Influence of thermal insulation position in building envelope on the space cooling of high-rise residential buildings in Hong Kong

2001 ◽  
Vol 33 (6) ◽  
pp. 569-581 ◽  
Author(s):  
M Bojic ◽  
F Yik ◽  
P Sat
2014 ◽  
Vol 1025-1026 ◽  
pp. 1099-1102 ◽  
Author(s):  
Hae Kwon Jung ◽  
Ki Hyung Yu ◽  
Young Sun Jeong

Aapartment houses account for more than 60% of the total of residential buildings to be built in South Korea. In particular, a high-rise apartment house with 21 floors or more has steadily increased in densely populated areas. The heating and cooling energy demand of the apartment house is greatly affected by the shape and the thermal insulation of its building envelope. In addition to its functional efficiency, the shape of building envelope in a high-rise apartment house is considered to be an important factor for the urban landscape with diverse construction methods and materials. In this study, we analyzed the heating and cooling energy demand depending on the effective heat capacity of building structure and the installation position of thermal insulation materials as the design conditions of high-rise apartment houses. This study used the ECO2 energy analysis program for the building energy efficiency grading certification system in South Korea.


2014 ◽  
Vol 60 (3) ◽  
pp. 335-347
Author(s):  
A. Życzyńska ◽  
T. Cholewa

Abstract The energy saving tendencies, in reference to residential buildings, can be recently seen in Europe and in the world. Therefore, there are a lot of studies being conducted aiming to find technical solutions in order to improve the energy efficiency of existing, modernized, and also new buildings. However, there are obligatory solutions and requirements, which must be implemented during designing stage of the building envelope and its heating/cooling system. They are gathered in the national regulations. The paper describes the process of raising the energy standard of buildings between 1974–2021 in Poland. Therefore, the objective of this study is to show energy savings, which can be generated by modernization of thermal insulation of partitions of existing buildings and by the use of different ways of heat supply. The calculations are made on the selected multi-family buildings located in Poland, with the assumption of a 15 years payback time. It is shown that it is not possible to cover the costs of the modernization works by the projected savings with the compliance to the assumption of 15 years payback time.


Sign in / Sign up

Export Citation Format

Share Document