular rigidity, and poor bone quality—we hypothesized that this patient population would have inferior outcomes with surgical management of acute distal radius fractures (DRFs) compared with the literature available on the general population. Methods: This is a retrospective observational study performed at a single, level 1, academic center from 2001 to 2020 capturing all adult patients with an isolated, acute, and closed DRF that ultimately underwent operative treatment. International Classification of Diseases 10 codes were used to identify 30 patients for manual chart review. Several patient and fracture characteristics were accounted for and complications, reoperations, and failures of surgical intervention were recorded. Results: There was a total of 7/30 failures (23%), 6/30 reoperations (20%), and 12 complications in 9/30 wrists (complication rate, 30%) at a mean latest follow-up of 11 months (1.2-158 months). Of the 7 failures, 5 were due to loss of reduction, and 2 of them were deep infections with mean time to failure of 8.3 weeks (range, 11 days-5.2 months). Conclusions: This study found a high rate of complications, reoperations, and early failure despite a short follow-up period and a small cohort of patients with PD treated surgically for a DRF. We recommend locked plating if suitable for the fracture type and early involvement of a multidisciplinary team to assist with medical optimization of PD to increase chances of a successful outcome.


2020 ◽  
Vol 9 (3) ◽  
Author(s):  
Felipe Azevedo Mendes de Oliveira ◽  
Thiago Agostini Pereira Albeny ◽  
Luis Guilherme Rosifini Alves Rezende ◽  
Filipe Jun Shimaoka ◽  
Amanda Favaro Cagnolati ◽  
...  

Objetivo: Avaliar o perfil epidemiológico das fraturas do rádio distal em hospitais de referência em Ribeirão Preto(SP), Brasil. Não existem dados suficientes na literatura nacional que corroborem com o perfil epidemiológico das fraturas do rádio distal. Métodos: 245 pacientes apresentaram 254 fraturas do rádio distal, ocorridas entre 2014 a 2017 foram avaliadas retrospectivamente para obtenção do perfil epidemiológico. Os fatores analisados foram idade e sexo, mecanismo do trauma, sazonalidade, tipo de fratura baseada na Classificação AO, presença de exposição óssea, lesões associadas, tipo de tratamento realizado (conservador ou cirúrgico) e o tipo de implante utilizado nos tratamentos cirúrgicos. Resultados: 60,2% dos pacientes participantes eram do sexo masculino e 39,8% do sexo feminino, distribuídos de forma bimodal. A média de idade foi 45,4 anos. Fraturas expostas corresponderam a 92,1% das fraturas e 7,9% representaram as expostas. Pacientes politraumatizados representaram 62,6%. O tempo médio de internação foi 8,09 dias. Conclusão: Apesar do padrão de fraturas mostrar semelhanças com outros estudos, o padrão apresentado pode não traduzir, de forma homogênea, o padrão obtido em outras metrópoles e grandes centros.Descritores: Fraturas do Rádio; Traumatismos do Punho; Epidemiologia; Hospitais Especializados.ReferênciasBruce KK, Merenstein DJ, Narvaez MV, Neufeld SK, Paulus MJ, Tan TP et al. Lack of Agreement on Distal Radius Fracture Treatment. J Am Board Fam Med. 2016;29(2):218-25.MacIntyre NJ, Dewan N. Epidemiology of distal radius fractures and factors predicting risk and prognosis. J Hand Ther. 2016;29(2):136-45.Court-Brown CM, Caesar B. Epidemiology of adult fractures: A review. Injury. 2006;37(8):691-97.Nellans KW, Kowalski E, Chung KC. The epidemiology of distal radius fractures. Hand Clin. 2012;28(2):113-25. Flinkkilä T, Sirniö K, Hippi M, Hartonen S, Ruuhela R, Ohtonen P et al. Epidemiology and seasonal variation of distal radius fractures in Oulu, Finland. Osteoporos Int. 2011;22(8):2307-312.Lindau TR, Aspenberg P, Arner M, Redlundh-Johnell I, Hagberg L. Fractures of the distal forearm in young adults. An epidemiologic description of 341 patients. Acta Orthop Scand. 1999;70(2):124-28.Diamantopoulos AP, Rohde G, Johnsrud I, Skoie IM, Hochberg M, Haugeberg G. The epidemiology of low- and high-energy distal radius fracture in middle-aged and elderly men and women in Southern Norway. PLoS One. 2012;7(8):e43367.Wilcke MK, Hammarberg H, Adolphson PY. Epidemiology and changed surgical treatment methods for fractures of the distal radius: a registry analysis of 42,583 patients in Stockholm County, Sweden, 2004–2010. Acta Orthop. 2013;84(3):292-96.Sigurdardottir K, Halldorsson S, Robertsson J. Epidemiology and treatment of distal radius fractures in Reykjavik, Iceland, in 2004. Comparison with an Icelandic study from 1985. Acta Orthop. 2011;82(4):494-98.Solgaard S, Petersen VS. Epidemiology of distal radius fractures. Acta Orthop Scand. 1985;56(5):391-93.Brogren E, Petranek M, Atroshi I. Incidence and characteristics of distal radius fractures in a southern Swedish region. BMC Musculoskelet Disord. 2007;8:48. Tsai CH, Muo CH, Fong YC, et al. A population-based study on trend in incidence of distal radial fractures in adults in Taiwan in 2000-2007. Osteoporos Int. 2011;22(11):2809-815.Koo OT, Tan DM, Chong AK. Distal radius fractures: an epidemiological review. Orthop Surg. 2013;5(3):209-13. Dóczi J, Renner A. Epidemiology of distal radius fractures in Budapest. A retrospective study of 2,241 cases in 1989. Acta Orthop Scand. 1994;65(4):432-33.Chen NC, Jupiter JB. Management of distal radial fractures. J Bone Joint Surg Am. 2007;89(9):2051-62.Pagano M, Gauvreau K. Princípios de Bioestatística. 2. ed. São Paulo: Pioneira Thompson Learning; 2004.                                  Court-Brown CM. Epidemiologia das fraturas e luxações. In: Court-Brown CM et al. (ed.); Fraturas em adultos de Rockwood Green. 8. ed. Barueri, SP: Manole; 2016.Fanuele J, Koval KJ, Lurie J, Zhou W, Tosteson A, Ring D. Distal radial fracture treatment: what you get may depend on your age and address. J Bone Joint Surg Am. 2009;91(6):1313-19.Jupiter JB, Marent-Huber M; LCP Study Group. Operative management of distal radial fractures with 2.4-millimeter locking plates: a multicenter prospective case series. Surgical technique. J Bone Joint Surg Am. 2010;92(Suppl 1 Pt 1):96-106.


2020 ◽  
Vol 3 (1) ◽  

Introduction: Distal radius fractures are one of the most common injuries which come to the orthopaedic surgeons. Displaced extra-or intra-articular fractures require anatomical reduction for a good outcome. Historically, these fractures were treated with manipulation and casting, with or without Kirschner (K) wire fixation. Modern plating techniques have been advocated to restore anatomical alignment and allow early mobilisation. Despite the wide variety of treatment options available there is still debate about the best way to treat these fractures. The aim of this study was to evaluate fifty cases of fracture distal end radius treated by open reduction and internal fixation using locking compression plating (LCP). Methods: The present study was carried out on 50 cases of acute fracture distal radius admitted at a tertiary care hospital treated by open reduction and internal fixation using locking compression plating (LCP) between January 2018 and December 2018. Functional results were rated at the end of the study as excellent, good or poor as criteria laid down by Gartland and Werley’s combined subjective and objective criteria. Results: 50 cases of fracture distal radius were selected for study that fulfill the inclusion criteria, were operated and studied. 10 fractures were fixed using Extra-articular Locking Compression T-Plates, 40 fractures were fixed using Juxtaarticular Locking Compression T-Plates. According to the Gartland and Werley’s rating scale, 20 had excellent results, 23 good results, and 07 fair results during latest follow up. Conclusion: Notwithstanding a very small sample size and a short follow up, Volar locking plate osteosynthesis at the distal radius signifies a significant improvement in the treatment of distal radial fractures in terms of restoration of the shape and function of the wrist.


Sign in / Sign up

Export Citation Format

Share Document