An electrochemical enrichment procedure for the determination of heavy metals by total-reflection X-ray fluorescence spectroscopy

1999 ◽  
Vol 54 (10) ◽  
pp. 1449-1454 ◽  
Author(s):  
A Ritschel ◽  
P Wobrauschek ◽  
E Chinea ◽  
F Grass ◽  
Ch Fabjan
2003 ◽  
Vol 107 ◽  
pp. 203-206 ◽  
Author(s):  
M. Bounakhla ◽  
A. Doukkali ◽  
K. Lalaoui ◽  
H. Aguenaou ◽  
N. Mokhtar ◽  
...  
Keyword(s):  

2018 ◽  
Vol 116 ◽  
pp. 233-237 ◽  
Author(s):  
Eleni Kamilari ◽  
Konstantinos Farsalinos ◽  
Konstantinos Poulas ◽  
Christos G. Kontoyannis ◽  
Malvina G. Orkoula

2020 ◽  
Vol 12 (40) ◽  
pp. 4899-4905
Author(s):  
Eva Marguí ◽  
Jerka Dumić ◽  
Ignasi Queralt ◽  
Lada Baković ◽  
Jasna Jablan

Trace elements are essential for the normal spermatogenesis of mammals and play a critical role in sperm quality and pathological processes e.g. inflammation..


2020 ◽  
Vol 2020 ◽  
pp. 1-9
Author(s):  
Blanca G. Beltrán ◽  
Victor Ramos-Sanchez ◽  
David Chávez-Flores ◽  
Rogelio Rodríguez-Maese ◽  
Edwin Palacio

Dietary supplements may contain heavy metals with the property of bioaccumulation in humans. The aim of this research was to validate and apply two analytical methods to determine Pb, As, Cr, and Hg in dietary supplements by Total Reflection X-ray Fluorescence Spectroscopy (TXRF). Methods validation was conducted through a multivariate analysis using a central composite design (CCD) and a desirability function. Critical values for each study variable were established. The TXRF_DS_1 method was proposed for Pb, As, and Cr determinations, while the TXRF_DS_2 was established for Hg analysis. The digestion method with an acid mixture (HNO3 + HCl + H2O2) was used to break down the organic material of dietary supplements. A solution of 10 μg L−1 Ga was used as an internal standard. Excellent analytical performance was obtained as LODs of 0.59, 0.41, 0.57, and 0.75 μg L−1 and LOQs of 1.95, 1.35, 1.90, and 2.50 μgL −1 for Pb, As, Cr, and Hg, respectively. Calibration curves showed a good linearity for all elements (R2>0.999). Excellent accuracy and precision in measurements (% RSD) was achieved. The real and spiked samples analysis demonstrated the applicability of the TXRF technique (percentage recovery 91–108%). Besides, two samples were analyzed in a comparison study between the TXRF_DS_1 method and the ICP-OES method. The results obtained showed good agreement between both techniques. The TXRF technique allows the analysis of toxic heavy metals in dietary supplements, which are marketed in a wide variety of presentations.


2015 ◽  
Vol 95 (13) ◽  
pp. 1208-1218 ◽  
Author(s):  
Rogerta Dalipi ◽  
Laura Borgese ◽  
Annalisa Zacco ◽  
Kouichi Tsuji ◽  
Emanuele Sangiorgi ◽  
...  

1991 ◽  
Vol 35 (B) ◽  
pp. 959-963 ◽  
Author(s):  
A. I. Egorov ◽  
L. P. Kablna ◽  
I. A. Kondurov ◽  
E. M. Korotkikh ◽  
V. V. Martynov ◽  
...  

The total reflection x-ray fluorescence (TXRF) method of analyzing elemental contents Is based on the small angle irradiation of thin samples placed on a total reflecting backing with a narrow photon beam. Two instrumental problems are to be solved here. The first is to form the narrow beam with a small angular deviation. The usual way to solve this problem is to use collimators with small solid angles. These angles must be less than the critical angle for x-ray total reflection, which, in the energy range 10 - 20 keV has an order of magnitude around 10−3 rad.


Sign in / Sign up

Export Citation Format

Share Document